• Title/Summary/Keyword: Value Improvement

Search Result 3,975, Processing Time 0.04 seconds

A Comparative Study on Protected Area Management in South Korea, Japan and China (한·일·중 3국의 보호지역 관리 비교연구)

  • Lee, Min-Ju;Lee, Gwan-Gyu;Sung, Hyun-Chan;Lee, Dong-Kun;Lee, Hyun-Woo;Kim, Joon-Soon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.1
    • /
    • pp.71-82
    • /
    • 2013
  • This study has been carried out with the purpose of coming up with suggestions for designation of domestic protection areas and improvement of their management through a comparative analysis of the systems of management of the protection areas in South Korea, Japan and China. Starting with the designation of natural reserves in 1962, South Korea has prepared legal systems for preserving ecosystems and biodiversity, while continuing to designate protected areas. As the state has so far monopolized the designation and management of all South Korean protection areas that take up 10.8% of its entire land area (as of Dec. 2011), with such persisting issues as multiple designations of one and the same area for protection, overlapping management authorities, and management of privately owned land in the protection areas. In Japan, which has protected area sizes and relevant legal systems similar to those in South Korea, the state provides the basic framework for management, while delegating most of the duties related to direct operation and management to specific municipalities. China, with an integrated administrative management of protected areas, has related government offices and municipalities responsible for the designation and management of individual protected areas. South Korea needs to provide a legally based support system that would further enhance the value of areal protection and contribute to the promotion of local economy and community.

A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater (재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

A Study on Improvement of Ventilation Efficiency of Multi-Stage Slot Hood (외부식 다단형 슬로트 후드의 효율 향상에 관한 연구)

  • Kim, Hyun Seok;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.204-212
    • /
    • 1993
  • This study was conducted to evaluate ventilation efficiency of 4-stage slot hood by variation of slot width, flow rate, hood size and baffle size. The slot velocity, control velocity and plenum velocity were related to slot width and the distance between source of contamination and hood. The results obtained from laboratory experiment for local exhaust ventilation systems were as follows ; 1. When slot widths were constant(equally changed) and the velocity was 6-10 m/s, the slot velocity from 1st slot to 4th slot gradually decreased. As the slot width-to-slot length ratio(WLR) decreased, the slot velocity of each stage increased. But if WLR value was less than 0.04, the slot velocity decreased. 2. When slot velocity exceeded 10 m/s with constant slot widths, the slot velocity of each stage was uniform. 3. When the slot velocity was uniform within 10 m/s and the first slot width was 14-20 mm, the slot width ratio between 1st slot and each of three other slots were 1, 1.25, 1.5 and 3.0, respectively. 4. The slot and plenum velocity were uniform when exhaust flow rate changed from 14 to $19m^3/min$ and there were no hood splitter vanes. 5. When the slot velocity at each stage was uniform, the control velocity at site 30 cm away from hood No.2 increased from 0.15-0.30 to 0.25-0.45 m/s and the control distance from 20 to 30 cm(about 1.5 times).

  • PDF

PARK Index and S-score Can Be Good Quality Indicators for the Preventable Mortality in a Single Trauma Center

  • Park, Chan Yong;Lee, Kyung Hag;Lee, Na Yun;Kim, Su Ji;Cho, Hyun Min;Lee, Chan Kyu
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.126-130
    • /
    • 2017
  • Purpose: Preventable Trauma Death Rate (PTDR) using Trauma and Injury Severity Score (TRISS) has been most widely used as a quality indicator in South Korea. However, this method has a small number of deaths corresponding to the denominator. Therefore, it is difficult to check the change of quality improvement for annual mortality, and there is a disadvantage that variation is severe. Therefore, we attempted to improve the quality of the mortality evaluation by reducing the variation by applying the PARK Index (preventable major trauma death rate, PMTDR) which can increase the number of denominator significantly. And the Save score (S-score) was also examined as another quality indicator. Methods: In the PARK Index, the denominator is number of all patients who have survival probability (Ps) larger than 0.25. Numerator is the number of deaths among these. The PARK Index includes only patients with ISS >15. The S-score is calculated in the same way as the W-score, but the S-score includes only patients with ISS >15, which is a difference from the W-score. Results: PARK Index decreased annually and was 12.9 (37/287) in 2014, 9.6 (33/343) in 2015, and 7.3 (52/709) in 2016. S-score increased annually and was -0.29 in 2014, 4.21 in 2015, and 8.75 in 2016. Conclusions: PARK Index and S-score improved annually. This shows that both quality indicators are improving year by year. PARK Index (PMTDR) has 9.5-fold increase in denominator overall compared to PTDR by TRISS. The S-score used only ISS >15 patients as a denominator. Therefore, there is an advantage that the numerical value change is larger than the W-score. In addition, S-score is not affected by the ratio of major trauma patients to minor trauma patients.

