• Title/Summary/Keyword: Ventilation condition

Search Result 445, Processing Time 0.03 seconds

Radon distribution in geochemical environment and controlling factors in Radon concentration(Case study) (지구화학환경에서의 라돈농도분포와 라돈농도의 지배요인(사례연구))

  • 전효택
    • The Journal of Engineering Geology
    • /
    • v.10 no.2
    • /
    • pp.189-214
    • /
    • 2000
  • Three study areas of Kwanak campus(Seoul National University), Gapyung and Boeun were selected and classified according to bedrock types in order to investigate soil-gas radon concentrations. Several soil-gas samples showed relatively high radon concentrations in the residual soils which derived from granite bedrock. It also showed that water content of soil and the degree of radioactivity disequilibrium was a secondary factor governing radon emanation and distribution of radon radioactivity. The results of radon concentrations and working levels for forty rooms in Kwanak campus, Seoul National University, showed that indoor basement rooms under poor ventilation condition can be classified as high radon risk zone having more than EPA guideline(4 pCi/L). Some results of section analysis which was surveyed in the fault zone of Kyungju and Gapyung area confirmed the existence of fault-associated radon anomalies with a meaning of radon risk zone.

  • PDF

A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period (박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구)

  • Park, Chang-Young;Lee, Keon-Ho;Yoon, Yong-Sang;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

DECREASE OF OXYGEN SATURATION DURING DENTAL TREATMENT UNDER GENERAL ANESTHESIA OF DOWN SYNDROME PATIENT WITH CONGENITAL HEART DISEASE -A CASE REPORT- (선천성 심장질환을 가진 다운증후군환자에서 치과치료를 위한 전신마취 시 산소포화도 하강 -증례보고-)

  • Seo, Kwang-Suk;Chang, Ju-Hea;Shin, Teo-Jeon;Kim, Hyun-Jeong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • A 26-year-old female patient with Down syndrome visited to recieve dental treatment under gnenral anesthesia 6 years ago. The patient had difficulties in oral examination, radiograph taking and laboratory test. The patient had congenital heart disease and medical consultation based on the echocardiography was provided by a cardiologist indicating that the patient could tolearte general anesthesia during dental treatment. And two times of general anesthesia were administered during a dental treament with the interval of 3 years and no postoperpative complicaton was reported. At the third dental operation, the patient had a relatively good condition and her prescreening test revealed no abnormalities. Without further consultation with a cardiologist, general anesthesia was administered to the patient. Anaesthesia was based on thiopental and ventilation of desflurane and $N_2O$ in oxygen via an endotracheal tube with an appropriate monitoring. During the maintenance of anesthesia, the blood pressure of the patient started to drop and the oxygen saturation also began to decrease. Consequently, the proceding operation was discontinued and also inhalation anesthesia was ceased. As the patient was recovered from anesthesia, her systemic conditions were alleviated. After the complete recovery of the patient, she visited the cardiologist, and the cardiologic test revealed her severe right ventricular dilatation. In the anesthesia of patients with congenital heart disease, information on their systemic conditions needs to be undated from the medical consultation, which assures the safety of treatment.

  • PDF

Four Cases of Kartagener's Syndrome (Kartagener 증후군 4예)

  • Lee, Yong-Chul;Song, Hang-Yong;Lim, Suk-Tae;Kim, Hyung-Chung;Lee, Heung-Bum;Lee, Young-Seung;Rhee, Yang-Keun;Chung, Jae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.663-669
    • /
    • 1994
  • Kartagener's sydrome is an autosomaly inherited recessive condition characterized by situs inversus, bronchiectasis, and chronic sinusitis. And recently it was recognized as a subclass of dyskinetic cilia syndrome which caused by a defect in mucociliary transport owing to immotile or dyskinetic beating of cilia. Electron microsopy of cilia from sperm tails, nasal and bronchial epithelium of patients reveals the partial or complete absence of dynein arms. Our four patients were diagnosed as a Kartagener's syndrome by classic triad. We carried out electron microscopy of cilia of the nasal mucosa. And many other tests were done. One patient had squamous cell carcinoma of the lung, and another one patient revealed features of adult respiratory distress syndrome at admission. All patients improved with conservative therapy such as physiotherapy, bronchodilater, antibiotics except one patient who mechanical ventilation was required. A brief review of literature was made.

  • PDF

Successful High Flow Nasal Oxygen Therapy for Excessive Dynamic Airway Collapse: A Case Report

  • Park, Jisoo;Lee, Yeon Joo;Kim, Se Joong;Park, Jong Sun;Yoon, Ho Il;Lee, Jae Ho;Lee, Choon-Taek;Cho, Young-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.4
    • /
    • pp.455-458
    • /
    • 2015
  • Excessive dynamic airway collapse (EDAC) is a disease entity of excessive reduction of the central airway diameter during exhalation, without cartilage collapse. An 80-year-old female presented with generalized edema and dyspnea at our hospital. The patient was in a state of acute decompensated heart failure due to pneumonia with respiratory failure. We accordingly managed the patient with renal replacement therapy, mechanical ventilation and antibiotics. Bronchoscopy confirmed the diagnosis of EDAC. We scheduled extubation after the improvement of pneumonia and heart condition. However, extubation failure occurred due to hypercapnic respiratory failure with poor expectoration. Her EDAC was improved in response to high flow nasal oxygen therapy (HFNOT). Subsequently, the patient was stabilized and transferred to the general ward. HFNOT, which generates physiologic positive end expiratory pressure (PEEP) effects, could be an alternative and effective management of EDAC. Further research and clinical trials are needed to demonstrate the therapeutic effect of HFNOT on EDAC.

