• Title/Summary/Keyword: Vertical pipe

Search Result 319, Processing Time 0.028 seconds

Modeling of Liquid Entrainment and Vapor Pull-Through in Header-Feeder Pipes of CANDU

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.142-152
    • /
    • 2004
  • The liquid entrainment and vapor pull-through offtake model of RELAP5/MOD3 had been developed for SBLOCA (Small Break Loss of Coolant Accident). The RELAP5/MOD3 model for horizontal volumes accounts for the phase separation phenomena and computes the flux of mass and energy through a branch when stratified conditions occur in the horizontal pipe. In the case of CANDU reactor, this model should be used in the coolant flow of 95 feeders connected to the reactor header component under the horizontal stratification in header. The current RELAP5 model can treat the only 3 directions junctions; vertical upward, downward, and side oriented junctions, and thus improvements for the liquid entrainment and vapor pull-through model were needed for considering the exact angles. The RELAP5 off-take model was modified and generalized by considering the geometric effect of branching angles. Based on the previous experimental results, the critical height correlation was reconstructed by use of the branch line connection angle and validation analyses were also performed using SET. The new model can be applied to vertical upward, downward and angled branch, and the accuracy of the new correlations is more improved than that of RELAP5.

Borehole magnetics for the estimation of unknown foundation pile depth (시추공자력계를 이용한 기초파일 근입심도 추정)

  • Jo, Churl-Hyun;Chung, Hyun-Key;Cho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • There is an increasing need for the estimation of foundation piles whose depths are unknown. Especially in repair and reinforcement works or in safety inspection and assessment to the big structures whose foundations are piles, the accurate information about the depth of foundation piles is one of the most important factors. A borehole magnetic tool has been developed and tested to meet this object. The fundamental base is that there usually exist many re-bars inside the foundation structure such as piles, and these re-bars are ferromagnetic materials which cause strong induced magnetic field comparable to the earth magnetic field. It utilizes flux-gate type magnetometer which measures 3-components of the magnetic field. Taking vertical derivatives of vertical component of the measured magnetic field, we can expect the error limit of estimating the depth of the pile end less than 20 cm in favorable condition. The maximum measurable distance is about 3 m to the pile from the borehole. The field data show that borehole magnetics is one of the most accurate, fast, and reliable methods for this object so far, as long as there is no magnetic materials such as deep located steel pipe or power cables close to the foundation piles.

  • PDF

Estimation on End Vertical Bearing Capacity of Double Steel-Concrete Composite Pile Using Numerical Analysis (수치해석을 이용한 이중 강-콘크리트 합성말뚝 연직지지력 평가)

  • Jeongsoo, Kim;Jeongmin, Goo;Moonok, Kim;Chungryul, Jeong;Yunwook, Choo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.12
    • /
    • pp.5-15
    • /
    • 2022
  • Conventionally, because evaluation methods of the bearing capacity for double steel pipe-concrete composite pile design have not been established, the conventional vertical bearing capacity equations for steel hollow pile are used. However, there are severe differences between the predictions from these equations, and the most conservative one among vertical bearing capacity predictions are conventionally adopted as a design value. Consequently, the current prediction method for vertical bearing capacity of composite pile prediction composite pile causes design reliability and economical feasibility to be low. This paper investigated mechanical behaviors of a new composite pile, with a cross-section composed of double steel pipes filled with concrete (DSCT), vertical bearing capacities were analyzed for several DSCT pile conditions. Axisymmetric finite element models for DSCT pile and surrounding ground were created and they were used to analyze effects on behaviors of DSCT pile pile by embedding depth, stiffness of plugging material at pile tip, height of plugging material at pile tip, and rockbed material. Additionally, results from conventional design prediction equations for vertical bearing capacity at steel hollow pile tip were compared with that from numerical results, and the use of the conventional equations for steel hollow pile was examined to apply to that for DSCT pile.

Heat transfer analysis of closed-loop vertical ground heat exchangers using 3-D fluid flow and heat transfer numerical model (3차원 열유체 수치해석을 통한 현장 시공된 수직 밀폐형 지중열교환기의 열전달 거동 평가)

  • Park, Moon-Seo;Lee, Chul-Ho;Min, Sun-Hong;Kang, Shin-Hyung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.800-807
    • /
    • 2010
  • In this study, a series of numerical analyses has been performed in order to evaluate the performance of a full-scale closed-loop vertical ground heat exchanger constructed in Wonju. The circulation pipe HDPE, borehole and surrounding ground were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow water and the change of the surrounding ground temperature with depth were adopted in the FLUENT model. The thermal properties of materials estimated in laboratory were used in the numerical analyses to compare the thermal efficiency of the cement grout with that of the bentonite grout used in the construction. The results of the simulation provide a verification of the in situ thermal response test data. The numerical model with the ground thermal conductivity of 4W/mK yielded the simulation result closer to the in-situ thermal response test than with the ground thermal conductivity of 3W/mK. From the results of the numerical analyses, the effective thermal conductivities of the cement and bentonite grouts were obtained to be 3.32W/mK and 2.99 W/mK, respectively.

