• Title/Summary/Keyword: Ventilation Standard

Search Result 300, Processing Time 0.037 seconds

Studies on the Paper Interior Materials of Tradition(Part 1) - Physical and Strength Properties of Changhoji - (전통 지류 인테리어 소재에 관한 연구(제 1보) - 창호지의 물리, 강도적 특성 -)

  • Yoon, Seung-Lak
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.3
    • /
    • pp.80-87
    • /
    • 2011
  • This research was performed to investigate the physical and mechanical properties of Chanhoji manufactured with the traditional method. This research would provide a basic information for its application in the manufacture of Korean-style house. A piece of Changhoji was manufactured to have a weight of 3.75 g. The weight was increased with the basic weight and no increase was not found on its density. The strength properties of Changhoji are superior to a copying paper, and the quality showed the first grade in Korean Standard (KS M 7301). The air resistance varied with the thickness from 2 to 19 seconds, but it showed better performance than a copying paper having 38 seconds. This research would be used for the practical use in understanding the ventilation and lightening properties of windows and doors in Korean-style house.

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

A Study on Indoor Environmental Factors in Elementary School Classroom for Eco-School Planning (에코스쿨 계획을 위한 초등학교 실내 환경계획 요소 조사)

  • Kim, Chang-Sung;Kang, Seung-Ku
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.6
    • /
    • pp.4-11
    • /
    • 2008
  • Global environment is getting deteriorated at an alarming rate. Eco-school could be one of the effective solutions to protect our environment and a good sample of architecture to economize in total energies, resources and greenhouse gases. In case of our country, the study of eco-school planning is not sufficient compared with other countries, so this paper would be a good study on the indoor environment of the classroom by surveying their opinions and ideas from the group of users in elementary school. The result of this study shows that the proper installation of building equipment and nature ventilation system is necessary to provide delightful environment for the students and to save the energy. To ensure that we have adequate saving and protection, it is necessary to change the existing appraisal standard.

A Investigation on the Present state of Code of Design and Specification for Building Mechanical Engineering (표준시방서 및 설비설계기준의 개정현황에 관한 고찰)

  • Kwon, Yong-Il;Park, Jung-Won;Park, Jong-Il;Kim, Doo-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.566-571
    • /
    • 2006
  • The purpose of this code is to relate the various controllable factors to the comfort and well-being of the people using the building, so that the requirements of the system may be specified to the designers and the constructor. This study deals with the work involved in design and installation of residential mechanical ventilation. The recommendations made in this code recognize the need to optimize the use of energy, reduce hazards and minimize effects detrimental to the environment. This code was prepared by a committee convened by SAREK. The code provides broad guidance only on certain topics. The titles of standard and code referred to in this code are listed on the reference.

  • PDF

Measurement and Analysis of Odors Generated in Traditional Markets

  • KIM, Su-Hye;CHO, Dong-Myung;KWON, Lee-Seung;JUNG, Min-Jae
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.4
    • /
    • pp.35-41
    • /
    • 2021
  • Purpose: The purpose of this study is to identify the causes of odors generated in traditional markets and to suggest appropriate application technologies to solve them. Research design, data and methodology: In order to achieve the purpose of this study, complex malodors, TVOC, and hydrogen sulfide were measured three times at each point in Wonju-city, Gangwon-do using direct-reading odor measuring equipment in Joong-ang Traditional Market's Korean beef Alley, Sundae Alley, and Joong-ang Citizens Traditional Market. Therefore, the average value was compared with the emission standard and analyzed. Results: As a result of the study, complex malodors exceeded the emission standards at all points, and hydrogen sulfide exceeded the emission standards at all except for one point. Conclusions: The odor generated in the traditional market has various causes and low concentration, so it is necessary to reduce the odor by using an appropriate technology.

Studies of VETH Plot for Standard Design of Evaporative Cooling at Summer Glasshouse (하절기 유리온실의 증발냉각 설계기준을 위한 VETH 선도 연구)

  • Woo, Y.H.;Ahn, Y.K.;Kim, D.E.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.20 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Judicious control of high temperature is the most important task for the successful intensive-cultivation of vegetables in glasshouses during the hot summer. Estimation of cooling load and wise selection of suitable equipments and facilities based upon the environmental conditions are essential for the efficient temperature control. A series of experiments were carried out to investigate VETH(ventilation, evapotranspiration, temperature and humidity) plot was prepared for the possible practical application in designing some evaporated cooling methods for the following 9 locations; Seoul, Seosan, Taejeon, Pusan, Cheju, Kwangju, Taegu, Chonju, and Chinju.

