공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

위탁급식업체 종사자의 하절기 작업복 착용 실태에 관한 연구 (A Survey on the Actual Conditions of Summer Working Uniforms for Contracted Foodservice Workers)

  • 이효현;염정하;최정화
    • 한국의류학회지
    • /
    • 제34권4호
    • /
    • pp.553-562
    • /
    • 2010
  • This survey investigates the conditions of summer working uniforms for contracted foodservice workers. The data were obtained from 67 workers through in-depth interviews (July 2005~October 2005). The results of study are as follows: The working environment changed to menu and cooking method (air temperature $28\sim37^{\circ}C$, humidity 72~86 %RH, radiant temperature $27\sim37^{\circ}C$, air velocity 0.14~0.37m/sec). They answered that the working environment has high temperatures, humidity, excessive noise, and liability to slide. The typical accidents were burns, cuts, slide, and ligament injuries in the workplace. Work duties consisted of cooking, serving food, washing, and cleaning up leftover food. All the employees carried out multi tasks. The primary working postures and motions were standing, crouching, and lifting. The female workers usually wore underwear (panty and brassiere), upper and lower work wear, aprons, waterproof-aprons, cotton-gloves, rubber-gloves, socks, and rubber-boots. The satisfaction of the uniform was relatively low for trousers and waterproof-aprons. The answer about the fit was generally "comfortable." They answered "back," "chest," and "head" were wet with perspiration during work. The uncomfortable parts were the crotch and neck. Questions concerning their satisfaction with the material of uniforms indicated a high rate of dissatisfaction, particularly for ventilation and absorbency. In case of the colors of the working uniform, workers preferred white color for the upper part, and black color for the lower part.

이동통신 주파수 대역에서의 동물 실험용 국부 노출 장치 개발 (Development of Local-Exposure Systems for In Vivo Studies at Mobile-Phone Frequency Bands)

  • 고채옥;박민영;도현정;김정란;정기범;백정기
    • 한국전자파학회논문지
    • /
    • 제17권5호
    • /
    • pp.451-460
    • /
    • 2006
  • 본 논문에서는 이동통신 주파수 대역인 PCS와 셀룰러 대역(PCS: 1,762.5 MHz, 셀룰러: 848.5 MHz)에서 전자파의 인체 영향 규명을 위해 동물 실험용 국부 노출 장치를 설계, 제작하였다. 제작된 노출 장치는 카루셀 형의 마우스용 국부 노출 장치로서 40마리의 마우스를 동시에 노출시킬 수 있으며, 피 실험체인 마우스에 스트레스가 없도록 조명, 환기, 소음 등 환경 조건을 적절히 고려하여 제작되었다. 노출 장치의 노출량 측정을 위해 온도 프로브를 이용한 SAR측정을 수행하였다. 마우스 카데바와 고체 팬텀의 머리 부분 내부의 3점에 대해 측정하였으며, 실제로 장기간의 노출에 이용되는 조건에서 시뮬레이션 결과와 잘 일치함을 확인하였다. 현재 제작된 노출 장치는 실제 마우스의 장기 노출 실험에 사용되고 있다.

은행원의 VDT작업에 따른 피로자각증상 (Industrial Fatigue due to Banking Operations with VDT)

  • 구정완;이승한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제24권3호
    • /
    • pp.305-313
    • /
    • 1991
  • In order to investigate industrial fatigue due to visual display terminal (VDT) work of banking operations the questionnaire survey for subjective symptoms of fatigue was carried out on 470 bank clerks who had been engaged in VDT work for various length of work hours. The questionnaires comprised three groups of 10 items each, representing dullness and sleepiness (level of cerebral activation), difficulty in concentration (level of motivation) and bodily projection of fatigue. The results were as follows : 1. Of the 30 items of questionnaires, the highest percentage was accounted for by 'eye strain' (51.5% ), followed by 'feel stiffness in the neck or the shoulders'(33.4%), 'feel a pain in the low back'(26.8%), 'whole body feels tired'(19.6%) and 'feel headache'(17.9%) in the order of sequence. 2. The average weighted score for the first group of questionnaire items (dullness and sleepiness) was the largest among three groups and was followed by 'the third cup (bodily projection of fatigue) and the second item group (difficulty in concentration) in the order of sequence, suggesting the heavier mental stress of VDT work in banking operations rather than physical burden. 3. In terms of the age and sex of workers, work duration and VDT work percentage, the difference in average weighted score was noted only between sex, the score of female being larger than that of male. 4. The complaint rates of subjective symptoms showed close associations with the subjective optimums of room temperature, ventilation, illumination and noise level. 5. The significant correlation was showed between age, work duration and item of 'whole body feels tired', between VDT work percentage and items of 'eye strain' and 'feel stiffness in the neck or shoulders' and between all items of subjective symptoms.

