• 제목/요약/키워드: Ventilation method

검색결과 748건 처리시간 0.027초

Study on Optimization Technique for Design of the Road Tunnel Ventilation System (도로터널 환기시스템 설계 프로그램 개발)

  • 유지오;이동호;신현주
    • Journal of the Korean Society of Safety
    • /
    • 제14권4호
    • /
    • pp.60-70
    • /
    • 1999
  • In this study, the computer code for the optimal design of road tunnel ventilation system based on one-dimensional analysis of the air flow was developed. The control volume method was used to calculate the air velocities and the concentration distribution of pollutants(CO, NOx, Particulate) for various tunnel ventilation system. This code was validated by comparing the calculation results to the practical design data for the road tunnel ventilation system. The calculation results were in accord with the practical design data.

  • PDF

Characterization of Airborne Bioaerosol Concentration in Public Facilities (다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구)

  • Lee, Cheol Min;Kim, Yun Sin;Lee, Tae Hyeong;Park, Won Seok;Hong, Seung Cheol
    • Journal of Environmental Science International
    • /
    • 제13권3호
    • /
    • pp.215-222
    • /
    • 2004
  • This study was conducted to evaluate the characterization of airborne bioaerosol in public facilities in Seoul. A total of 17 public facilities were investigated from December, 2002 to February, 2003. As results of the survey, the mean concentrations of bacteria and fungi in indoor air of public facilities were $378.08\pm296.33$ CFU/㎥ by RCS and $106.38\pm171.63$ CFU/㎥ and $347.46\pm335.32$ CFU/㎥ and $95.23\pm62.61$ CFU/㎥, by Six-stage cascade air sampler respectively. The mean concentrations of bacteria in indoor air (by ventilation method) were $517.14\pm343.93$ CFU/㎥ of natural ventilation and $215,83\pm100.71$ CFU/㎥ of mechanical ventilation. The mean concentrations of fungi in indoor air (by ventilation method) were $83.14\pm79.16$ CFU/㎥ of natural ventilation and $133.50\pm248.07$ CFU/㎥ of mechanical ventilation. The mean concentrations of bacteria in indoor air were 449.44 CFU/㎥ for the ground and $217.50\pm103.68$ CFU/㎥ for the underground. The mean concentrations of fungi in indoor air were $63.89\pm77.66$ CFU/㎥ for the ground and $202.00\pm290.08$ CFU/㎥ for the underground.

The Study on the Renovation Method of Apartment House Ventilation System for Reducing Indoor Air Contamination (실내오염 저감을 위한 공동주택 환기시스템의 개선방안에 대한 연구)

  • Hwang, Tae-Chul;Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제20권6호
    • /
    • pp.409-415
    • /
    • 2008
  • Recently, Indoor air quality (IAQ) is one of the most important problem in our daily life of modern societies. Mechanical ventilation system is being recommended as an effective method to improve IAQ in apartment houses. And then, in Korea, building industry should install ventilation system in apartment house by the building construction code. In this study, to improve IAQ caused by microbial and chemical contaminant such as bacteria and TVOC, three types of mechanical ventilation system of apartment house including HRV were simulated by multizone modeling. Simulation results suggest an appropriate and economical renovation method of apartment house ventilation system for reducing indoor air contamination.

Clinical Application of Nasal Intermittent Positive Pressure Ventilation with Bi-level Positive Airway Pressure(BiPAP) (기도 이중 양압(BiPAP)을 이용한 비강 간헐 양압환기의 임상적 적용)

