• Title/Summary/Keyword: Vibration-damping

Search Result 2,147, Processing Time 0.03 seconds

Experiment on Vibration control of Beam using Active Constrained Layer Damping Treatment (능동구속감쇠 기법을 이용한 보의 진동제어 실험)

  • Choi, Jin-Young;Kang, Young-Kyu;Kim, Jae-Hwan;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.262-267
    • /
    • 2000
  • The flexural vibration of aluminum beams with active and passive constrained-layer damping has been investigated experimentally to design structure with maximum possible damping capacity. Piezoelectric film is used as sensor and piezoceramic as actuator for negative velocity feedback control. This paper shows the effectiveness of active constrained-layer damping treatment through experiment, and we have carried out an experiment to study effect of beam thickness.

  • PDF

Damping Ratio Evaluation Using Long-Term Ambient Vibration (장기간 상시계측을 통한 감쇠율 평가)

  • Kim, Yong Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The identification of damping ratios in buildings is a well-known problem and appears to be of important and crucial interest in the safety and serviceability design. When compared to an estimation of the stiffness, i.e. natural frequency, and mass, the damping ratio is the most difficult quantity to determine. Many previous studies have examined the characteristics of damping ratios from ambient vibration, but the measurement time is roughly within 2 hours. In this paper, characteristics of damping ratios and natural frequencies of 4 story RC building were investigated using long-term ambient vibration. Free vibrations were obtained using random decrement technique, and damping ratios were evaluated by the envelop function, continuous wavelet transform, and logarithmic decrement. It was found that although the natural frequencies show little variations with time, the damping ratios show some variations with time and the largest variations found in the damping ratios obtained from the continuous wavelet transform. The damping ratios from the envelop function showed the smallest mean and standard deviation. And the probability distribution of damping ratios seems to follow the logarithmic normal distribution.

Measurements of the vibration responses of CLD structures varied in thickness of the damping layer (제진층의 두께변화에 따른 CLD 구조의 진동응답 측정)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong;Kim, Seung-Joon;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1463-1466
    • /
    • 2007
  • Visco-elastic damping material for reducing heavy-weight floor impact noise and vibration in reinforced concrete structures was tested according to its thickness in the damping layer. The effect of damping material was compared with 20, 15, 10 and 5mm thickness. The wave propagation characteristics was measured for suggestion of an efficient method to reduce the floor impact noise. The method was proposed using the flexural wave propagation characteristics. The result showed that reduction of the thickness of damping layer made a slight difference; the natural frequency moved to higher frequency and the amplitude increased at low frequencies with 5mm thickness of damping material.

  • PDF

Power Flow Analysis of Vibration of a Plate Covered with a Damping Sheet (제진 평판 진동에 대한 파워흐름해석)

  • Lee, Jin-Young;Kil, Hyun-Gwon;Song, Jee-Hun;Hong, Suk-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.5
    • /
    • pp.530-536
    • /
    • 2009
  • In this paper, the power flow analysis(PFA) has been used to analyze the vibration of a plate covered with a damping sheet. Experiments have been performed to measure the loss factor and frequency response functions of the plate covered with the damping sheet. The data for the loss factor has been used as the input data to predict the vibration of the coupled plates with PFA. The comparison between the experimental results and the predicted PFA results for the frequency response functions has been performed. It showed that PFA can be effectively used to predict structural vibration of a plate covered with a damping sheet in medium-to-high frequency range.

Vibration Control of Smart Laminated Composite Plates Using Piezoceramic Sensor/Actuators and Viscoelastic Material (압전 세라믹 감지기/작동기와 점탄성 재료를 이용한 지능형 복합 적층판의 진동 제어)

  • 강영규;서경민;이시복
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.37-42
    • /
    • 2001
  • Active vibration control of laminated composite plates has been carried out to design structure with maximum possible damping capacity, using piezoceramic sensor/actuators and passive constrained-layer damping treatment. The equations of motion are derived for symmetrical, multi-layer laminated plates. The damping ratio(ζ) and modal damping(2ζ$\omega$) of the first bending and torsional modes are calculated by means of iterative complex eigensolution method for both passive and active vibration control. This paper addresses a design strategy of laminated composite plate under structural vibrations.

