• 제목/요약/키워드: Vibration absorption

검색결과 407건 처리시간 0.026초

흡음재가 조합된 헬름홀츠 공명기의 흡음성능 (Sound Absorption Performance of a Helmholtz Resonator combined with Porous Materials)

  • 이영철;이선기;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.280-285
    • /
    • 2008
  • The helmholtz resonator with the perforated neck has demerits that the absorption performance is not so outstanding in an anti-resonance frequency and high frequency bandwidth. In order to overcome these problems, in the paper, a resonator combined with porous material is proposed. The absorption performances of resonators are measured by two-microphone method and estimated by transfer matrix method. The experimentally measured values of normal absorption coefficients agree well with the corresponding values from the transfer matrix method. Because of the porous material, it is shown that the absorption performance have been significantly improved in the anti-resonance frequency and high frequency bandwidth.

  • PDF

다공판 시스템의 흡음성능에 유동이 미치는 영향 (The effect of the flow on the absorption performance of a perforated plate system)

  • 허성욱;제현수;양수영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.879-884
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow and grazing-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, grazing-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that for the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but fur the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

건축내장재의 흡음 특성 (Absorption Characteristics of Building Interior Decoration Materials)

  • 강대준;이재원;이우석;홍준기;조윤희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1190-1193
    • /
    • 2006
  • It is important to consider absorption characteristics of building interior decoration materials when we design a building and simulate acoustics in a room. The purpose of this study is to accumulate acoustic data on building interior decoration materials and give a basic data for improving absorption performance by testing absorption coefficient of 9 types of ceiling materials, 14 types of wall paper and 20 types of floor papers.

  • PDF

다중 다공판 시스템의 흡음성능 향상에 관한 연구 (A Study on the Improvement of Acoustic Absorption of Multiple Layer Perforated Panel Systems)

  • 이동훈;서성원;홍병국;송화영
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.571-577
    • /
    • 2005
  • The acoustic absorption of multiple layer perforated panel systems is largely reduced at the anti-resonance frequency. In order to improve the acoustic absorption at the anti-resonance frequency, the sound absorbing materials are inserted between perforated panels. By the insertion of absorbing materials, it is found that the multiple layer perforated panel system has better acoustic absorption at the anti-resonance frequency and more broadband frequency. Besides, it is shown that the absorption coefficients from the transfer matrix method agree well with the values measured by the two-microphone impedance tube method for various combinations of perforated panels, airspaces or sound absorbing materials.

흡음재가 조합된 헬름홀츠 공명기의 흡음성능에 관한 연구 (A Study on the Sound Absorption Performance of a Helmholtz Resonator Combined with Porous Materials)

  • 이동훈;송화영
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.628-633
    • /
    • 2009
  • The helmholtz resonator with the perforated neck has demerits that the absorption performance is not so outstanding in an anti-resonance frequency and high frequency bandwidth. In order to overcome these problems, in the paper, a resonator combined with porous material is proposed. The absorption performances of resonators are measured by two-microphone method and estimated by transfer matrix method. The experimentally measured values of normal absorption coefficients agree well with the corresponding values from the transfer matrix method. Because of the porous material, it is shown that the absorption performance have been significantly improved in the anti-resonance frequency and high frequency bandwidth.

다공판 시스템의 흡음성능에 관통유동이 미치는 효과 (Effect of the through-flow on the absorption performance of a perforated plate system)

  • 허성욱;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.163-167
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that fur the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but for the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

빔형성방법을 이용한 흡음계수 측정법 (Measurement of absorption coefficient using beamforming method)

  • Ju, Hyung-Jun;Kang, Yeon-June
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.370.1-370
    • /
    • 2002
  • A method using beamforming has been developed to measure absorption coefncient of oblique incidence. MUSIC(Multiple Signal Classification) method detects the angle of incidence and reflection. And beamforming method separates the incident and reflected wave. And spatial smoothing technique is used to reduce the coherence between the incident and reflected wave. The test material were modeled as a locally reacting surface. Numerical and experiment results are performed to verify the performance of proposed method.

  • PDF

잔향실의 음장해석 (II) (Analysis of the Sound field in a Reverberation Room(II))

  • 임정빈;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.681-686
    • /
    • 1997
  • Foamed aluminum is well known metallic porous sound absorption material which has excellent properties of light weight and high absorbing performance. For the purpose of finding out the sound field characteristics within a simple closed cubic enclosure with foamed aluminum, analytic and experimental studies are performed. For the first time, the standing wave apparatus is used to measure absorption coefficient and impedance of the foamed aluminum. Next, the sound effects of absorption material in acoustically loaded rectangular enclosure are identified according as the foamed aluminim is to be or not.

  • PDF

축척모형을 활용한 개방형 천장의 흡음률 측정 (Measurements of absorption coefficients of open-type ceilings using 1:25 scale model reverberation chamber)

  • 이혜미;김용희;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.683-686
    • /
    • 2007
  • This paper investigates acoustical characteristics of open-type ceilings using 1:25 scale model. The field survey in the existing 15 halls was carried out to figure out the ceiling structure. The components of the open-type ceiling were mainly steel truss structures, duct, catwalk and finishing surfaces. In order to investigate the absorption characteristics of the equipped ceiling, the absorption coefficient measurements were made using 1:25 reverberation chamber based on ISO 354. Results showed that the absorption coefficient of the empty ceiling structure (6m-height) with 50%-perforated covering plate was 0.2-0.3 at above 500 Hz. When steel structure was added inside the empty ceiling, absorption coefficient increased by 0.16 at 250-1kHz. Adding catwalk did not increase the absorption, but adding duct increased the absorption at 1-2kHz. NRC of the equipped ceiling was 0.39, and the absorption characteristics were mainly found at high frequencies. In addition, the opening size of the covering plate did not change the absorption coefficient of the equipped ceiling meaningfully.

  • PDF