  • Cho, Jae-Youn;Lee, Sang-Youb;Lee, Sang-Hwa;Park, Sang-Myun;Suh, Jung-Kyung;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권5호
    • /
    • pp.723-730
    • /
    • 1995
  • Background: Noninvasive ventilation has been used extensively for the treatment of patients with neuromuscular weakness or restrictive chest wall disorders complicated by hypoventilatory respiratory failure. Recently, noninvasive positive pressure ventilation has been used in patients with alveolar hypoventilation, chronic obstructive pulmonary disease(COPD), and adult respiratory distress syndrome. Sanders and Kern reported treatment of obstructive sleep apnea with a modification of the standard nasal CPAP device to deliver seperate inspiratory positive airway pressure(IPAP) and expiratory positive airway pressure(EPAP). Bi-level positive airway pressure(BiPAP) unlike nasal CPAP, the unit delivers a different pressure during inspiration from that during expiration. The device is similar to the positive pressure ventilator or pressure support ventilation. Method and purpose: Bi-level positive airway pressure(BiPAP) system(Respironics, USA) was applied to seven patients with acute respiratory failure and three patients on conventional mechanical ventilation. Results: 1) Two of three patients after extubation were successfully achieved weaning from conventional mechanical ventilation by the use of BiPAP ventilation with nasal mask. Five of seven patients with acute respiratory failure successfully recovered without use of conventional mechanical ventilation. 2) $PaO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients significantly improved more than baseline values(p<0.01). $PaCO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients did not change significantly more than baseline values. Conclusion: Nasal mask BiPAP ventilation can be one of the possible alternatives of conventional mechanical ventilation in acute respiratory failure and supportive method for weaning from mechanical ventilation.

  • PDF

Simulation and Analysis of Local Ventilation characteristic of Road Tunnel with Ventilation System (환기시스템 적용 도로터널의 국소환기 특성 시뮬레이션 및 해석)

  • 박기림;오명도;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제13권5호
    • /
    • pp.321-332
    • /
    • 2001
  • In this study, a design program for ventilation requirements of a longitudinal raod tunnel were developed and investigated. The control volume method was applied to calculate the local air velocity and the local concentration distribution of pollutants, CO, $NO_x$, soot along the tunnel for various tunnel ventilation system. This program was validated by comparing with the practical design data for the road tunnel ventilation system. The calculation results were in good agreement with the practical design data.

  • PDF

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method (추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구)

  • Kim, Young-su;Roh, Jang-hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • Natural ventilation is employed in limestone mines that have been currently operated in Korea, and there has been a growing issue of a significantly weak airflow caused by the large-scale excavation. Thus, the air quality in the working area is considerably poor. In order to improve this circumstance, it is mainly required to examine ventilation performance. In this study, the examination of ventilation efficiency was conducted by using tracer gas method. The result of this work indicated detailedly the ventilation problems in research mine, in that extremely low air velocity, recirculation, and air change rate were evaluated quantitatively using tracer gas. Therefore the ventilation performance evaluation using tracer gas can be opted as a precise method to improve the working area in mines.

A Study on How to Evaluate Appropriate Ventilation Rate of Indoor Facility Handling Hazardous Substances by Their Flammable and Explosive Properties (유해화학물질을 취급하는 실내시설에서의 인화폭발성에 따른 적정 환기량 산정에 대한 연구)

  • Mansu Park;Cheong-Min Seo;Hyo-Soub Yoon;Kyoshik Park
    • Journal of the Society of Disaster Information
    • /
    • 제20권2호
    • /
    • pp.293-301
    • /
    • 2024
  • Purpose: Ministry of Environment statistics reveals more than 132 fire·explosion accidents in South Korea between 2014 and 2023. Among them, fire and/or explosion accidents are very impactive in their scale and consequence. This study aims to suggest a new method of reasonable way to calculate the ventilation rate of indoor facility handling hazardous chemicals based on their inflammability. Method: A new method to calculate the ventilation rate is based on the physicochemical properties of the chemicals handled, which is more reasonable compared with the current regulation based only on the floor area of the facility. Result: Considering the physicochemical properties, 178 chemicals based on their inflammability were studied and 168(94%) met the criteria for the current regulation. Some materials have been shown to require too much or too little ventilation rate. Conclusion: Through this study, a reasonable method of calculating the required ventilation rate was proposed. This should be applied to ensure the safety of workers to deal chemicals.

Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method (T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석)

  • 문종선;강석윤;이승철;유호선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권3호
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.