Synthesis of Mullite Powder from Alkoxides and the Properties of the Mullite-Zircocnia Composites (알콕사이드로부터 Mullite 분말의 합성 및 Mullite-Zirconia 복합체의 특성)

  • 함종근;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.2
    • /
    • pp.201-210
    • /
    • 1990
  • The mullite-15v/o ZrO2 composites were prepared by dispersing ZrO2-3m/o Y2O3 powders into the mullite matrix in order to improve the mechanical properties of the mullite. The densification and retention of t-ZrO2 in the matrix of synthetic mullite were also investigated. From IR spectroscopic analysis, the obtained amorphous SiO2-Al2O3 powder was observed to have Si-O-Al chemical bond in its structure which might result in the homogeneous mullite composition. The lattice parameter of the mullite powder calcined above 130$0^{\circ}C$ (a0=7.5468$\AA$) is nearly close to the value of stoichiometric mullite (71.8wt% Al2O3, a0=7.5456$\AA$). The sintering behavior, microstructure, flexural strength and fracture toughness of the mullite and mullite-15v/o ZrO2 composites have been studied. The mullite-15v/o ZrO2(+3m/o Y2O3) ceramics with relative densities of 96% were obtained when sintered at 1$600^{\circ}C$. The flexural strength and fractrue toughness of the composites sintered at 1$600^{\circ}C$(calcination temperature of mullite powders ; 125$0^{\circ}C$) had maximum values of 307MPa and 2.50MPa.m1/2, respectively. The fracture toughness improvement in the mullite-ZrO2 cmoposite is assumed to be resulted from the combined effect of the stress-induced phase transformation of tetragonal ZrO2 and the crack deflection due to microcracking by the monoclinic ZrO2 formation.

  • PDF

Effect of By-product (NH4Cl) on the Improvement of the Red Color Tone of Tantalum Nitride (Ta3N5) (탄탈륨 질화물(Ta3N5)의 적색도 향상에 미치는 NH4Cl의 영향)

  • Park, Eun-Young;Pee, Jae-Hwan;Kim, Yoo-Jin;Cho, Woo-Seok
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.583-586
    • /
    • 2009
  • The Tantalum nitride has attracted wide at attention as issues related to the toxicity of Cd-related materials. But in the titration process of Ta$Cl_5$ solution with $NH_4$OH, $NH_4$Cl, as a by product, was remained in the prepared Tantalum precursor. The tantalum precursor with $NH_4$Cl was nitrided by ammonolysis. The red color tone of $Ta_3N_5$ was reduced by the residual $NH_4$Cl reduce. Therefore, amorphous Tantalum precursor was prepared by filtering process with as hydrous ethanol to remove the $NH_4$Cl. In the case of using Tantalum precursor without $NH_4$Cl, we successfully synthesized the Tantalum nitride with good red color. The value of red color tone was improved from $a^*$=36.8 to $a^*$=53.0. The synthesized powder was characterized by XRD, SEM, the Nitrogen / Oxygen Determinator, TG-DTA, and the CIE $L^*a^*b^*$ colorimeter.

Improvement of Stimulus Pattern and Design of Discrimination System for Coincident ratio Elevation with Traditional Meridians (고전경락과의 부합율 향상을 위한 경혈자극방식의 개선 및 식별시스템의 설계)

  • Lee, Yong-Heum;Ko, Su-Bok;Jeong, Dong-Myong
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.22-31
    • /
    • 2003
  • Conventional stimulus patterns have used DC for discrimination of acupoint and meridian which is the basic object of diagnosis and medical treatment in oriental medicine. Those discriminate conduction points by stimulation on body skin with DC. But, it is insufficient to reliability in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper has extracted the optimal parameter of frequency and waveform in order to improve conventional pattern, and proposed the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, We proposes algorithm which is able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It can decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. We have compared the performance of system applying the extracted optimal parameter and algorithm. We have compared discrimination, coincident ratio of both conduction point and traditional acupoints by acupoint stimulation pattern. In the results, we confirmed reliability of SPAC stimulus pattern.

