• Title/Summary/Keyword: Vehicle Fuel Tank

Search Result 99, Processing Time 0.019 seconds

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

CFD analysis of the effect of hydrogen jet flame in road tunnel (도로 터널 내 수소 제트 화염에 대한 CFD 해석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Hwiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.629-636
    • /
    • 2022
  • Domestic eco-friendly vehicles currently account for 5.8% of the total registered vehicles in Korea. Hydrogen vehicles, one of the representative eco-friendly vehicles, have grown rapidly as they have been expanded to the market based on the government's policy to boost the hydrogen industry. Therefore, it is time to expand the safety review of hydrogen vehicles in various directions according to the increase in supply. In this study, the effect of internal heat damage was analyzed when a jet flame was generated by a hydrogen car in a road tunnel. It was simulated using Fluent, and the amount of jet flame injection was selected in consideration of the hydrogen tank capacity of commercial hydrogen vehicles for road tunnels. In addition, the study was conducted with the direction of the jet flame and the nozzle distance from the tunnel wall as variables. From the results, when the jet flame erupted in the road tunnel, high radiant heat emission of more than 20 kW/m2 was generated in most areas within ±5 m in the longitudinal direction based on the vehicle (spray nozzle) and 5 to 7 m in the lateral direction based on the adjacent tunnel wall.

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (수술실 내의 아산화질소($N_2O$) 노출평가)

  • Baek, Jong-Bae;Uhm, Min-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.34-38
    • /
    • 2009
  • Nitrous oxide, which is used as an anesthetic gas, has been shown to be a chronic health hazard. It is necessary to monitor and control the nitrous oxide exposure of the operating theaters staff. In this study, N2O exposure level of the operating nurses is assessed with a GC-ECD. The nitrous oxide gas is collected on a molecular sieve 5A contained in a glass tube and desorbed for 12 hours at $100^{\circ}C$ in heating block. As a result of the test using GC-ECD, calibration curve's $R^2$ of $N_2O$ is 0.9992, LOD is $0.96{\mu}g$/injection, LOQ is $3.21{\mu}g$/injection, desorption efficiency is 94.78 4.50% in average and break through is within 10% compared with the concentration. The average concentration before operation is 5.12ppm and it is 42.3ppm during operation. There are a significant difference showing that the P value is lower than 0.05. Assessing exposure level to nitrous oxide based on nurses' working positions, the exposure levels do not show significant difference( P>0.005). And $N_2O$ in active sampling method is higher than passive sampling method(P<0.05).

  • PDF

Development of FCEV accident scenario and analysis study on dangerous distance in road tunnel (도로터널에서 수소차 사고시나리오 개발 및 위험거리에 대한 분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.659-677
    • /
    • 2022
  • Hydrogen is emerging as a next-generation energy source and development and supply of FCEV (hydrogen fuel cell electric vehicle) is expected to occur rapidly. Accordingly, measures to respond to hydrogen car accidents are required and researches on the safety of hydrogen cars are being actively conducted. In this study, In this study, we developed a hydrogen car accident scenarios suitable for domestic conditions for the safety evaluation of hydrogen car in road tunnels through analysis of existing experiments and research data and analyzed and presented the hazard distance according to the accident results of the hydrogen car accident scenarios. The accident results according to the hydrogen car accident scenario were classified into minor accidents, general fires, jet flames and explosions. The probability of occurrence of each accident results are predicted to be 93.06%, 1.83%, 2.25%, and 2.31%. In the case of applying the hydrogen tank specifications of FCEV developed in Korea, the hazard distance for explosion pressure (based on 16.5 kPa) is about 17.6 m, about 6 m for jet fire, up to 35 m for fireball in road tunnel with a standard cross section (72 m2).

Pogo Suppressor Design of a Space Launch Vehicle using Multiple-Objective Optimization Approach (다목적함수 최적화 기법을 이용한 우주발사체의 포고억제기 설계)

  • Yoon, NamKyung;Yoo, JeongUk;Park, KookJin;Shin, SangJoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • POGO is a dynamic axial instability phenomenon that occurs in liquid-propelled rockets. As the natural frequencies of the fuselage and those of the propellant supply system become closer, the entire system will become unstable. To predict POGO, the propellant (oxidant and fuel) tank in the first stage is modeled as a shell element, and the remaining components, the engine and the upper part, are modeled as mass-spring, and structural analysis is performed. The transmission line model is used to predict the pressure and flow perturbation of the propellant supply system. In this paper, the closed-loop transfer function is constructed by integrating the fuselage structure and fluid modeling as described above. The pogo suppressor consists of a branch pipe and an accumulator that absorbs pressure fluctuations in a passive manner and is located in the middle of the propellant supply system. The design parameters for its design optimization to suppress the decay phenomenon are set as the diameter, length of the branch pipe, and accumulator. Multiple-objective function optimization is performed by setting the energy minimization of the closed loop transfer function in terms of to the mass of the pogo suppressor and that of the propellant as the objective function.

Analysis of effect of hydrogen jet fire on tunnel structure (수소 제트화염이 터널 구조체에 미치는 영향 분석)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2021
  • A policy to expand the hydrogen economy has been established in Korea and the supply of FCEV is being expanded to realize a hydrogen society. Therefore, the supply of FCEV is expected to increase rapidly, and a solution to respond to accidents of FCEV is required. In this study, an experimental study was conducted to analyze the effect of the hydrogen jet flame generated by a FCEV on the inner wall of the tunnel and the characteristics of the internal radiant heat. For the experiment, the initial pressure of hydrogen tank was set to 700 bar, and the injection nozzle diameter was set to 1.8 mm in order to make the same as the conditions generated in the FCEV. In addition, a tunnel fire resistance test specimen having the same strength as the compressive strength of concrete applied to general tunnels of 40 MPa was manufactured and used in the experiment. The results were analyzed for the separation distance (2 m and 4 m) between the hydrogen release nozzle and the tunnel fire resistance test concrete. As the result, the maximum internal temperature of the test concrete was measured to 1,349.9℃ (2 m separation distance), and the radiant heat around the jet flame was up to 39.16 kW/m2.