• Title/Summary/Keyword: Vertical air temperature distribution

Search Result 91, Processing Time 0.023 seconds

Performance of Refrigerated Display Cabinets in accordance with the Supply Air Jet Condition (급기제트 조건에 따른 냉동용 전시케이스의 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.80-86
    • /
    • 2011
  • Vertical open display cabinets are widely used in shopping mall, supermarkets, retail stores. Maintaining the temperature of foods in the display cabinet is vitally important to retailers to ensure optimal food quality and safety. The purpose of this study is to reduce the infiltration of air and heat loss from ambient space to display cabinet. The three-dimensional Computational Fluid Dynamics(CFD) simulation is used for the analysis of air flow patterns and temperature distribution in refrigerated display cabinets. Under several operating conditions which vary both the inner and outer jet velocities in the range from 0.3 to 1.1 m/s, simulations were carried out. This paper presents a performance of display cabinets with single jet and double jet. The energy consumption due to thermal entrainment ratio is plotted with varying Re. It was found that the double jet system is better than single jet system in terms of temperature distribution and energy saving.

Improvement of Condensation Performance in Corridor Type Apartment Door

  • Lee, Sungbok;Hwang, Hajin
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Condensation has mainly occurred in corridor type apartment door which is exposed to the outside air and is made of steel, which has high thermal conductivity. As a result, the total costs of repair have increased with the number of disputes with residents. In this study, therefore, we investigate materials and construction methods used in apartment door, perform a computer simulation to find out possible improvements, and then suggest the dew point to prevent the occurrence of condensation throughout simulation. The results indicate that the temperature that condensation does not occur is $15.4^{\circ}C$, and the optimum method of achieving this dew point is shown to be a door frame system including a large vertical slot to decrease the area of thermal conduction between the outer and inner portions of the door frame. Mock-up tests show that the surface temperature of the door frame was higher than the dew point, and the system can withstand severe cold conditions of $-20^{\circ}C$. In application test, the surface temperature of door frame with vertical slots is $5.9^{\circ}C$in average, which is higher than the existing door frame. Furthermore, in the temperature distribution of the surrounding door measured with infrared ray camera, the existing door shows the high temperature distribution indicating lack of insulation, but the improved door shows the low temperature distribution indicating higher insulation.

A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source (발열체와 부분 열림 수직벽을 갖는 사각 공간내 자연대류 특성 해석)

  • Shim, Dong-Sik;Kang, Bo-Seon;Cha, Dong-Jin;Ju, Won-Jong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.322-327
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right vertical wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The openging length as well as the divider length greatly affects the degree of inflow and outflow of air. With a small opening, the opening doesn't affect much the upward warm air flow resulting in the symmetric temperature distribution. On the other hand, with the increase of the opening length, the inward cold flow moves the upward flow to the left direction. With the increase of the divider length, temperature in the lower region of enclosure becomes higher for the small opening and lower for the large opening.

  • PDF

Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF

A Study on the Thermal Characteristics of Dry Vacuum Pump with Vertical Screws (수직형 건식 진공 스크류 펌프의 열특성에 대한 연구)

  • Chang, Moon-Suk;Park, Jae-Hyun;Kim, Soo-Tae;Kim, Il-Gon;Cho, Seong-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, analysis and experiments were carried out on temperature distributions and thermal deformations in a dry vacuum pump with vertical screws for safe operation. When a vacuum pump is working, it is necessary to get rid of the heat generated by the friction of bearings and the compression of air to prevent the vacuum pump from being damaged by interference between two screws and housing through thermal deformation. Additional cooling was proposed by using oil flow through the inner channel of the rotating axis for lower temperature control of the vacuum pump. Analysis and experimental results were compared in terms of temperature distribution and thermal deformation of the vacuum pump, and two sets of results matched reasonably well. These results for a dry vacuum pump with vertical screws can be used in similar model development and can minimize errors in design and manufacture by providing reasonably accurate prediction in advance.

