• Title/Summary/Keyword: Ventilation Type

Search Result 472, Processing Time 0.024 seconds

Estimation of Surplus Solar Energy in Greenhouse (I) - Case Study Based on 1-2W Type - (온실내 잉여 태양에너지 산정 (I) - 1-2W형을 중심으로 -)

  • Suh, Won-Myung;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • This research performed to analyze surplus solar energy, which is generated from a greenhouse during daytime, and to make the basic materials for designing thermal energy storage system for surplus solar energy. For this goal, it analyzed the surplus solar energy coming from two types of greenhouse. The results of this research are as per the below: In the case of 1-2W-type greenhouse, this research gave the same temperature and ventilation condition regardless of regions, but it was judged that the quantity of surplus solar energy could be greatly changed, depending on the energy consumed for the photosynthesis and evapotranspiration of crops in the greenhouse, on the heating temperature during daytime and night, on the existence/non-existence of a curtain and its warming effect, and on the ventilation temperature suitable for the overcoming of high temperature troubles or for the optimum cultivation temperature. In the case of a single-span greenhouse, there was a big difference in energy incoming and outgoing by month, but throughout seasons, 85.0 % of the total energy put into the greenhouse was solar energy and the energy input by heating was just 15.0 % of the total. 26.4 % of the total energy input for the greenhouse was used for photosynthesis and evapotranspiration of crops, and 44.2 % of the remaining 73.6 % went out in the form of radiant heat through the surface of the greenhouse. That is, 25.2 % of the total energy loss was just the surplus solar energy. 67.6 % of the total heating energy was concentrically used for 3 months from December to February next year, but the surplus solar energy during the same period was just 19.4 % of the total annual quantity so it was found that the given condition was more restrictive in directly converting the surplus heat into greenhouse heating. Under the disadvantageous circumstance of 3 months from December to February next year, it was possible to supplement 28 % (December) $\sim$ 85 % (February) of heating energy with surplus solar energy.

A Comparative Study on Small-Sized Apartment Plan Composition in Seoul and Shanghai (서울과 상해 소형아파트의 평면구성 비교 연구)

  • Park, Su kyeong
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.3
    • /
    • pp.173-180
    • /
    • 2014
  • Dwelling connotes characteristics like social and cultural and technical climatic conditions, lifestyles and demands of regions, and especially, apartment, as one of dwelling types, shows various aspects of modern society. With the economic development centering on large cities, apartments have been established as universal housing forms in Seoul and Shanghai. The deepening of economic development in cities has increased small households consisting of one or two persons by affecting the population and household structure, and they've become information consumer groups. This has also influenced the size of apartment and increased the demand for small-sized housing. If the floor area is small, it is possible to use space widely according to the plan composition, so there is a need for floor planning to understand natural environment, physical environment and residents.This study compared and analyzed plan compositions of small-sized apartments which have been parceled out for the recent three years in Seoul and Shanghai. This study aims to understand housing cultures and users in the two countries depending on natural environments, living habits and spatial functions by analyzing common points and differences of public spaces like living room, dining room and kitchen, and private spaces like bedroom which have absolute effects on room arrangement and traffic line. The study results are as follows. From the perspective of natural environments, in Seoul, two-sided open cross-ventilation structure where is favorable to lighting and ventilation, occupied the biggest proportion of public space, while in Shanghai, most public spaces had lighting and ventilation structures through windows in each room. In Seoul, 3R type occupied the largest proportion of private space(87.7%), and privacy was maintained and space scale was adjusted using spaces with diverse functions such as bathroom in the couple bedroom, dress room and powder room and variable walls. But 2R type occupied the largest proportion of private space(60.2%) in Shanghai, and they emphasized private space and privacy of each room depending on major living habits. In conclusion, this study for comparing and analyzing common points and differences of small-sized apartment plan compositions in Seoul and Shanghai will provide proper guidelines for small-sized apartments to be built in Seoul and Shanghai in the future, if strong points and weak points of plan compositions in the two countries will be additionally analyzed and remedied.

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner Coupled with Ventilation System

  • Kwon, Yong-Il;Han, Hwa-Taik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.101-107
    • /
    • 2007
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in two different ways in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

DESIGN AND OPTIMIZATION STUDY ON THE F-15K IGLOO DIFFUSER (F-15K 엄체호 분사구 최적 설계에 관한 연구)

  • Yoon, Y.H.;Kim, S.C.;Cho, H.K.;Lee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.66-69
    • /
    • 2009
  • New design configurations were developed based on the closed ventilation type igloo nozzle in contrast to the conventional open distribution type. To validate the enhanced performance, the prediction of the exhaust flow patterns of the igloo diffuser was carried out by both experimental and computational simulations. CFD provided detailed parametric studies that significantly reduced the amount of experimentation necessary to alter the design of existing the F-15K igloo exhaust diffuser.

