• Title/Summary/Keyword: Variable switching frequency

Search Result 183, Processing Time 0.028 seconds

A Study on the Speed Control System of a 3 phase Induction Motor driven by the Full Bridge Inverter with a Low Pass LC Filter (저역통과 LC필터를 가진 전브리지형 인버터로 구동되는 3상유동전동기의 속도제어 시스템에 관한 연구)

  • 박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.538-550
    • /
    • 1998
  • The variable frequency and variable voltage AC source made by a conventional inverter which is composed of power semi-conductors includes much noises in sine wave due to high frequency switching of DC source. In this paper the 3rd low pass LC filter for a variable speed 3 phase induction motor driven by a full bridge inverter is introduced to solve the EMI problem by serious noise current. The utility of a modified 3rd order Butterworth LC filter is confirmed through FFT analysis of sine waves and noiseless ACsource can be obtained by the proposed LC filter. The speed of a 3 phase induction motor driven by a full bridge inverter with a LC filter is satisfactorily controlled by a digital PID controller under the condition of stepwise load and setpoint changes.

  • PDF

Dual Mode Packet Transmission Scheme using a Dynamic Switching Threshold in the IMT-2000 (IMT-2000에서 동적 스위칭 임계점을 이용하는 이중 모드 패킷 전송방식)

  • 김장욱;반태원;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.907-915
    • /
    • 2003
  • A very efficient packet transmission scheme is needed in the radio environment where radio resource is insufficient as compared with the environment of the wired communication. In general, dual mode packet transmission scheme is used broadly. Packets are transmitted through the dedicated or common chamois according to a switching criterion. The general criteria are the length and generation frequency of packet, that is, large and frequent packets are transmitted using a dedicated channel and small and infrequent packets are transmitted using a common channel. The performance of dual mode packet transmission scheme is closely related to the switching criteria. However, it is very difficult to find the optimal switching point because that is not fixed but variable according to the environment such as traffic load, length of generated packets, and the number of channels. In this paper, a new scheme for the dual mode packet transmission scheme using a dynamic switching threshold is proposed where the switching threshold is not fixed but variable according to the network environment. The performance of the proposed method is analyzed using a simulation. From the simulation results, it is shown that the performance of the proposed scheme is not very influenced by the network environment unlike the conventional dual mode packet transmission scheme.

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Steady-State Analysis of ZVS and NON-ZVS Full-Bridge Inverters with Asymmetrical Control for Induction Heating Applications

  • Yachiangkam, Samart;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.544-554
    • /
    • 2015
  • This paper presents a steady-state operation analysis of full-bridge series-resonant inverters focusing on the distorted load current due to low-quality-factor resonant circuits in induction heating and other applications. The regions of operation based on the zero-voltage switching (ZVS) and non-zero-voltage switching (NON-ZVS) operations of the asymmetrical voltage-cancellation control technique are identified. The effects of a distorted load current under a wide range of output powers are also analyzed for achieving a precise ZVS operating region. An experimental study is performed with a 1kW prototype. Simulation and experimental studies have confirmed the validity of the proposed method. An efficiency comparison between the variable frequency method and the conventional fixed-frequency method is provided.

A Study of Using Optimal Hysteresis Band Amplitude Tuning for Direct Torque Control of Induction Motor (최적의 히스테리시스 대역폭을 이용한 유도전동기 직접토크제어에 관한 연구)

  • Jeong, B.H.;Cho, G.B.;Choi, C.J.;Baek, H.L.;Hwang, J.S.;Kim, Y.M.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.598-601
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Evaluating Properties of Variable Sampling Interval EWMA Control Charts for Mean Vector

  • Kwon, Yong-Man;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.3
    • /
    • pp.639-650
    • /
    • 2005
  • Theoretical and numerical comparison have shown that variable sampling interval (VSI) charts are substantially more efficient than fixed sampling interval(FSI) charts in term of ATS(average time to signal). But the frequency of switching between different sampling intervals is a complicating factor in VSI procedures. VSI EWMA charts for monitoring mean vector of related qualify characteristics are investigated. To compare the efficiencies of the proposed charts, the performances are evaluated for matched FSI and VSI charts in terms of average time to signal(ATS) and average number of samples to signal(ANSS). For the switching behavior of the proposed VSI charts, average number of switches(ANSW) are also investigated.

  • PDF

Implementation of Harmonics Elimination and voltage Control of PWM Inverter for Induction Motor Driving (유도전동기 구동을 위한 PWM 인버터의 고주파제거 및 전압제어의 구현)

  • 박충규;전희종;정헌상;강문석;김국진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.1
    • /
    • pp.40-48
    • /
    • 1992
  • In this paper, th technique of particular harmonics elimination in three-phase PWM Inverter is discussed. And voltage control technique is derived whereby harmonics elimination is possible in variable voltage variable frequency three-phase I.M.. The required switching patterns are determined on Personal Computer and the results are stored in look-up table in EPROM for controlling the switching of the PWM Inverter. The results show that experiments are in good agreement with simulation based on the theory.

  • PDF

Design of Electronic Ballasts applied with Variable Frequency Driving Technique with regard for Thermal Degradation of Output Switches (출력 스위치의 열화를 고려한 주파수 가변 구동 방식의 전자식 안정기 설계)

  • Oh, Sung-Keun;Choi, Myoung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.157-161
    • /
    • 2000
  • The electronic ballasts for low pressure discharge lamps are produced and commercialized. However, the electronic ballasts for high pressure lamps are now in progress because of poor reliability and high cost. The major case of troubles with electronic ballasts are thermal destruction of semiconductor output switches due to non ideal i-v characteristics of switch. The loss converts to heat and rises the temperature of switch and it increases proportionally to switching frequency and value of current and voltage. This study shows the variable frequency ballasts which can suppress the heating of switches efficiently. It is used for the limitation the switch current and the rising temperature of switch by impedance variation of lamp inductor. As a result, initial warm-up time of the proposed ballasts was faster than that of magnetic ballasts about 90 msec. Power factor of tested ballasts follow as ; input and output average of magnetic ballasts are 93 [%] and 86 [%], respectively, And proposed ballasts are 97 [%] and 99 [%], respectively.

  • PDF