  • PDF

발코니 일체형 태양광발전시스템의 발전성능 분석 (Analysis of Performance of Balcony Integrated PV System)

  • 김현일;강기환;박경은;소정훈;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;목형수;지준근
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.302-308
    • /
    • 2011
  • 현재 철도 차량용 공조 시스템은 3상 AC 380V를 입력으로 받아 온/오프 제어만 하고 있어 효율 저감 및 소음 등의 문제점을 가지고 있으며 AC 전원 공급이 차단될 경우 blower 동작이 멈추는 문제점을 가지고 있다. 본 논문에서는 UPS 기능을 갖는 A/C blower용 인버터 시스템을 제안한다. 제안한 인버터 시스템은 입력으로 AC 전원과 DC 전원을 받아서 blower 구동용 유도전동기의 V/F 제어를 하며, CAN통신을 이용하여 속도, 모드 및 Soft-Start 시간 등을 제어한다. 또한 CAN 통신 고장시에는 정비용으로 RS-232통신을 이용해서도 제어할 수 있고 조작자가 직접 하드웨어적으로 제어할 수도 있어 기존의 문제점을 보완할 수 있다. 시뮬레이션과 실험을 통해 제안한 인버터 시스템의 유용성을 입증한다.

유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석 (An Analysis of Façade Panel Characteristics of UN Studio's Office Projects)

  • 고성학
    • 대한건축학회논문집:계획계
    • /
    • 제35권8호
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.

도심지의 대심도 수직구 발파에서 지반진동저감 시공 사례 (A Case Study of Deep Shaft Blasting for Reducing Ground Vibration in Urban Area)

  • 황남순;김경현;김정환;정민성;이형진;나경민
    • 화약ㆍ발파
    • /
    • 제39권2호
    • /
    • pp.15-26
    • /
    • 2021
  • 2013년부터 국산 전자뇌관이 출시되면서 많은 석산 및 건설현장에서 폭넓게 사용되어지고 있다. 도심지에서 이루어지는 SOC 프로젝트의 경우, 대부분 민원을 줄이기 위해 대심도로 설계가 이루어지는 추세이다. 대심도 굴착개발은 작업구 및 환기구 등의 시공에 많은 시간과 비용이 발생된다. 현장 인근에 보안물건이 위치한 경우, 기계식굴착공법을 적용하는 경우가 있으며, 이러한 기계식굴착방법은 암반의 강도 및 굴착장비의 성능에 따라 영향을 받는다. 기계식 굴착공법의 작업효율이 떨어지는 경우, 공사기간이 늘어나면서 비용이 증가하는 문제가 발생하고 있다. 본 사례는 도심지내 대심도 수직구 현장에서 기계식굴착공법으로 설계된 현장을 전자뇌관 발파공법으로 전환한 사례이다. 전자뇌관을 이용하여 발파소음과 진동에 대한 환경규제기준을 충족시키면서 공사기간을 단축시켰다.

포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석 (Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era)

  • 이세진;이원석;김은석;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

1인 거주 쉐어하우스 연구에서 만족도 조사항목 추출에 관한 연구 (A Study on the Deduction of Satisfaction Survey Factors in the Study of One-person Living Sharehouse)

  • 김소라;강미현;이민희
    • 한국농촌건축학회논문집
    • /
    • 제24권4호
    • /
    • pp.33-40
    • /
    • 2022
  • Sharehouse has been supplied as an alternative to solving the steadily increasing one-room housing problem of single-person households every year, and it is necessary to investigate the satisfaction of residents who actually live in sharehouse through P.O.E. Therefore, this study analyzed priror researches related to the existing one-person households, sharehouses, and satisfaction surveys, and summarized indicators with high relevance and frequency to derive satisfaction survey factors that can clearly evaluate the improvement architectural plan of sharehouses. As a result, it was classified into 4 items in the 'general information' category to investigate the status, housing rental type, and housing cost of the sharehouse, 15 factors in the 'peripheral environment' category to evaluate the safety, 3 factors in the 'community' category, and 17 factors in the space (facility) and service category. In the "General Information" section, the overall one-person housing satisfaction, desired sharehouse type, housing rental type, housing cost, and living expenses were reduced. In the "Surrounding Environment", accessibility to public office, accessibility to cultural facilities, accessibility to medical facilities, accessibility to work and school, convenience stores, noise pollution and safety. In addition, in the "community" section, it consists of interactions with various people, relationships with housemates and in the "space (facilities) and service" section, heating, waterproof, soundproof, ventilation, moisture and condensation blocking, facility management, interior, room size, built-in furniture, storage space, laundry, parking. Most of the scales for each factor were 5-point Likert scales, allowing evaluation of the degree of satisfaction, and some factors presented criteria to induce structured answers. Therfore, it is expected that the survey will be conducted on residents who actually live by deriving factors for the satisfaction survey of one-person households living in the sharehouse, and the current status of the sharehouse will be identified, and the degree of satisfaction will be analyzed to be used for research.