  • PDF

Compact Cascaded Quadruplet Bandpass Filter Using Modified Coaxial Cavity Resonator with Q-Factor Improvement (품질계수가 향상된 변형된 동축 공동 공진기를 이용한 다단 Quadruplet 대역통과 여파기)

  • Jang, Geon-Ho;Wang, Xu-Guang;Lee, Bo-Ram;Park, Nam-Shin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.966-977
    • /
    • 2015
  • This paper presents a novel modified coaxial cavity resonator and its application to bandpass filters with compact size and improved quality factor(Q-factor). The proposed resonator is made up of ${\Gamma}-shape$ or curved four inner conductive posts within a single cavity, which provides quadruplet to realize bandpass filter. No metallic walls inside the cavity are required, and thus the utilization efficiency of the cavity space is improved. As a result, the unloaded Q can be approximately 15 % higher in comparison to the conventional coaxial resonator, or more than 35 % volume saving can be achieved while maintaining the similar Q-factor value with the conventional designs. In addition, due to the multiple cross-coupling occurring within the cavity, including the source-to-load coupling, four flexible transmission zeros can be created to realize different filtering functions. Simulations as well as experimental results of four- and eight-pole filters are presented to validate this attractive design concept. Good agreement between measured and computed results is obtained.

A Study on Dewatering Characteristics of Anaerobic Digested Sludges (혐기성 소화조 오니의 탈수에 대한 요인분석)

  • 팽종인
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.2
    • /
    • pp.13-31
    • /
    • 1982
  • Factors affecting on dewatering characteristics of anaerobically digested or/and elutriated sludges were examined from 15 January 1982 to 30 April 1982, results obtained were as follows 1. Sludges, either anaerobically digested or/and elutriated sludges, which were produced at the Joong Rang Cheon Sewage Treatment Plant wore found to be compressive in its nature, coefficient of compressibility ranged from 0.83 for unelutriated and 1.10 for elutriated. 2. Dosage of FeC13 for the anaerobically digested sludges were difficult to establish for the most favorable dosage rate, though the filterability indicated linear improvement with increased dosage from dosing rate excess of over 15% in terms of dry solids by weight, under the conditions of this examination. Optimum filterability were obtained with 9~11% of $FeCl_3$ for elutriated sludges, and required CaO, as aids, were appeared to be 2.5~3.5 times that of the $FeCl_3$ at that point by weight. 3. The specific resistances for anaerobically digested sludges showed higher value than the elutriated one, being $11 \times 10^{12} ~ 20 \times 10^{12}$ cm/g with no chemical conditioning, and $2 \times 10^{12} ~ 11 \times 10^{12}$ cm/g with conditioned ($FeCl_3$ + CaO) contrast to $0.5 \times 10^{12} ~ 2.0 \times 10cm/g$ for the elutriated. 4. The strength of the alkalinities before and after elutriation were measured to 10,000 ~ 15,000 mg/l and 1,500 ~ 2,000mg/l respectively. These alkalinities affected greatly on the filterabilities together with concentration of the organic matters in the sludges. 5. The yields with 11% $FeCl_3$, by weight to the DS, on the elutriated sludges averaged to $14.7 kg/m^2.hr$, and $3.2kg/m^2.hr$ for unelutriated sludges. Which was 4.6 times of not elutriated sludges. Elutriated sludges without chemical conditioner added showed much better filterabilities than with 15% of $FeCl_3$ added to the anaerobically digested and unelutriated sludges.

  • PDF

The Effects of Melting Temperature and Holding Time on Critical Characteristics of HTSC Fabricated by Melting Method (용융온도와 유지시간이 용융법으로 제작한 고온초전도체의 임계특성에 미치는 영향)

  • Lim, Sung-Hun;Han, Tae-Hee;Park, Kyung-Kuk;Yim, Seong-Woo;Cho, Dong-Eon;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.154-161
    • /
    • 1998
  • The effects of melting temperature and holding time on the critical current density($J_c$) of $YBa_2Cu_3O_x$ based superconducting bulk fabricated by MPMG process were investigated. The amount of the formed $Y_2BaCuO_5$ phases increased with the melting temperature. However, the value of critical current density was highest at 1120 $^{\circ}C$. With this proper melting temperature, the effect of holding time on the critical characteristics was also investigated. In the case of Ag addition, the volume of the formed $Y_2BaCuO_5$ phase when the amount of Ag addition was 10 wt% and 20 wt% was observed to be highest at 20 minute and 40 minute respectively. But in the specimen without Ag, volume of $Y_2BaCuO_5$ phase increased as the holding time increased. The proper melting temperature and the holding time obtained were 1120 $^{\circ}C$ and 20 minute. The long holding time was not effective for the $J_c$ improvement as well as the formation of $Y_2BaCuO_5$.

  • PDF