• 제목/요약/키워드: Variable Configuration

검색결과 214건 처리시간 0.029초

A Simple Cooperative Transmission Protocol for Energy-Efficient Broadcasting Over Multi-Hop Wireless Networks

  • Kailas, Aravind;Thanayankizil, Lakshmi;Ingram, Mary Ann
    • Journal of Communications and Networks
    • /
    • 제10권2호
    • /
    • pp.213-220
    • /
    • 2008
  • This paper analyzes a broadcasting technique for wireless multi-hop sensor networks that uses a form of cooperative diversity called opportunistic large arrays (OLAs). We propose a method for autonomous scheduling of the nodes, which limits the nodes that relay and saves as much as 32% of the transmit energy compared to other broadcast approaches, without requiring global positioning system (GPS), individual node addressing, or inter-node interaction. This energy-saving is a result of cross-layer interaction, in the sense that the medium access control (MAC) and routing functions are partially executed in the physical (PHY) layer. Our proposed method is called OLA with a transmission threshold (OLA-T), where a node compares its received power to a threshold to decide if it should forward. We also investigate OLA with variable threshold (OLA-VT), which optimizes the thresholds as a function of level. OLA-T and OLA-VT are compared with OLA broadcasting without a transmission threshold, each in their minimum energy configuration, using an analytical method under the orthogonal and continuum assumptions. The trade-off between the number of OLA levels (or hops) required to achieve successful network broadcast and transmission energy saved is investigated. The results based on the analytical assumptions are confirmed with Monte Carlo simulations.

국내 배전계통의 최적 개폐기 설치 기준(I) (The optimized standards and criteria for installing switches on distribution feeder)

  • 조남훈;오재형;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

$H_{\infty}$ 최적제어 이론을 이용한 도립진자의 견실한 보상기 설계에 관한 연구 (A Study on the Robust Compensator of An Inverted Pendulum Using $H_{\infty}$ Optimal Control Theory)

  • 김대현;정규홍;이석재;이교일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.213-218
    • /
    • 1991
  • A new model which contains the dynamics of the motor system and the kinematics of the timing belt system is derived for an inverted pendulum system in FAPA Lab. Generalized standard compensator configuration(SCC) which contains the variable design parameters Kl, K2, .., K5 is proposed so that any desired design specification can be achieved. The robust controller which has robust property against the influence of sensor noise, system parameter variation and model uncertainty is designed minimizing the H$_{\infty}$-norm of transfer function from exogenous input to controlled output. The method of solving the two Riccati equations in state space and determining the controller uses on iteration method where the unique stabilizing solution to two algebraic Riccati equation must be positive definite and the spectral radius of their product less than .gamma.$^{2}$. Some cases are derived by varying the design parameter for simulation on a digital computer and experimenting the H$_{\infty}$- controller on an analog computer. The design parameters of controller which satisfies the desired control specification is selected on the basis of the simulation result and experimenting. The reasonableness and validity of the simulation and the robustness of the controller is established.d.

  • PDF

태양열을 이용한 일이중 겸용 흡수식 냉온수기 동적성능 모사연구 (A Study of Dynamic Simulation of a Hybrid Absorption Chiller Utilizing Solar Power)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.967-972
    • /
    • 2009
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector also were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flowrate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

  • PDF

신규 가입자망 기술의 경제성 평가를 위한 망 구조모형과 그 응용

  • 류태규;이정동;김태유
    • 한국기술혁신학회:학술대회논문집
    • /
    • 한국기술혁신학회 2000년도 추계 학술대회(The 2000 Autumn Conference of korea Technology Inovation Society)(한국기술혁신학회)
    • /
    • pp.45-67
    • /
    • 2000
  • Broadband access technologies plays an important role in the national information infrastructure. In the evolution path of the information infrastructure, the relative economics of alternative access technology is the most critical determining factor. In this paper, we discuss the economics of local loop access technologies of existing technologies, such as, ADSL, HFC, and new PLC. To do this, we suggest appropriate configuration of access network system and its associated numerical equations. To modelize access network system and drive the numerical equations, we consider the DS (Double Star) and the T&B (Tree & Brench) architecture and analyse the adequate block diagram of each access system for each technology We introduce the density of subscriber as a key variable and the equation of allocating optimal number of cell in a service area. We analyze the relative economics of local loop architecture in two different situations, that is, urban and rural. From the empirical implementation, we found that for the case of urban area, where the cost of cable and infrastructure is not necessary, there is not much difference in the cost per one subscriber. However, for the case of rural region, we found that there is remarkable difference in the cost per one subscriber among technologies. Therefore we conclude that the economics of local loop architecture is depend on the density of subscriber and existing network infrastructures. we hope that this paper contribute to the optimal technology selection of consmer, technology Providers, and government.

