• Title/Summary/Keyword: Variation of Rib

Search Result 54, Processing Time 0.028 seconds

Effect of Barrier Rib Height Variation on the Luminous Characteristics of AC PDP

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.91-94
    • /
    • 2003
  • We studied the effect of barrier rib height variation using ray-optics code incorporated with three-dimensional plasma simulation to analyze the effects of cell geometry for varying pressure conditions. The optimal barrier rib height decreased as the Xe partial pressure increased which resulted in due to the formation of local, strong sheath under high Xe partial pressure condition.

  • PDF

Thermal Characteristic Estimation of NC Machining Center Bed following Rib Structure (리브 구조에 따른 머시닝센터 베드의 열적 특성 평가)

  • Kim, Yang-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.746-752
    • /
    • 2010
  • Rib structure has been used to bed and column of machine tool to heighten weight stiffness ratio, cost performance and weight saving. In this paper the bed rib structure was estimated with thermal characteristics. Using superposition principle, machine tool designer can describe every complicated heat generation in the machine tool thermal source. As thermal characteristics, thermal deformation of guide rail and column and Maximum-minimum temperature variation were selected. The size, configuration and direction against the thermal loading surface operated to the thermal characteristics. The DB chart was made following rib structure estimating thermal characteristics. With superposition principle and DB chart, machine tool designer can prognosticate the thermal characteristics without FEM analysis to every bed rib structure.

Shape and Incidence of Rib Variations in Chest Radiographs (단순흉부촬영상 관찰되는 늑골 변이의 양상 및 빈도)

  • Joo, Ji-Seon;Bae, In-Young;Kim, Sung-Tae;Kwak, Seung-Min;Cho, Chul-Ho;Cho, Seung-Wook;Park, Chan-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • Background: The literature on variations of rib is limited. Very little has been written in the radiological journal of this country on the subject. It seemed of interest to investigate the nature and incidence of congenital variations in a series of routine chest roentgenograms. The topic of rib variations has not been covered extensively in the radiological journals in Korea. This has presented an opportunity to investigate the nature, type, shape and incidences of congenital rib variations in normal Korean adults from a series of routine roentgenograms. Methods: Chest radiographs of 5,000 adults, who visited our hospital for a routine check-up or for employment physical examinations from January 1996 to September 1998, were consecutively reviewed. The sex distribution consisted of 2,827 male males and 2,173 female females(ratio of 1.3:1) with the age range aged between 19 and 65 years(mean age: 34.6 years) were included. The chest PAs were analyzed for the presence, type, location, and shape of the rib variations. From this data the incidence of each type of variations was calculated. Results: Seventy-six of the 5,000 adults(1.52%), 63 male(2.23%) and 13 female(0.6%), showed 88 cases of rib variation(Table 1). The most common variation was the bifid rib(n=35), followed by hypoplasia of the rib(n=22), flaring of the rib(n=18), bridging of the ribs(n=7), cervical ribs(n=3), and fusion of between ribs(n=3)(Table 2). The bifid rib(Table 1) was found most frequent in the right fourth rib(12/35, 34.3%), followed by the left fifth rib(6/35, 17.1%) and right third rib(6/35, 17.1%). Hypoplasia of the rib was common in first rib(20/22, 90.9%). Flaring of the rib was common at fourth rib(8/18, 44.4%, right and left combined), and bridging between ribs was common between first and second rib(3/7, 42.9%). Conclusion : The percentage of incidence of rib variations in adults was 1.52%. Bifid rib was the most common variation, followed by hypoplasia, flaring, bridging, cervical rib, and fusion of ribs, in decreasing order.

  • PDF

Fatigue performance of rib-roof weld in steel bridge decks with corner braces

  • Fu, Zhongqiu;Ji, Bohai;Wang, Yixun;Xu, Jie
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.103-113
    • /
    • 2018
  • To study the effects of corner braces on fatigue performance of the U-rib and roof weld in steel bridge decks, the fatigue experiment was carried out to compare characteristics of the crack shape with and without corner braces. The improvement of fatigue life and stress variation after setting corner braces were also analysed. Different parameters of corner brace sizes, arrangements, and detail types were considered in the FEM models to obtain stress distribution and variation at the weld. Furthermore, enhancement of the fatigue performance by corner braces was evaluated. The results demonstrated that the corner brace could improve the fatigue life of the U-rib and roof weld, which exerted even no influence on the crack shape. Moreover, stress of the roof weld was decreased and the crack position was transferred from the root weld to U-rib and corner brace weld. It was suggested no weld scallop should be drilled on the corner brace. A transverse rib with lower height which was set between U-ribs was favourable for improvement of fatigue performance.

