• Title/Summary/Keyword: Vibration Filter

Search Result 385, Processing Time 0.026 seconds

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

Particle displacement distributions of energy-trapped thickness shear vibrations in the piezoelectric substrate (압전체 기판에서 에너지 포획된 두께 전단진동의 변위분포)

  • 이개명
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.954-963
    • /
    • 1996
  • Particle displacement distributions of the fundamental thickness shear vibration mode and overtone modes in an energy-trapped single resonator and an energy-trapped double acoustically coupled filter were calculated. The effects of the width of a pair of partial eletrodes and the magnitude of the plate back of the resonator on the particle displacement distributions of its symmetric vibration mode and anti-symmetric vibration mode were investigated. And the effects of the width of a pair of partial eletrodes, the width of the gap between two pairs of partial electrodes and the magnitude of the plate back of the filter on the particle displacement distributions of its symmetric vibration mode and anti-symmetric vibration mode were investigated.

  • PDF

Sliding Mode Fuzzy Control for Wind Vibration Control of Tall Building (Sliding Mode Fuzzy Control을 사용한 바람에 의한 대형 구조물의 진동제어)

  • 김상범;윤정방
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.79-83
    • /
    • 2000
  • A sliding mode fuzzy control (SMFC) with disturbance estimator is applied to design a controller for the third generation benchmark problem on an wind-excited building. A distinctive feature in vibration control of large civil infrastructure is the existence of large disturbances, such as wind, earthquake, and sea wave forces. Those disturbances govern the behavior of the structure, however, they cannot be precisely measured, especially for the case of wind-induced vibration control. Since the structural accelerations are measured only at a limited number of locations without the measurement of the wind forces, the structure of the conventional control may have the feed-back loop only. General structure of the SMFC is composed of a compensation part and a convergent part. The compensation part prevents the system diverge, and the convergent part makes the system converge to the sliding surface. The compensation part uses not only the structural response measurement but also the disturbance measurement, so the SMFC has a feed-back loop and a feed-forward loop. To realize the virtual feed-forward loop for the wind-induced vibration control, disturbance estimation filter is introduced. the structure of the filter is constructed based on an auto regressive model for the stochastic wind force. This filter estimates the wind force at each time instance based on the measured structural responses and the stochastic information of the wind force. For the verification of the proposed algorithm, a numerical simulation is carried out on the benchmark problem of a wind-excited building. The results indicate that the present control algorithm is very efficient for reducing the wind-induced vibration and that the performance indices improve as the filter for wind force estimation is employed.

  • PDF

Design of a Wavelet Filter for Experimental Error Improvement on Acoustic Decay Measurements (음 감쇠 측정에서 측정 오차 개선을 위한 웨이블렛 필터 설계)

  • 이민성;이상권;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.991-996
    • /
    • 2001
  • It is well known that there are two experimental errors on acoustic decay measurements. One is due to the influence of the band pass filter the other one is that of an averaging device. In this paper the influence of the filter is in detail investigated. To minimize the influence of filter, the product of the filter bandwidth Β (3㏈ bandwidth) and the reverberation time T$\sub$60/ of the room under test is at least 16. Moreover, if the initial part of an acoustic decay curve is important, the strong requirement, i.e. BT$\sub$60/> 64, must be satisfied. In this paper, the wavelet filter bank instead of the band pass filter bank is applied to obtain an acoustic decay curve. As results, the influence of filter is reduced and then the value of BT$\sub$60/ required for obtaining an acceptable decay curve is at least 4. The strong requirement for the initial part of a decay curve is also replaced by the BT$\sub$60/> 16 instead of BT$\sub$60/> 64.

  • PDF

Vibration Control of the 2 Axial Overhead Crane by Input Shaping Method Using Digital IIR Filter (디지털 IIR 필터를 이용한 입력성형기법에 의한 2축 천정크레인의 진동제어)

  • Noh, Sang-Hyun;Park, Un-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • Input shaping technique has been used as a simple method of controlling vibration. With the conventional methods previously proposed by several authors, the frequency range that shows a good performance is restricted. When the designed frequency being different from the natural frequency of a system, the performance of control degrades remarkably. This paper introduced a new technique that uses digital IIR filter to control vibration. This technique has robustness for changing of parameter. In order to prove this we applied input shaping method to 2 axial overhead crane.