  • PDF

Application of Fe-Mn High Damping Alloys for Reduction of Noise and Vibration in Power Plants (Fe-Mn 방진합금을 적용한 발전소 격납용기 살수펌프의 소음$\cdot$진동 저감효과에 관한 연구)

  • 백승한
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.720-729
    • /
    • 1999
  • Coventional methods for reducing vibration in engineering designs (i.e. by stifferning or detuning) may be undesirable in conditions where size or weight must be minimized, or where complex vibration spectra exist. Some alloys with a combination of high damping capacity and good mechanical properties can provide attractive techanical and economical solutions to problems involving seismic, shock and vibration isolation. Although several non ferrous damping alloys have been developed, none of those materials are applied in any industrial factor due largely to high production cost. To meet these requirement, we have developed a new Fe-Mn high damping alloy. In previous studies, we have reported that an Fe-17%Mn alloy exhibits the highest damping capacity(Specific Damping Capacity:SDC, 30%) among Fe-Mn binary system, and proposed that the boundaries of various types such as $\varepsilon$-martensite variant boundaries, stacking faults in $\varepsilon$-martensite, stacking faults in austenitic and ${\gamma}$$\gamma /\varepsilon$ interfaces give rise to a high damping capacity. The Fe-17%Mn alloy also has advantages of good mechanical properties(T.S. 70 kg/nm$^2$ and low cost over other damping alloys(1/4 times the cost of non-ferrous damping alloy). Thus, the Fe-17%Mn high damping alloy can be widely applied to household appliances, automobiles, industrial facilities and power plant components. In this paper, the overall properties of the Fe-17%Mn high damping alloy is introduced, and its applicability to containment spray pump in the power plant is discussed.

  • PDF

Study on the Analysis Process of the Damping Material for Reduced Floor Vibration (플로워 진동 저감을 위한 제진재 해석 프로세스 연구)

  • Kim, Ki-Chang;Hwang, Mi-Kyong;Seo, Seong-Hoon;Choi, Ja-Min;Kim, Chan-Mook;Kim, Jin-Taek
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.333-338
    • /
    • 2011
  • This paper describes the design process of floor damping material optimization to reduce structure borne noise. This process uses finite element analysis(FEA) along with experimental techniques to complement each other. The objective of this approach was to develop an optimized damping material application layout and thickness at the initial design stage. The first step is to find the sensitivity areas of vehicle body without damping material applied using FEA. In order to determine the high vibration areas of the floor panel, the velocity was measured using a scanning laser vibrometer from 20 Hz to 300 Hz. To excite the floor panel vibration, shaker was placed at the front suspension attachment point. The second step is the optimization process to determine the light weight solution of damping material. The design guideline of damping material was suggested that the lightweight solution was verified using test result of road noise. Design engineer could efficiently decide the design variable of damping material using parameter analysis results in early design stage.

The Study on the improvement of dynamic characteristics with multi-orifice in airspring (멀티 오리피스를 이용한 에어스프링 동특성 개선에 관한 연구)

  • 김인수;황성호;한문성;고철수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.97-103
    • /
    • 2002
  • Vibration isolation technology using an air spring and laminated rubber bearing is widely used because it has excellent vibration isolation characteristics. In the part of that, we usually make use of the self-damped air suing. It is occupied two chambers, restrictor, diaphragm and load plate. Two chambers contain compressed air and the volume of chambers and the area of load plate give a definition of stiffness and load. The restrictor and the volume ratio of two chambers give a definition of damping ratio. The conventional model of restrictor is made of one orifice and it causes turbulent flow in the orifice at the region of large deflection. The stillness of air suing is larger and the damping is lower in the region of large deflection. In the multi-orifice case, the stiffness is similar to air spring with one orifice but damping ratio is larger than conventional air spring. And damping ratio is smaller than conventional air suing in small deflection region. Deflection is small in the region of high frequency so small damping is better than large damping. As a result, we can reduce the storage stiffness of air suing in the wide region of deflection and increase the damping ratio in the region of large deflection. After this, we will try to and the relation of Reynolds Number and Flow Resistance then we are going to make another restrictor for air spring to improve damping ratio and stiffness.

  • PDF

Control of Damping Coefficients for the Shear Mode MR Dampers Using Inverse Model (역모델을 이용한 MR 댐퍼의 감쇠계수 제어)

  • Na, Uhn Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.445-455
    • /
    • 2013
  • A new linearization model for MR dampers is analyzed. The nonlinear hysteretic damping force model of MR damper can be modeled as a hyperbolic tangent function of currents, positions, and velicities, which is an algebraic function with constant parameters. Model parameters can be identified with numerical method using experimental force-velocity-position data obtained from various operating conditions. The nonlinear hysteretic damping force can be linearized with a given slope of damping coefficient if there exist corresponding currents to compensate for the nonlinearity. The corresponding currents can be calculated from the inverse model when the given linear damping force is set equal to the nonlinear hysteretic damping force. The linearization controller is realized in a DSP controller such that the corresponding currents to satisfy a given damping coefficient should be calculated. Experiments show that the current inputs to the MR damper produce linearized damping force with a given slope of the damping coefficient.

Compound damping cable system for vibration control of high-rise structures

  • Yu, Jianda;Feng, Zhouquan;Zhang, Xiangqi;Sun, Hongxin;Peng, Jian
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.641-652
    • /
    • 2022
  • High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.