• Title/Summary/Keyword: Vessel extraction

Search Result 66, Processing Time 0.029 seconds

An Effective Retinal Vessel and Landmark Detection Algorithm in RGB images

  • Jung Eun-Hwa
    • International Journal of Contents
    • /
    • v.2 no.3
    • /
    • pp.27-32
    • /
    • 2006
  • We present an effective algorithm for automatic tracing of retinal vessel structure and vascular landmark extraction of bifurcations and ending points. In this paper we deal with vascular patterns from RGB images for personal identification. Vessel tracing algorithms are of interest in a variety of biometric and medical application such as personal identification, biometrics, and ophthalmic disorders like vessel change detection. However eye surface vasculature tracing in RGB images has many problems which are subject to improper illumination, glare, fade-out, shadow and artifacts arising from reflection, refraction, and dispersion. The proposed algorithm on vascular tracing employs multi-stage processing of ten-layers as followings: Image Acquisition, Image Enhancement by gray scale retinal image enhancement, reducing background artifact and illuminations and removing interlacing minute characteristics of vessels, Vascular Structure Extraction by connecting broken vessels, extracting vascular structure using eight directional information, and extracting retinal vascular structure, and Vascular Landmark Extraction by extracting bifurcations and ending points. The results of automatic retinal vessel extraction using jive different thresholds applied 34 eye images are presented. The results of vasculature tracing algorithm shows that the suggested algorithm can obtain not only robust and accurate vessel tracing but also vascular landmarks according to thresholds.

  • PDF

Pulmonary Vessel Extraction and Nodule Reclassification Method Using Chest CT Images (흉부 CT 영상을 이용한 폐 혈관 추출 및 폐 결절 재분류 기법)

  • Kim, Hyun-Soo;Peng, Shao-Hu;Muzzammil, Khairul;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.35-43
    • /
    • 2009
  • In the Computer Aided Diagnosis(CAD) System, the efficient way of classifying nodules from chest CT images of a patient is to perform the classification of the remaining part after the pulmonary vessel extraction. During the pulmonary vessel extraction, due to the small difference between the vessel and nodule features in imaging studies such as CT scans after having an injection of contrast, nodule maybe extracted along with the pulmonary vessel. Therefore, the pulmonary vessel extraction method plays an important role in the nodule classification process. In this paper, we propose a nodule reclassification method based on vessel thickness analysis. The proposed method consist of four steps, lung region searching step, vessel extraction and thinning step, vessel topology formation and correction step and the reclassification of nodule in the vessel candidate step. The radiologists helped us to compare the accuracy of the CAD system using the proposed method and the accuracy of general one. Experimental results show that the proposed method can extract pulmonary vessels and reclassify false-positive nodules accurately.

Development of the Sample Pretreatment Technique using Microwave for Analysis of Insecticide Imidacloprid Residues (마이크로파를 이용한 잔류 살충제 Imidacloprid 분석용 시료전처리 기술개발)

  • Ahn, S.Y.;Cho, H.K.;Lee, E.Y.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.121-129
    • /
    • 2007
  • This study was conducted to elucidate extraction efficiency by microwave technique in comparison with sonication technique for extraction of insecticide residue in pear. In the analysis of the extraction efficiency of microwave for a pear spiked with imidacloprid, the extraction efficiency by microwave power of 300 W with extraction temperature of $80^{\circ}C$, heating time of 1 to 3 minute was shown to be similar with the extraction time 20 minutes by sonication. The optimal condition. in consideration of economical condition and treatment time, for microwave extraction of imidacloprid in the pear were 300 watts of power supply, $100^{\circ}C$ of extraction temperature, 1 minute of heating time and 10 mL of acetone volume. A new microwave vessel was developed to rapidly process the sample of the insecticide imidacloprid residues in the pear. This vessel was designed to include a reaction chamber and a filtration equipment, and a gathering chamber. The system could curtail a pretreatment time to 21 minutes than sonication and 7.9 minutes than the previous microwave vessel.