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Effects of Circulation Fans on Uniformity of Meteorological Factors in Warm Air Heated Greenhouse (순환팬이 온풍난방 온실의 기상분포 균일화에 미치는 영향)

  • Yu, In-Ho;Cho, Myeong-Whan;Lee, Si-Young;Chun, Hee;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.291-296
    • /
    • 2007
  • This study was conducted to investigate the effects of horizontal air flow produced by circulation fans on horizontal and vertical profiles of meteorological factors. The three-dimensional distributions of air speed, air temperature, relative humidity and carbon dioxide $(CO_2)$ concentration were measured with and without the fans in operation. The uniformity of the spatial distribution of meteorological factors decreased as the outside air temperature decreased. In "fans off" condition, spatial variations of $4.7^{\circ}C$ in air temperature, 19% in relative humidity were detected. When the fans were operated, these variations were reduced to 2.2 and 6.3%, respectively. As the fan capacity increased, the difference in air temperature among sampling points decreased. The fan capacity of $0.0104m^3{\cdot}s^{-1}{\cdot}m^{-2}$ was enough to obtain a reasonable air flow in greenhouse. The vertical profiles of air temperature and $CO_2$ concentration were reasonably uniform regardless of measurement height and fan capacity. Further researches on the position of fans to reduce the difference in air temperature along the width and the effects of using a larger number of smaller fans are required.

A Study on the Analysis of Indoor Thermal Environment in Large Enclosure through Actual Measurement (실측을 통한 대규모 실내경기장의 온열환경 분석에 관한 연구)

  • Chae, Mun-Byoung;Yang, Jeong-Hoon;Choi, Dong-Ho;Seok, Ho-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.3-8
    • /
    • 2007
  • The purpose of this study is to grasp the characteristic of indoor thermal environment from large enclosures in connection with heating and cooling condition. This study has measured indoor thermal environment in winter and summer season. We examined indoor thermal environment of the large enclosures in this study which include vertical, horizontal temperature distribution and thermal comfort environment.

  • PDF

A Measurement and Evaluation on the Cabins' Thermal Conditions of Large Cruiser in the Winter (대형 크루저 선실의 동절기 온열환경 측정평가)

  • Hwang, Kwang-Il;Moon, Tae-Il;Park, Min-Kang;Shim, Jae-Gun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.231-232
    • /
    • 2006
  • The purpose of this study is to measure and evaluate the thermal conditions of large cruiser's cabin. As the result of this study, followings are cleared. The air volume supplied to the 2 types of cabins is quite diffenrent. Temperature differences in the Room A which is located A deck and supplied enough air volume is stable all around the cabin. But Room B which is located B deck and supplied comparatively small air volume has temperature distribution problems, like time-dependent differences, vertical differences. To serve more comfort and productivity of Room B, it is strongly recommended to do a T.A.B.(Testing, Adjusting and Balancing) for more air volume and/or to design new air flow path to make air stay longer.

  • PDF

Temperature variation in steel beams subjected to thermal loads

  • Abid, Sallal R.
    • Steel and Composite Structures
    • /
    • v.34 no.6
    • /
    • pp.819-835
    • /
    • 2020
  • The effects of atmospheric thermal loads on the response of structural elements that are exposed to open environments have been recognized by research works and design specifications. The main source of atmospheric heat is solar radiation, which dominates the variation of the temperature of air, earth surface and all exposed objects. The temperature distribution along the depth of steel members may differ with the geometry configuration, which means that the different-configuration steel members may suffer different thermally induced strains and stresses. In this research, an experimental steel beam was instrumented with many thermocouples in addition to other sensors. Surface temperatures, air temperature, solar radiation and wind speed measurements were recorded continuously for 21 summer days. Based on a finite element thermal analysis, which was verified using the experimental records, several parametric studies were directed to investigate the effect of the geometrical parameters of AISC standard steel sections on their thermal response. The results showed that the overall size of the beam, its depth and the thickness of its elements are of significant effect on vertical temperature distributions and temperature differences.