• 제목/요약/키워드: Vibration absorption

검색결과 409건 처리시간 0.03초

타공형태에 따른 다중 다공판 시스템의 흡음률 변화 (Effect of the perforation shape on the absorption coefficient of multi-layer absorbing system)

  • 강준구;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1202-1204
    • /
    • 2006
  • Various types of perforated sheets have been applied on the surface of porous absorptive materials in order to protect dust and to enhance interior design. This study examines experimentally influences on absorptive characteristics according to the shape of perforation which includes rectangular and resonator type as well as circular holes. The measured results shows that the resonance frequency can be changed by the shape of perforation as well as the eccentricity of holes.

  • PDF

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Sound Barrier)

  • 허영;김홍식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF

경량콘크리트 패널의 차음성능에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance for Light-weight Concrete Panel)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.457-460
    • /
    • 2004
  • This study examines the sound insulation of the light-weight wall using light-weight concrete and offers the basic datum for enhancing it. The sound insulation of the light-weight wall is determinated by the density, installation method, absorption materials, air layers etc. Among the factors, the solution of outlet that is the major cause of reducing sound insulation should be made. If absorption materials are installed in the cavity walls, it enhances to 15dB in 500Hz.

  • PDF

터보 냉동기의 소음원 파악 및 저소음화에 대한 연구 (A Study on the identification of the noise source and noise reduction method of turbo chiller)

  • 전완호;이준근;정필중;염창훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.125-131
    • /
    • 2000
  • The turbo chiller uses centrifugal compressor, which operates at about 14500 rpm. Due to the high rpm of the impeller, the noise of chiller makes one of the serious problems. The possibility of the sound reduction by using absorbing material is studied in this paper. The generated sound propagates through the duct and then radiates to the outer field. So, the use of sound absorption material inside the duct is one of the effective methods. To study the effect of location of the material, we use Boundary Element Method to analyze the sound field inside the duct system. Numerical study shows the highest sound pressure region is near the elbow of curved duct. From the analysis, it is also shown that the elbow duct is the main radiator of noise and sound absorption treatment of this duct results noise reduction of the highest noise level at BPF and high frequency region.

  • PDF

덕트형 소음기 설계 프로그램 개발 (Development of Design Program for Duct Silencer)

  • 김인수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.379-383
    • /
    • 2000
  • This paper describes the design program of duct silencer. Duct silencer is used ventilating system. Variables in the program for predicting transmission loss are width of splitter, airway width, perforate plate, absorption material and frequency. Generally used expression for predicting transmission loss has something that don't think about frequency characteristic. Therefore we propose the new expression that considered frequency characteristic. In the 1/1 octave band center frequency, the expected weighting number(K) is fitted with absorption ratio and airway width. The fitted 2nd degree polynomial expression is based on the test data performed in YOUIL Industrial Corperation. This program's accuracy is about 90 percent.

  • PDF

Surface Modification of Silica Spheres for Copper Removal

  • Kim, Byoung-Ju;Park, Eun-Hye;Kang, Kwang-Sun
    • 대한화학회지
    • /
    • 제60권5호
    • /
    • pp.317-320
    • /
    • 2016
  • Efficient copper removal from water was achieved by using surface modified silica spheres with 3-mercaptopropyltrimethoxysilane (MPTMS) using base catalyst. The surface modification of silica spheres was performed by hydrolysis and condensation reactions of the MPTMS. The characteristic infrared absorption peaks at 2929, 1454, and 1343 cm−1 represent the −CH2 stretching vibration, asymmetric deformation, and deformation, respectively. The absorption peaks at 2580 and 693 cm−1 corresponding the −SH stretching vibration and the C-S stretching vibration indicate the incorporation of MPTMS to the surface of silica spheres. Field emission scanning electron microscope (FESEM) image of the surface modified silica sphere (SMSS) shows nano-particles of MPTMS on the surface of silica spheres. High concentration of copper solution (1000 ppm) was used to test the copper removal efficiency and uptake capacity. The FESEM image of SMSS treated with the copper solution shows large number of copper lumps on the surface of SMSS. The copper concentration drastically decreased with increasing the amount of SMSS. The residual copper concentrations were analyzed using inductively coupled plasma mass spectrometer. The copper removal efficiency and uptake capacity with 1000 ppm of copper solution were 99.99 % and 125 mg/g, respectively.

음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어 (Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity)

  • 강성우;한윤식;황태연;손영;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

천장 및 벽구성 방법에 따른 바닥충격음 특성평가 (Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

전달행렬법에 의한 다공질 흡음재의 음향특성 연구 (A Study on the Acoustic Properties of Porous Material by Using Acoustic Transfer Matrix)

  • 박철희;주재만;염창훈
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.635-644
    • /
    • 1996
  • In this paper, Allard's modelling method which employs the method of acoustic transfer matrix(ATM) is applied to yield more precise results in the analysis of porous sound absorbing material. The method of ATM, based on Biot's theory, is known to play an important role in the estimation of the sound absorption when a sound projects onto the material. In the case of a single layered porous sound absorbing material, the surface impedance and the absorption coefficient by using the method of ATM are estimated. With the variation of the material properties, sound absorption characteristics and analyzed. Transmission Loss in a combination of the porous sound absorbing material with a thin plate is predicted.

  • PDF

확산형 흡수식 냉장고의 사이클 해석 (Cycle Analysis of Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.