Thermodynamic Analysis of the Extraction Process and the Cold Energy Utilization of LNG (LNG추출과정과 냉열이용의 열역학적 해석)

  • Lee, G.S.;Chang, Y.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.120-131
    • /
    • 1995
  • Thermodynamic analysis of extraction process from the constant pressure LNG(Liquefied Natural Gas) vessel was performed in this study. LNG was assumed as a binary mixture of 90% methane and 10% ethane by mole fraction. The thermodynamic properties such as temperature, composition, specific volume and the amount of cold energy were predicted during extraction process. Pressure as a parameter ranges from 101.3kPa to 2000kPa. The result shows the peculiar phenomena for the LNG as a mixture. Both vapor and liquid extraction processes were investigated by a computer model. The property changes are negligible in the liquid extraction process. For the vapor extraction process, the temperature in the vessel increases rapidly and the extracted composition of methane decreases rapidly near the end of extracting process. Specific volume of vapor has the maximum and that of liquid has the minimum during the process. When pressure is increased, specific volume of vapor decreases and that of liquid increases. It was found that specific volume of vapor phase had a major effect on the heat absorption at constant pressure during vapor extraction process. If the pressure of the vessel increases, the total cold energy which can be utilized from LNG decreased.

  • PDF

Edge Extraction using Fuzzy Techniques in Coronary Artery Image (Fuzzy 기법을 이용한 관상동맥영상의 에지추출)

  • Kim, Seong-Hu;Lee, Ju-Won;Kim, Joo-Ho;Lee, Han-Wook;Jung, Won-Geun;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.585-590
    • /
    • 2012
  • Coronary Intervention treatment has become the core that is the test of cardiac catheterization to conduct treatment with Coronary Arteriography. Operators must be careful in Coronary Intervention treatment because the stent is inserted into the point of narrowing of blood vessel. So, the operator must correctly recognize the path of blood vessel to deal with the problems which are damages and ruptures of blood vessel, and there would be some errors of finding the path of blood vessel by bad qualify of the image. Therefore in this paper, median filtering is conducted by preprocessing to evaluate the performance of the effect of noise of the image that affects quality of the image and Fuzzy Edge Extraction Techniques is tested by using Soble Edge Extraction Techniques to compare the performance with The Fuzzy Edge Extraction Techniques. In result, the performance, removing the noise and extracting the signal of Fuzzy Edge Extraction Techniques using median filtering, demonstrates the superiority.

A study on visual tracking of the underwater mobile robot for nuclear reactor vessel inspection

  • Cho, Jai-Wan;Kim, Chang-Hoi;Choi, Young-Soo;Seo, Yong-Chil;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1244-1248
    • /
    • 2003
  • This paper describes visual tracking procedure of the underwater mobile robot for nuclear reactor vessel inspection, which is required to find the foreign objects such as loose parts. The yellowish underwater robot body tends to present a big contrast to boron solute cold water of nuclear reactor vessel, tinged with indigo by Cerenkov effect. In this paper, we have found and tracked the positions of underwater mobile robot using the two color information, yellow and indigo. The center coordinates extraction procedures are as follows. The first step is to segment the underwater robot body to cold water with indigo background. From the RGB color components of the entire monitoring image taken with the color CCD camera, we have selected the red color component. In the selected red image, we extracted the positions of the underwater mobile robot using the following process sequences; binarization, labelling, and centroid extraction techniques. In the experiment carried out at the Youngkwang unit 5 nuclear reactor vessel, we have tracked the center positions of the underwater robot submerged near the cold leg and the hot leg way, which is fathomed to 10m deep in depth.

  • PDF

Ultrasound-Assisted Extraction of Canola Oil Using Supercritical Fluid Process (초음파가 적용된 초임계 유체 공정을 이용한 캐놀라오일 추출)

  • Hwang, Ah-Reum;Lim, Gio-Bin;Ryu, Jong-Hoon
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.437-442
    • /
    • 2010
  • The objective of this study was to investigate the effect of ultrasound on the extraction of oil from canola seeds when supercritical carbon dioxide ($SCCO_2$) was used as an extraction solvent. The ultrasound-assisted $SCCO_2$ extraction were carried out while varying such operating parameters as particle size of crushed canola seed, flow rate of $SCCO_2$, aspect ratio of the extraction vessel, and ultrasound power. The extraction rate decreased with increasing particle size of samples, showing a maximun at a $CO_2$ flow rate of 6.2 L/min. Both the extraction rate and extraction yield increased with a decrease in the aspect ratio of the extraction vessel. For the ultrasoundassisted $SCCO_2$ extraction, the extraction yield was slightly increased when the $CO_2$ flow rate was below 6 mL/min with sample A and B.

