밸브 스템계의 누유특성에 관한 실험적 연구 (Experimental Study on the Oil Leakage Characteristics of Valve Stem System)

  • 이일권;김청균
    • Tribology and Lubricants
    • /
    • 제20권4호
    • /
    • pp.204-208
    • /
    • 2004
  • This paper presents the oil leakage characteristics of the valve stem system in gasoline engines. For the oil leakage investigation, four study models have been prepared as functions of used poppet valve and used valve stem seal, used poppet valve and unused valve stem seal, unused poppet valve and used valve stem seal, and unused poppet valve and unused valve stem seal. With four models, the experimental study on the oil leakage has been investigated for the oil temperature, intake pressure, and camshaft speed. The experimental results show that the sealing performance of the valve stem seal plays an important role on the leakage of the valve stem system. And the appropriate replacement of a stem seal with used poppet valve shows good sealing performance in oil leakage in compared with a new valve system.

발전용 밸브 유체누설 측정 데이터의 통계적 평가 및 누설량 예측 연구 (Study on Statistical Analysis of Measured Fluid Leakage Data and Estimation of the Leakage Rate for Power Plant Valve)

  • 이상국;김대웅;김양석;박종혁;정훈
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.59-66
    • /
    • 2009
  • High temperature and pressure valves in power plant have been used for fluid flowing and leakage occurred owing to valve internal damage such as disc wear, crack and inserting of foreign objects etc. in these valves. Recently, multi-measuring technique applied both ultrasonic and acoustic method have been used for evaluation of valve internal leakage in order to raise measurement reliability. Therefore, we have performed various leakage tests using ultrasonic and acoustic measuring system and acquired leakage data for the various leakage conditions. In this study, we developed the estimation method of regression model through leakage data, and expectation method for valve opening ratio, which is directly proportion to leakage rate, using the established estimation model from the measured data, valve size and fluid pressure so as to enhance data reliability. As a result of this study, it was founded that expectation method of leakage rate by statistical analysis method is appropriate to valve leakage evaluation.

  • PDF

파일럿형 공기압 방향제어 밸브의 누설 고장판정 기법에 관한 연구 (Leakage Failure Determination Method of Pilot Pneumatic Directional Control Valve)

  • 강보식;김경수;장무성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.230-235
    • /
    • 2014
  • The failure modes of pneumatic directional control valves include leakage, wear of the spool seal, and sticking of the spool. Among them, the main failure mode of the valve is leakage. The leakage is caused by the wear of the spool seal. However, due to the characteristics of the seal material, the leakage rate is fluctuated a lot rather than constantly increased over time. If life analysis is performed using the first time data of leakage failure, predicted life cycles can be different from the real life cycles. This paper predicts life cycles of the pilot pneumatic directional control valve based on the three point moving average which considers the average of the fluctuating leakage rate.

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

압력제어밸브를 통한 누수량의 추정과 활용 (Leakage Control and Application Using the Pressure Reducing Valve)

  • 김신걸;김윤환;김경필;구자용
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발 (Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks)

  • 최종섭;;안효원
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

특수가스용기용 밸브의 안전성에 관한 실험적 연구 (Experimental Study on the Safety of a Valve for a Special Gas Cylinder)

  • 김청균
    • 한국가스학회지
    • /
    • 제17권3호
    • /
    • pp.14-19
    • /
    • 2013
  • 본 연구에서는 특수가스용기용 밸브의 안전성에 관한 실험적 연구를 수행하였다. 시험용 밸브는 특수가스용기에 부착되었던 것을 무작위로 수거한 것으로 가스누출 및 작동 안전성에 대한 시험을 실시하였다. 실험결과에 의하면, 밸브의 몸체, 나사 체결부, 안전판, 방출구, 스템부, 핸들에서 가스누출 안전성에 영향을 미칠 정도의 크랙, 마모, 부식, 변형이 발생하지 않았다. 다만, 핸들의 페인트 일부가 벗겨지고, PT나사와 몸체에서 녹이 국부적으로 형성되어 있지만, 가스누출 안전성에 영향을 미칠 정도는 아니었다. 또한, 탈거한 밸브에서 가스누출은 발생되지 않았다. 다만, 밸브스템의 영구변형과 오링의 마찰표면 일부에서 손상이 관찰되었다. 따라서, 탈거된 밸브의 가스누출 안전성을 보장하기 위해서 밸브시트와 오링 교체하는 것이 바람직함을 알 수 있다. 또한, 핸들의 조임력을 주기적으로 점검하는 것이 필요함을 알 수 있었다.

인공심방판막실패에 대한 임상적 고찰 (Reoperation for prosthetic valve failure -clinical analysis of 15 cases-)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

원전용 안전등급 밸브의 용접부 누설 클램핑 현장보수 기술 검토 (Preliminary Review of On-Site Clamping Repair Technology for Welding Part Leakage of Safety Related Valve in the Nuclear Power Plant)

  • 김기홍;김기수;정환석;장무경
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.52-59
    • /
    • 2023
  • The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

추진제 탱크 가압용 솔레노이드 밸브 개발 시험 (The Solenoid Valve Development Tests for Propellant Tank Pressurization System)

  • 김병훈;고현석;권오성;한상엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.813-816
    • /
    • 2011
  • 추진제 탱크 가압 시스템 적용을 위한 솔레노이드 밸브를 제작하여 작동시험 및 기밀시험을 수행하였다. 시험 결과 제작된 모든 밸브에서 작동 시간은 밸브 성능 요구 조건을 만족하고 있다. 그러나 기밀시험 결과 솔레노이드 밸브 내부에서 일부 누설이 있는 것을 발견하였다. 솔레노이드 밸브 분해를 통해 누설은 용접에 의한 Seat면의 손상이 주요 원인이라는 것을 확인하였다. 본 연구를 통해 추진제 탱크 가압용 솔레노이드 밸브 개발 가능성을 확인하였다.