A study on the perception about the Situation of Facilities and Utilities of Foodservice in Chonbuk Area (전북지역 학교급식의 시설.설비에 대한 영양사의 인지도 조사)

  • Choi, Hyu-Yeun;Yang, Hyang-Sook;Rho, Jeong-Ok
    • Korean Journal of Human Ecology
    • /
    • v.10 no.1
    • /
    • pp.59-70
    • /
    • 2007
  • This study was conducted to investigate the perception about situation about school foodservice facilities and utilities in Chonbuk area. Self administered questionnaires were collected from 222 dietitians. Statistical data analysis was completed using a SPSS v. 10.0 program. The results are summarized as follows: Among 222 school foodservice systems, 68.5% of schools prepared the meal with conventional way and 31.5% of with commissary way. As the results of condition of school foodservice facilities, there was significantly differences between conventional and commissary foodservice systems; wall and ceilings(p<0.05), lighting(p<0.05), kitchen ventilation(p<0.05), preparation facilities(p<0.01), washstands(p<0.05), dressing rooms for employees(p<0.001), rest, and showers(p<0.01). On the basis those result it was assumed that the status of facilities of conventional foodservice systems better than commissary ones. About 66% of conventional foodservice systems and 34.5% of commissary ones have conducted own dining rooms. As to situation of dining rooms, conventional foodservice systems had better facilities than commissary ones. Therefore, governmental regulation agencies have to review and approval of plans prior to new construction or extensive remodeling of school foodservice facilities. In addition, content analysis was conducted regarding to dietitian's opinions on foodservice facilities and utilities.

  • PDF

On the Reliability of the Computational Fire Model Based on the Yield Rate Concept of Combustion Gases (생성율 개념에 기초한 화재모델의 신뢰성에 대한 연구)

  • Kim, Sung-Chan;Ko, Gwon-Hyun;Lee, Seong-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.130-136
    • /
    • 2009
  • The present study has been performed to evaluate the reliability of the fire field model (FDS version 5.2) with yield rate concept of combustion products. The CO and smoke density predicted by FDS model was directly compared with measurement in a reduced scale ISO-9705 room. The GER (global equivalence ratio) concept was used to characterize the CO and smoke density with ventilation condition in the fire compartment. The FDS model tends to under-predict CO concentration and smoke density than those of measurement for the under-ventilated conditions. Also, the discrepancy between predicted and measured result increases as GER increases. In order to improve the reliability of the fire model for performance evaluation of fire safety, the fire model is necessary to be validated in various fire cases as well as develop detailed physical model.

Evaluation of the Thermal Properties of Disposable Coveralls for Railroad Carriage Maintenance Workers (철도 차량 정비 작업자를 위한 일회용 부직포 작업복의 온열적 성능 평가)

  • 최정화;이주영;김소영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.8
    • /
    • pp.1175-1185
    • /
    • 2004
  • This study evaluated thermo-physiological and subjective properties of improved disposable coveralls for railroad carriage maintenance through climatic chamber trials and a filed study. Subjects wore five kinds of disposable coveralls (Type A: a disposable coverall on the market, Type B: a coverall with an improved hood and size-adjustable design, Type C: a coverall with a portable hood, Type D: a coverall with small holes for ventilation, Type E: a sleeveless coverall, Type F: a separated type of coverall with half sleeves) The air temperature in the climatic chamber was set in 9$^{\circ}C$ and 30$^{\circ}C$ For each condition, subjects simulated the railroad work for 120min. and rectal temperature, skin temperatures, clothing microclimate and subjective sensations were measured. The results of chamber trials showed rectal temperature and clothing microclimate did not display significant differences by clothing type. In 30$^{\circ}C$ air temperature, mean skin temperature was higher in Type E and Type F than in Type A(p<0.05) but between the improved coveralls(B-F), we could not find any significant difference. In the case of thermal comfort, the most preferred types were Type B and Type C in 9$^{\circ}C$ and Type F in 30$^{\circ}C$. All subjects felt more comfortable in the improved coveralls than in coveralls of the market (Type A). In field study, workers preferred Type B, Type C and Type F to Type A but the most favorite type differed by the specific type of work. Especially, workers were dissatisfied that Type D tore easily due to lots of small holes around the armpits and Type I did not protect workers' shoulder and arms from oil contamination. According to the climatic chamber trials and field study, the most effective coveralls were Type B and Type C for winter and Type F for summer.

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

3D Terrain Analysis and Suitability Analysis Using KOMPSAT 2 Satellite Images (아리랑2호 영상을 이용한 3차원지형 분석 및 적지분석)

  • Han, seung-hee;Lee, jin-duk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.436-440
    • /
    • 2008
  • Complete consideration on condition and surrounding environment shall be performed to select proper location for complex planning or establishment of facility with special purpose. Especially, in case of living space for human, lighting, ventilation, efficiency in land use, etc. are important elements. Diverse 3D analysis through 3D topography modeling and virtual simulation is necessary for this. Now, it can be processed with relatively inexpensive cost since high resolution satellite image essential in topography modeling is provided with domestic technology through Arirang No. 2 satellite (KOMPSAT2). In this study, several candidate sites is selected for complex planning with special purpose and analysis on proper location was performed using the 3D topography modeling and land information. For this, land analysis, land price calculation, slope analysis and aspect analysis have been carried out. As a result of arranging the evaluation index for each candidate site and attempting the quantitative evaluation, proper location could be selected efficiently and reasonably.

  • PDF