  • PDF

Postoperative Evaluation of Funnel Chest - The role of radiologic indices -

  • 윤태진
    • Journal of Chest Surgery
    • /
    • 제25권12호
    • /
    • pp.1416-1421
    • /
    • 1992
  • There are many objective indices of operative outcome of funnel chest, but there has been only a few report about the postoperative change of these indices and which is best correlated with subjective outcome. From January 1989 to December 1991, 74 patients with funnel chest underwent Ravitch operation and radiologic evaluation was performed on the twenty patients whose operative outcome were satisfactory by Humphreys` criteria and postoperative chest X-ray were available. Variable radiologic chest idices such as deformity grade [DG], lower vertebral index [LVI], upper vertebral index [UVI] and configuration index [CI] were measured preoperatively and 1, 6, 12 and 18 months pos-toperatively. The mean value of preoperative DG, LVI, UVI and CI were 5.32, 0.3, 0.26 and 1.01 respectively, and postoperative chages were as follows; DG; 3.13, 3.66, 3, 72, 4.0, LVI: 0.22, 0, 24, 0.25, 0.25 UVI; 0.27, 0.27, 0.27, 0.27 CI; 0.69, 0.77, 0.76, 0.79. The increments of CI were within the 90 percent confidence limit of normogram in most cases, but it was not true for LVI and UVI. And the differences between the observed and expected values of CI did not change significantly through the postoperative periods, which was not the case in LVI. We concluded from these results that 1] DG, LVI and CI were increased slowly during the postoperative follow up periods but the increments of CI were usually within the normal limits and so 2] CI can be used as a objective index of satisfactory outcome.

  • PDF

부하추종형 고효율 지열히트펌프 시스템에 관한 연구 (1) (A Study on the High Efficiency Ground Source Heat Pump System (1))

  • 고득용;김욱중;최상규;장기창
    • 신재생에너지
    • /
    • 제1권4호
    • /
    • pp.30-37
    • /
    • 2005
  • Cycle simulation of Ground Source Heat Pump[GSHP] system was carried out to determine the design specification of basic components such as turbo compressor and heat exchangers. Part load operation characteristics of the designed GSHP system was estimated using the compressor and heat exchanger performance data. A 50RT class turbo compressor for GSHP system is now under development, in which R134a refrigerant is adopted as working fluid. The compressor with variable cascade diffusers is designed to work both in cooling and heating modes so that it can actively keep up with the climate change with high efficiency. The normal running speeds of the compressor are 59000rpm for heating mode and 70000rpm for tooling mode respectively. It has two identical impellers at both ends of the rotor so as to minimize aero-induced thrust force effectively. GSHP system was coupled with a vortical type heat exchanger, and heat gain and heat loss from ground were evaluated per a bore hole. For the optimal integration of the heat pump system, its header for circulating fluid was combined with the ground heat exchangers in parallel and series configuration.

  • PDF

주파수 영역 기반 쿼드로터 무인기 운동 모델 식별 (Dynamic Model Identification of Quadrotor UAV based on Frequency-Domain Approach)

  • 정성구;김성욱;정연득;김응태
    • 한국항공운항학회지
    • /
    • 제23권4호
    • /
    • pp.22-29
    • /
    • 2015
  • Quadrotor is widely used in variable application nowadays. Due to its inherent unstable characteristics, control system to augment the stability is essential for quadrotor operation. To design control system and verify its performance through simulation, accurate dynamic model is required. Quadrotor dynamic model is simply compared with conventional rotorcraft such as helicopter. However, the accurate dynamic model of quadrotor is not easy to develop because of the highly correlated aerodynamic effect of each rotor. In this paper, quadrotor dynamic model is identified from the flight data using frequency domain approach. Flight test of quadrotor is performed in closed loop configuration with stability augmentation system included. Frequency sweep input is applied in each of lateral, longitudinal, yaw and heave axis separately. The bare dynamic model is identified from the flight data of quadrotor responses and thrust measurement through Pulse Width Modulation(PWM) data. The frequency responses of identified model match well with those of flight data, and time responses of identified model for doublet input in each axis are also shown to agree with flight data.

플랜트 가용도 평가 시뮬레이터의 신뢰성 검증에 관한 연구 (A Study on the Reliability Verification of Availability Simulation for Complex Plant)

  • 이홍철;황인주;이현동
    • 한국CDE학회논문집
    • /
    • 제20권1호
    • /
    • pp.36-43
    • /
    • 2015
  • Recently, a number of evaluation studies on availability of plant were carried out. This study was conducted to verify of the reliability of a simulation with some variable such as configuration of process, failure probability density function and the number of iteration times for the natural gas liquefaction plant. The error rate of the KICT-RAM solution was evaluated as 0.03~1.79% compared with the result of the MAROS(commercial solution). And the error-rate change was observed in the range of 0.03~1.75 on the condition of the iteration times as 30, 100, 250. As a result the plant availability evaluation approach of KICT-RAM solution was verified as reasonable. However, the careful approach was required to use the solution because the error-rate increased according to iteration times change.

실시간 영상처리를 위한 영상 전처리 방법 및 하드웨어 구현 (Image Pre-Processing Method and its Hardware Implementation for Real-Time Image Processing)

  • 곽성인;박종식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.999-1002
    • /
    • 2013
  • 실시간 영상처리를 위해 다양한 시스템이 개발되고 있으며, 이들은 주로 고성능 프로세서에 의존한다. 하지만 이러한 영상처리 시스템은 상대적으로 낮은 성능의 모바일 시스템이나 저전력을 요구하는 시스템에는 적용하기 힘들다. 따라서 다양한 어플리케이션에 적용을 하기 위해서는 영상처리를 위한 좀 더 효율적인 방법이 필요하다. 본 논문에서는 상대적으로 낮은 성능의 시스템에서도 실시간 영상처리가 가능하도록 인트라 예측기 원리를 이용하여 영상의 처리 범위를 제한하는 전처리 방법을 고안하였고, 이러한 전처리기를 하드웨어 코어로 하는 시스템 구성을 제안한다. 또한 하드웨어 코어 구현 결과와 이를 이용한 영상 처리량 감소 방안을 제시한다.

  • PDF