Cardiac function associated with home ventilator care in Duchenne muscular dystrophy

  • Lee, Sangheun;Lee, Heeyoung;Eun, Lucy Youngmin;Gang, Seung Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.2
    • /
    • pp.59-63
    • /
    • 2018
  • Purpose: Cardiomyopathy is becoming the leading cause of death in patients with Duchenne muscular dystrophy because mechanically assisted lung ventilation and assisted coughing have helped resolve respiratory complications. To clarify cardiopulmonary function, we compared cardiac function between the home ventilator-assisted and non-ventilator-assisted groups. Methods: We retrospectively reviewed patients with Duchenne muscular dystrophy from January 2010 to March 2016 at Gangnam Severance Hospital. Demographic characteristics, pulmonary function, and echocardiography data were investigated. Results: Fifty-four patients with Duchenne muscular dystrophy were divided into 2 groups: home ventilator-assisted and non-ventilator-assisted. The patients in the home ventilator group were older ($16.25{\pm}1.85years$) than those in the nonventilator group ($14.73{\pm}1.36years$) (P=0.001). Height, weight, and body surface area did not differ significantly between groups. The home ventilator group had a lower seated functional vital capacity ($1,038{\pm}620.41mL$) than the nonventilator group ($1,455{\pm}603.2mL$). Mean left ventricular ejection fraction and fractional shortening were greater in the home ventilator group, but the data did not show any statistical difference. The early ventricular filling velocity/late ventricular filling velocity ratio ($1.7{\pm}0.44$) was lower in the home ventilator group than in the nonventilator group ($2.02{\pm}0.62$. The mitral valve annular systolic velocity was higher in the home ventilator group (estimated ${\beta}$, 1.06; standard error, 0.48). Patients with Duchenne muscular dystrophy on a ventilator may have better systolic and diastolic cardiac functions. Conclusion: Noninvasive ventilator assistance can help preserve cardiac function. Therefore, early utilization of noninvasive ventilation or oxygen may positively influence cardiac function in patients with Duchenne muscular dystrophy.

Design Standard of Activated Carbon Vessel for the Intermittent Emission Sources of Volatile Organic Compounds (휘발성 유기화합물의 간헐적 배출원에 대한 활성탄 흡착 시스템 설계기준)

  • Lee, Si-Hyun;Lim, Jeong-Whan;Rhim, Young-Jun;Kim, Sang-Do;Woo, Kwang-Je;Son, Mi-Sook;Park, Hee-Jae;Seo, Man-Cheol;Ryu, Seung-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.250-260
    • /
    • 2007
  • It was investigated that the emission characteristics of volatile organic compounds (VOCs) from small and medium companies located on industrial complexes in Metropolitan area. The emission characteristics are intermittent sources in which VOCs emissions are highly depends on the working condition. Optimized ventilation system to improve air quality in working area for the three typical companies were installed. Adsorption characteristics of major VOCs such as MEK, IPA, and toluene emitted front the companies were investigated for design of the activated carbon vessel as a VOCs control facility in each company. Concentration of total hydrocarbon and gas amounts needed to ventilation were also used as a design parameter. Mixed adsorbent to improve adsorption characteristics of problematic solvents like IPA and the design guideline of the activated carbon vessel have been suggested.

Research trends on prevention of heat stroke using clothing: Focusing on practical research in Japan (의복을 활용한 열중증 예방 대책에 관한 연구 동향 조사: 일본의 실용 지향적 연구를 중심으로)

  • Son, Su-Young
    • Human Ecology Research
    • /
    • v.56 no.5
    • /
    • pp.473-491
    • /
    • 2018
  • This study identifies Japanese study content on heat stroke prevention measures using clothes, provides basic data for quantitative wearing assessment studies, presents a developmental direction for those, and helps invigorate further research. Studies were collected concerning clothing-based heat stroke measures in order to analyze the following factors: current status of heat stroke by industry and working environment, heat stroke and body cooling method, clothing microclimate and air circulation in a hot environment, hot environments and wearable sensors, and heat stress reduction and skin exposure. The current WBGT standard does not consider the diversity of wearing clothes according to the working environment. Therefore, it is preferable to add a correction value in consideration of design, materials, and ventilation to prevent heat strokes. For the heat stroke and body cooling method, wearing water-perfused clothing is effective to reduce heat stress and maintain exercise ability. Changing the material and design of clothing or wearing air-conditioned clothing can improve ventilation and the clothing microclimate. However, further evaluation is needed on the effectiveness of air-conditioned clothing as a heat stroke prevention product. The measurement method using a wearable sensor can provide real-time data on the body response due to working in a hot environment. Therefore, it is an effective alarm for heat stroke. Skin exposure area and heat dissipation efficiency should be considered to prevent heat stroke. Reducing the covering area by exposing the head, neck, and limbs, and wearing breathable material can prevent heat stroke from increased body temperature.

A Study on Improvenment of Livingroom Smoke-control System using the FDS (화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구)

  • Kim, Mi-Seon;Baek, Eun-Seon
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.26-34
    • /
    • 2017
  • The purpose of this study is to identify and improve the performance of the adjacent room ventilation system in living room ventilation facilities, and compare and analyze the smoke control regulations of the NFPA code and the national fire safety standard (NFSC). The analysis method was fire dynamics simulation (FDS) and was used to analyze the, variations of the air supply amount, width of the boundary, change in indoor combustion and wind velocity of the incoming air. It was found to be advantageous to secure the clean layer when the amount of air supplied is less than the amount of discharged air in the fire room. However, in the supply room, it is more effective to secure the clean layer when the amount of supplied air is larger than the amount of discharged air, as a longer boundary width gives rise to better performance. In addition, it is necessary to consider the amount of air supplied and discharged as a function of the kind of flammable material. Moreover, decreasing the air inlet wind speed and amount of incoming air is advantageous for securing the clean layer of the fire room.