  • PDF

A Study on the Characteristics of the Apartment unit Plans According to the Outdoor Adjacency Methods (I) (외기인접방식에 따른 아파트 단위평면 특징에 관한 연구(I))

  • Park Mong-Sub
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.19-25
    • /
    • 2005
  • This paper call attention to the characteristics of apartment unit plans as to the outdoor adjacency methods. My arguments will attempt to investigate spatial composition and each room sizes of the unit plans. So far, very little has been done in this direction. I will limits myself to study 573 plans which have been designed from 1996 till 2003. What emerges from this analysis is that these samples divided 3 types derived from the outdoor adjacency methods. Type 1 limits itself to 39 square meters unit plans. Type 2 was distributed from 49 square meters to 200 square meters with the exception of 100-110 square meters. And, type 3 ranges from 59 to 160 square meters. Therefore, it could be profitable each room's environmental condition (daylight, ventilation and etc) and diverse apartment building types to design in extent 49-160 square meters.

Estimation of the Formaldehyde Concentration of Subterranean Shopping Centers according to their Spatial Configuration and Renovation (지하도상가의 리모델링 및 공간 특성에 따른 포름알데히드 농도 분석)

  • Sim, Kyung-Sub;Kim, Hyunsoo;Yu, Seulgi;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.182-187
    • /
    • 2014
  • Underground shopping center has become a important commercial facility due to their good accessibility to the public transport. However, underground shopping center has high risk of air contaminants emission like formaldehyde and lowered indoor air quality. In this study, formaldehyde concentration of the underground shopping center was estimated according to the renovation and characteristics of space. It was found that newly renovated underground shopping center has low formaldehyde concentration. In case of closed entrance type, the formaldehyde concentration was 320 % higher than open type. Formaldehyde concentration was varied by product type and especially, high formaldehyde concentration was measured near the stores selling nail polish and cosmetics. It is important to apply appropriate ventilation system according to characteristics of space.

  • PDF

Earthquake performance of FRP retrofitting of short columns around band-type windows

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.53 no.1
    • /
    • pp.1-16
    • /
    • 2015
  • Due to design codes and regulations and the variety of building plans in Turkey, it is very often seen that band-type windows are left for ventilation and lightening of the basements of buildings which are used for various purposes such as workplaces and storage. Therefore when the necessary support measures cannot be given, short columns are subjected to very high shear forces and so damage occurs. One of the precautions to avoid the damage of short column mechanisms in buildings where band-type windows are in the basement is to strengthen the short columns with fiber reinforced polymer (FRP). In this study, the effect of the FRP retrofitting process of the short columns around band-windowed structures, which are found especially in basement areas, is analyzed in accordance with Turkish Seismic Code 2007 (TSC 2007). Three different models which are bare frame, frame with short columns and retrofitted short columns with FRP, are created and analyzed according to TSC 2007 performance analysis methods to understand the effects of band windows in basements and the effect of FRP retrofitting.

A case of combined lung cancer squamo-adeno-undifferentiated carcinoma (혼합형 원발성 폐암 1례 보고)

  • 김송명
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.368-374
    • /
    • 1983
  • Combined type of primary lung cancer is a very rare form in clinical experience, which is 3 histologically different variants of bronchogenic carcinoma. These type had a well differentiated squamous carcinoma forming keratin pearls, well differentiated adenocarcinoma and pleomorphic undifferentiated cell carcinoma, usually small cell carcinoma. The patient, a male, 49-Y-0, was complaint coughing, mild dyspnea, blood tinged sputum and chest pain. Under diagnosis of lung cancer preoperatively, the right total pneumonectomy was performed with very difficulty such as arrhythmia, ventilation impairment during post operation course. The histology of specimen was disclose as 3 different histological type, combined lung cancer as squamoadenoundifferentiated carcinoma. The mediastinal nodes were freed from metastasis but the parietal pleural metastatic loci was found. The radio & chemotherapy were performed post-operatively. The patient had been experienced empyema at post-pneumonectomy space and then open drainage procedure and thoracoplasty had been added for treatment course. The patient is alive recently.

  • PDF

Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System (실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교)

  • Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

Accelerated and Outdoor Exposure Tests of Aluminum Coated Steel Sheets

  • Kim, Jongmin;Lee, Jaemin;Lim, Sangkyu;Jung, Choonho
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.199-204
    • /
    • 2011
  • Hot dip metallic coated steels like as galvanized (GI), zinc-aluminium (GL) and aluminium coated steels are mostly used where corrosion resistance is needed. There are two kinds (type 1 and type 2) of aluminium coated steel being commercially used among them. Type 1 aluminium coated steel is coated with an Al-5~11 wt%Si alloy and Type 2 aluminium coated steel consists of commercially pure aluminium. Type 1 Al coated steel is generally used in automotive components and electrical appliances while type 2 aluminium coated steel is mainly used in construction applications such as building cladding panels, air conditioning and ventilation system. In this study, Type 1 aluminium coated steels have tested by accelerated conditions (salt spray or corrosive gas) and outdoor exposure condition in order to understand their corrosion behaviour. Due to the distinct corrosion mechanism of Al which exposes to the severe chloric condition, Salt Spray Test cannot predict the ordinary atmospheric corrosion of Al based coated materials. In addition, the test results and their corrosion feature of Al coated steel sheets will be discussed comparing with other metallic coated steel sheets of GI and GL.