Automatic Lower Extremity Vessel Extraction based on Bone Elimination Technique in CT Angiography Images (CT 혈관 조영 영상에서 뼈 소거법 기반의 하지 혈관 자동 추출)

  • Kim, Soo-Kyung;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.12
    • /
    • pp.967-976
    • /
    • 2009
  • In this paper, we propose an automatic lower extremity vessel extraction based on rigid registration and bone elimination techniques in CT and CT angiography images. First, automatic partitioning of the lower extremity based on the anatomy is proposed to consider the local movement of the bone. Second, rigid registration based on distance map is performed to estimate the movement of the bone between CT and CT angiography images. Third, bone elimination and vessel masking techniques are proposed to remove bones in CT angiography image and to prevent the vessel near to bone from eroding. Fourth, post-processing based on vessel tracking is proposed to reduce the effect of misalignment and noises like a cartilage. For the evaluation of our method, we performed the visual inspection, accuracy measures and processing time. For visual inspection, the results of applying general subtraction, registered subtraction and proposed method are compared using volume rendering and maximum intensity projection. For accuracy evaluation, intensity distributions of CT angiography image, subtraction based method and proposed method are analyzed. Experimental result shows that bones are accurately eliminated and vessels are robustly extracted without the loss of other structure. The total processing time of thirteen patient datasets was 40 seconds on average.

Position Tracking of Underwater Robot for Nuclear Reactor Inspection using Color Information (색상정보를 이용한 원자로 육안검사용 수중로봇의 위치 추적)

  • 조재완;김창회;서용칠;최영수;김승호
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2259-2262
    • /
    • 2003
  • This paper describes visual tracking procedure of the underwater mobile robot for nuclear reactor vessel inspection, which is required to find the foreign objects such as loose parts. The yellowish underwater robot body tend to present a big contrast to boron solute cold water of nuclear reactor vessel, tinged with indigo by Cerenkov effect. In this paper, we have found and tracked the positions of underwater mobile robot using the two color informations, yellow and indigo. The center coordinates extraction procedures is as follows. The first step is to segment the underwater robot body to cold water with indigo background. From the RGB color components of the entire monitoring image taken with the color CCD camera, we have selected the red color component. In the selected red image, we extracted the positions of the underwater mobile robot using the following process sequences: binarization labelling, and centroid extraction techniques. In the experiment carried out at the Youngkwang unit 5 nuclear reactor vessel, we have tracked the center positions of the underwater robot submerged near the cold leg and the hot leg way, which is fathomed to 10m deep in depth.

  • PDF

Insertion Path Extraction of Catheter for Coronary Angiography (관상동맥 조영술을 위한 카테터 삽입 경로 추출)

  • Kim, Sung-Hu;Lee, Ju-Won;Kim, Joo-Ho;Lee, Han-Wook;Jung, Won-Geun;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.951-956
    • /
    • 2011
  • Coronary angiography technology is usually used for examining or treating coronary artery stenosis. Especially, when a cardiologist inserts catheter into the heart blood vessel, the catheter path detection system is needed because the cardiologist has difficulty in not damaging vessel. Recently, to reduce this difficulty, many searchers have been working for the various image processing technologies, such as vessel edge detection, optimal threshold method, etc. However the results of these searches are showing different performances depend on the contrast and quality of images. Therefore, this study for the coronary angiography suggests a novel algorithm to avoid these problems. The suggested algorithm consists of multi-sampling, interpolation, threshold method, and fault points elimination. To evaluate the performance of the proposed method, we used several angiographic images in experimentation, and we found that the proposed method is effective for detecting the catheter insertion path.