  • PDF

Measurement of Reverberation Times in the Compartment of Vehicles Using Wavelet Filter Bank (웨이블렛 필터를 이용한 자동차 실내공간의 잔향시간 측정에 관한 연구)

  • 이상권;유동준;이승영;박동철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.111-118
    • /
    • 2004
  • A number of researchers have attempted to measure the reverberation time of a passenger car, ut the reverberation time of passenger car is too short to measure with the traditional band pass filter. And if the reverberation time is very short, the product of the reverberation time (T) and the bandwidth (B) of the traditional band pass fitter becomes small. The low limit of BT product required for the measurement of reverberation time with the traditional band pass filter is 16. In order to overcome this problem, the wavelet filter bank was developed. In this study, this new wavelet filter was employed to measure the reverberation times of five different classes of passenger cars. The low limit of BT product required for the measurement of reverberation time with the wavelet filter is 4. The reverberation times of five passenger cars were measured successfully with the new wavelet filter bank. The reverberation times measured in most passenger cars was found to be around 0.04. Compared with general acoustic rooms like concert halls, this is a very short reverberation time

Active Vibration Control of A Time-Varying Cantilever Beam Using Band Pass Filters and Artificial Neural Network (신경회로망과 능동대역필터를 이용한 시변 외팔보 능동 진동제어)

  • Hamm, Gil;Rhee, Huinam;Yoon, Doo Byung;Han, Soon Woo;Park, Jin Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.353-354
    • /
    • 2014
  • An active vibration control technique of a time-varying cantilever beam is proposed in this study. A simple in-house coil sensor instead of expensive commercial sensors was used to measure the vibrational displacement of the beam. Active band pass filters and artificial neutral net works detect the frequencies, amplitudes, and phases of the main vibration mode. The time constants of the low pass filter representing the positive position feedback controller are updated in real-time, which generates the control voltage input to actuate the piezoelectric actuator and suppress the vibration. An experiment was successfully performed to verify the algorithm for a cantilever beam, which fundamental natural frequency arbitrarily varies between 9 Hz ~ 18 Hz. The present active vibration suppression technique can be applied to variety of structures which undergoes large variation of dynamic characteristics while operating.

  • PDF

A new approach to deal with sensor errors in structural controls with MR damper

  • Wang, Han;Li, Luyu;Song, Gangbing;Dabney, James B.;Harman, Thomas L.
    • Smart Structures and Systems
    • /
    • v.16 no.2
    • /
    • pp.329-345
    • /
    • 2015
  • As commonly known, sensor errors and faulty signals may potentially lead structures in vibration to catastrophic failures. This paper presents a new approach to deal with sensor errors/faults in vibration control of structures by using the Fault detection and isolation (FDI) technique. To demonstrate the effectiveness of the approach, a space truss structure with semi-active devices such as Magneto-Rheological (MR) damper is used as an example. To address the problem, a Linear Matrix Inequality (LMI) based fixed-order $H_{\infty}$ FDI filter is introduced and designed. Modeling errors are treated as uncertainties in the FDI filter design to verify the robustness of the proposed FDI filter. Furthermore, an innovative Fuzzy Fault Tolerant Controller (FFTC) has been developed for this space truss structure model to preserve the pre-specified performance in the presence of sensor errors or faults. Simulation results have demonstrated that the proposed FDI filter is capable of detecting and isolating sensor errors/faults and actuator faults e.g., accelerometers and MR dampers, and the proposed FFTC can maintain the structural vibration suppression in faulty conditions.

Empirical mode decomposition based on Fourier transform and band-pass filter

  • Chen, Zheng-Shou;Rhee, Shin Hyung;Liu, Gui-Lin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.939-951
    • /
    • 2019
  • A novel empirical mode decomposition strategy based on Fourier transform and band-pass filter techniques, contributing to efficient instantaneous vibration analyses, is developed in this study. Two key improvements are proposed. The first is associated with the adoption of a band-pass filter technique for intrinsic mode function sifting. The primary characteristic of decomposed components is that their bandwidths do not overlap in the frequency domain. The second improvement concerns an attempt to design narrowband constraints as the essential requirements for intrinsic mode function to make it physically meaningful. Because all decomposed components are generated with respect to their intrinsic narrow bandwidth and strict sifting from high to low frequencies successively, they are orthogonal to each other and are thus suitable for an instantaneous frequency analysis. The direct Hilbert spectrum is employed to illustrate the instantaneous time-frequency-energy distribution. Commendable agreement between the illustrations of the proposed direct Hilbert spectrum and the traditional Fourier spectrum was observed. This method provides robust identifications of vibration modes embedded in vibration processes, deemed to be an efficient means to obtain valuable instantaneous information.

Noisy Time Varying Vibration Signal Analysis using Adaptive Predictor-Binary Tree Structured Filter Bank System (적응예측기-이진트리구조 필터뱅크 시스템을 이용한 잡음이 부가된 시변 진동신호 분석)

  • Bae, Hyeon-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Generally, a time-varying vibration signal is generated in a rotating machine system, and when there is a failure in the rotating machine, the signal contains noise. In this paper, we propose a system consisting of an adaptive predictor and a binary tree filter bank for analyzing time - varying vibration signals with noise. And the vibration signal analyzed results in this system is used for fault diagnosis of the rotating machine. The adaptive predictor of the proposed system predicts the periodic signal components, and the filter bank system decomposes the difference signal between the input signal and the predicted periodic signal into subband. Since each subband signal includes a noise signal component due to a failure, it is possible to diagnose the failure of the using rotary machine. The validity of the proposed vibration signal analysis method is shown in the simulations, where the periodic components cancelled vibrating signals are decomposed to 32 subband, and the signal characteristics related faults are analyzed.