Abstract
Coronary Intervention treatment has become the core that is the test of cardiac catheterization to conduct treatment with Coronary Arteriography. Operators must be careful in Coronary Intervention treatment because the stent is inserted into the point of narrowing of blood vessel. So, the operator must correctly recognize the path of blood vessel to deal with the problems which are damages and ruptures of blood vessel, and there would be some errors of finding the path of blood vessel by bad qualify of the image. Therefore in this paper, median filtering is conducted by preprocessing to evaluate the performance of the effect of noise of the image that affects quality of the image and Fuzzy Edge Extraction Techniques is tested by using Soble Edge Extraction Techniques to compare the performance with The Fuzzy Edge Extraction Techniques. In result, the performance, removing the noise and extracting the signal of Fuzzy Edge Extraction Techniques using median filtering, demonstrates the superiority.
관상동맥 중재술은 관상동맥 조영술과 동시에 치료를 시행하는 방법으로 심도관 검사의 핵심으로 자리잡았다. 관상동맥중재술 시에는 혈관의 협착지점에 스텐트를 삽입하여야 하기 때문에 혈관의 손상이나 파열에 주의하여야 한다. 이에 시술자는 혈관의 손상이나 파열의 문제를 해결하기 위해 혈관의 경로를 정확하게 인식하여야 한다. 하지만 영상의 화질에 따른 문제들로 인하여 혈관의 경로추출에 오류를 범할 수 있다. 따라서 본 논문에서는 영상의 화질에 영향을 미치는 영상잡음에 대한 성능평가를 위하여 전처리 과정으로 미디언 필터링을 실시하였고 비교 실험을 위해 소벨 에지 추출 기법을 이용하여 퍼지 에지 추출 기법의 성능을 실험하였다. 그 결과 미디언 필터링을 적용한 퍼지 에지추출 기법의 영상이 잡음 제거와 신호의 검출 성능이 우수하게 나타났다.