Effect of Punch Design and Flow Stress on Frictional Calibration Curve in Boss and Rib Test (보스-리브 시험 시 마찰보정선도에 대한 펀치형상 및 유동응력의 영향)

  • Yun, Y.W.;Kang, S.H.;Lee, Y.S.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.640-645
    • /
    • 2009
  • Recently, boss and rib test based on backward extrusion process was proposed to quantitatively evaluate the interfacial friction condition in bulk forming process. In this test, the tube-shaped punch with hole pressurizes the workpiece so that the boss and rib are formed along the hole and outer surface of the punch. It was experimentally and numerically revealed that the height of boss is higher than that of the rib under the severe friction condition. This work is focused on the effect of the punch design and flow stress on deformation pattern in boss and rib test. From the boss and rib test simulations, it was found that there is slight variation in both the heights of boss and rib according to the length of punch land, nose radius, and face angle. However the hole diameter of the punch and the clearance between the punch and die have a significant influence on the calibration curves showing the heights of the boss and rib. In addition, the effect of flow stress on the calibration curves was investigated through FE simulations. It was found that there is no effect of strength coefficient of the workpiece on the calibration curves for estimation of friction condition. On the other hand, the strain-hardening exponent of the workpiece has a significant influence on the calibration curve.

Effect of Punch Design and Friction Condition on Deformation Pattern in Boss and Rib Test (보스-리브 시험 시 펀치 형상 및 마찰 조건에 따른 변형 양상에 대한 연구)

  • Yun, Y.W.;Kang, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.332-337
    • /
    • 2009
  • Recently, boss and rib test based on backward extrusion process was proposed to quantitative evaluate the interfacial friction condition in bulk forming process. In this test, the tube-shaped punch with hole pressurizes the workpiece so that the boss and rib are formed along the hole and outer surface of the punch. It was experimentally and numerically revealed that the height of boss is higher than that of the rib under the severe friction condition. This work is focused on the effect of the punch design and friction condition on deformation pattern in boss and rib test. From the boss and rib test simulations, it was found that there is slight variation in both the heights of boss and rib according to the length of punch land, nose radius, and face angle. However the hole diameter of the punch and the clearance between the punch and die have a significant influence on the heights of the boss and rib. In addition, the effect of flow stress was also investigated on the deformation patterns through FE simulations.

  • PDF

Experimental Study on Transient Response According to Variation of Rib Height at Fuel Cell Plate (연료전지용 분리판의 리브 높이 변화에 따른 응답성 변화에 관한 실험적 연구)

  • Nam, Ki Hoon;Yun, Sung Ho;Han, Sung Ho;Choi, Nam Hyeon;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1009-1014
    • /
    • 2013
  • In the present study, using a variation of rib height, the transient response and the performance are investigated. The cell voltage is acquired according to the current density change($0.8A/cm^2$ to $1.0A/cm^2$) under same stoichiometry and relative humidity. The different level of undershoots appeared at the different clamping pressure(1.5MPa and 2.0MPa) and different rib height. At 1.5MPa clamping pressure, rib manufactured cut at $100{\mu}m$ height goes to steady state faster than reference plate and has lower maximum undershoot voltage. But performance is lower than reference plate due to increasing contact resistance.

The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom (흉부팬텀을 이용한 변형된 늑골 사방향 검사의 유용성에 관한 연구)

  • Um, Ki-Tae;Lee, Min-Su;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.525-532
    • /
    • 2018
  • This study is filmed by applying the axial angle variation of the X-ray tube instead of the patient's position change during the perimetric examination of the ribs. A Reference image with the rib oblique examination using a chest phantom and experimental images applied with a six-phase variation in the axial angle by increasing $5^{\circ}$ tube angle each from $5^{\circ}{\sim}30^{\circ}$ from the vertical incident direction of the chest phantom to the right horizontal axis were obtained. For the quantitative comparative evaluation of the images, SNR and CNR were calculated for regions of interest in the experimental images based on the reference image. Also, the left-right rib ratio in the reference image and the left-right rib ratio in the experimental images are measured and compared. As a result of the study, the experimental images with a tube angle of $25^{\circ}$ were best shown in the measurements of the SNR, CNR and left-right rib ratio compared to the reference image with a standard examination method. The modified rib examinations will consider useful, if it is difficult to maintain the patient's examination position.