  • PDF

Modal Testing of Arches for Plastic Film-Covered Greenhouses (비닐하우스 아치구조의 모달실험)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2010
  • To determine the static buckling loads and evaluate the structural performance of slender steel pipe-arches such as for greenhouse structures, a series of modal tests using a fixed hammer and roving sensors was carried out, by providing no load, then a range of vertical loads, on an arch rib in several steps. More attention was given to an internal arch where vertical and horizontal auxiliary members are not placed, unlike an end arch. Modal parameters such as natural frequencies, mode shapes and damping ratios were extracted using more advanced system identification methods such as PolyMAX (Polyreference Least-Squares Complex Frequency Domain), and compared with those predicted by commercial FEA (Finite Element Analysis) software ANSYS for various conditions. A good correlation between them was achieved in an overall sense, however the reduction of natural frequencies due to the existence of preaxial loads was not apparent when the vertical load level was about up to 38% of its resistance. Some difficulties related to the field testing and parameter extraction for a very slender arch, as might arise from the influences of neighboring members, are carefully discussed.

Evaluation of Construction Operation and Design Properties of CLSM for Corrugated Pipe in Underground (파형강관을 이용한 지하매설물용 뒤채움재 설계 및 시공성 평가)

  • Lee Kwan-Ho;Park Jae-Heon
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.63-74
    • /
    • 2006
  • During the construction of circular underground pipe, the non-proper compaction along the pipe and the decrease of compaction efficiency have been the main problems to induce the failure of underground pipe or facility. The use of CLSM (controlled low strength materials) should be one of the possible applications to overcome those problems. In this research, the full-scaled field test and the numeric analysis using PENTAGON-3D FEM program were carried out for three different cases on the change of backfill materials, including the common sand, the soil from construction site, and the CLSM. From the full-scaled test in field, the use of in-situ CLSM as backfill materials reduced the vertical and lateral deformation of the pipe, as well as the deformation of the ground surface. The main reason for reducing the deformation would be the characteristics of the CLSM, especially self-leveling and self-hardening properties. The measured earth pressure at the surround of the corrugated pipe using the CLSM backfills was the smaller than the other cases, and the absolute value was almost zero. Judging from the full-scaled field test and FEM analysis, the use of CLSM as backfill materials should be one of the best choices reducing the failure of the underground pipes.

  • PDF

Identifying Risk Management Locations for Synthetic Natural Gas Plant Using Pipe Stress Analysis and Finite Element Analysis (배관응력해석 및 유한요소해석에 의한 SNG플랜트의 리스크 관리 위치 선정)

  • Erten, Deniz Taygun;Yu, Jong Min;Yoon, Kee Bong;Kim, Ji Yoon
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.1-11
    • /
    • 2017
  • While they are becoming more viable, synthetic natural gas (SNG) plants, with their high temperatures and pressures, are still heavily dependent on advancements in the state-of-the-art technologies. However, most of the current work in the literature is focused on optimizing chemical processes and process variables, with little work being done on relevant mechanical damage and maintenance engineering. In this study, a combination of pipe system stress analysis and detailed local stress analysis was implemented to prioritize the inspection locations for main pipes of SNG plant in accordance to ASME B31.3. A pipe system stress analysis was conducted for pre-selecting critical locations by considering design condition and actual operating conditions such as heat-up and cool-down. Identified critical locations were further analyzed using a finite element method to locate specific high-stress points. Resultant stress values met ASME B31.3 code standards for the gasification reactor and lower transition piece (bend Y in Fig.1); however, it is recommended that the vertical displacement of bend Y be restricted more. The results presented here provide valuable information for future risk based maintenance inspection and further safe operation considerations.

Numerical Simulation of Two-Phase Flow for Gas-Solid Particles (가스와 입자가 혼합된 2상 유동에 관한 수치해석적 연구)

  • Jung H.;Choi J. W.;Park C. G.
    • Journal of computational fluids engineering
    • /
    • v.6 no.4
    • /
    • pp.8-14
    • /
    • 2001
  • The phenomena of two-phase suspension flows appear widely in nature and industrial processes. Hence, it is of great importance to understand the mechanism of the gas-solid two-phase flows. In the present study, the numerical simulation has been approached by utilizing the Eulerian-Lagrangian methodology for describing the characteristics of the fluid and particulate phases in a vertical pipe and a 90°square-sectioned bend. The continuous phase(gas phase) is described by the Eulerian formulation and a κ-ε turbulence model is employed to find mean and turbulent properties of the gas phase. The particle properties(velocity and trajectory) are then described by a Lagrangian approach and computed using the mean velocity and turbulent fluctuating velocity of the gas phase. The predictions are compared with measurements by laser-Doppler velocimeter for the validation. As a result, the calculated results show good agreements.

  • PDF

An Experimental Study on the Safety of Temporary short pipe Scaffolding (가설 단관 비계의 안전성에 대한 실험적 연구)

  • 채원규
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.85-91
    • /
    • 1994
  • In this thesis, the fracture tests and structural analysis were performed on a series of temporary scaffolding to investigate the variation of strength and the safety of temporary scaffolding. The specimens were of height 270cm and width 50cm and their span was 120cm. The joint loading and member loading were used in the tests, respectively. In these tests, the fracture mode of temporary scaffolding, relationships between the loading and the flexural strain of the specimens were observed. According to the comparison between the test results and the structural analysis results, the effects of the vertical loads and horizontal loads on temporary scaffolding and the safety of temporary scaffolding were studied.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF