가터스프링에 의한 튤립접촉자의 설계 고찰 (Design Review of Tulip Contactor by Garter Spring)

  • 조상순;박우진;안길영;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.242-245
    • /
    • 2003
  • A garter spring, which is a long, special, close-coiled extension spring with its ends joined to form a ring, is used in tulip contactor between vacuum circuit breaker and bus bar in switchgear. To carry short-time current and resist welding at the contact surface in the tulip contactor, the garter spring must transmits an uniform contact force to the contact surface through the contact chips arranged in the circumference of bus bar. In this paper, the system for measurement of the contact force by the garter spring is developed. Using the developed measurement system, the design of the connection structure including the garter spring is reviewed to obtain the uniform contact forces in all of contact chips.

  • PDF

스프링구동 캠에서 마찰과 스프링운동이 동적응답에 미치는 영향 (Influence of Spring Dynamics and Friction on Dynamic Responses in a Spring-Driven Cam)

  • 안길영;김수현
    • 대한기계학회논문집A
    • /
    • 제27권2호
    • /
    • pp.247-254
    • /
    • 2003
  • The paper presents the influence of spring dynamics and friction on dynamic responses in a spring-driven cam system. The characteristics of the friction on the camshaft are analyzed using the nonlinear pendulum experiment while the parameters of the friction model are estimated using the optimization technique. The analysis reveals that the friction of the camshaft depends on stick-slip, Stribeck effect and viscous damping. Spring elements are found to have much influence on the dynamic characteristics. Hence, they are modeled as four-degree-of-freedom lumped masses with equivalent springs. The appropriateness of the derived friction model and spring model is verified by its application to a vacuum circuit breaker mechanism of the cam-follower type.

한국형 고속전철의 VCB 제어 알고리즘 검증 (VCB Control Algorithm Verifications of Korean High Speed Train)

  • 전정우;정판규;이주훈;박도영;김용주;이병석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1362-1364
    • /
    • 2000
  • This paper presents the control algorithm verification process for VCB (Vacuum Circuit Breaker) of Korean High Speed Train. In order to enhance the reliability of the control algorithm, the verification process must be performed. The verification is conducted by comparing the pre-designed control algorithm with the pre-planned scenario by simulation tools such as SDL and MSC. This verification process will be applied to the other control algorithms of various control units of Korean High Speed Train.

  • PDF

고압전동식용 진단차식기의 스위칭써지 해석 및 연구 (A Study on the Reduction Method and the Analysis of VCB Switching Surge for High Voltage Induction Motor)

  • 이은웅;김종겸;김택수;이성철
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.761-769
    • /
    • 1994
  • VCB (Vacuum Circuit Breaker), with the strong arc extinction capability in switching the source of an induction motor, occurs the severe switching surge voltage which can cause the breakdown or the deterioration of motor insulation. Therefore, a method which reduces surge voltage across motor windings is necessary. So, it is analyzed that fast-rise-time surges resulting from VCB switching operations give rise to severe voltage stress on turn insulation. Additionally, the switching surge simulation algorithms using EMTP are developed, and C, R values of surge suppressor minimizing the steep-fronted stress in winding insulation surges are calculated.

고차단용량 진공인터럽터의 AMF 전극 비교연구 (Comparison of AMF Contacts for High Interrupting Capacity Vacuum Interrupter)

  • 김진수;최명준;류성식;김익모;최영찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1863-1865
    • /
    • 2004
  • As rise the demands for the protcetion of environment and the compactness of equipments, the movement brisks for replacing the circuit breaker of GIS(Gas Insulated Switchgear) to VI(Vacuum Interrupter). For these reason an increase in the interruption capability of VI is required. To satisfy these requirement, the academic and industrial worlds have been studying extensively for AMF(Axial Magnetic Field) contact, which is effective in interrupting large current over tens of kA, and introduced many kind of AMF contacts. However there are little effort to compare these contacts comprehensively, so it is difficult to choose most suitable shape for user's needs. In this paper, focusing unipolar type contact among various type of AMF contacts, we performed magnetic field analysis for several models designed in same dimension and compared the result and characteristics of each model in order to help deciding the direction for developing profitable VIs for interrupting large current.

  • PDF

Recent Advance in High Pressure Induction Plasma Source

  • Sakuta, T.
    • 한국표면공학회지
    • /
    • 제34권5호
    • /
    • pp.395-402
    • /
    • 2001
  • An induction thermal plasma system have been newly designed for advanced operation with a pulse modulated mode to control the plasma power in time domain and to create non-equilibrium effects such as fast quenching of the plasma to produce new functional materials in high rate. The system consists of MOSFET power supply with a maximum power of 50 kW with a frequency of 460 kHz, an induction plasma torch with a 10-turns coil of 80 mm diameter and 150 mm length and a vacuum chamber. The pulse modulated plasma was successfully generated at a plasma power of 30 kW and a high pressure of 100 kPa, with taking the on and off time as 10 ms, respectively. Measurements were carried out on the time-dependent spectral lines emitted from Ar species. The dynamic behavior of plasma temperature in a pulse cycle was estimated by the Boltzmann plot and the excitation temperature of Ar atom was found to be changed periodically from around 0.5 to 1.7 eV during the cycle. Two application regions of the induction thermal plasma newly generated were introduced to material processing with high rate synthesis based on non equilibrium effects, and to the finding of new arc quenching gases coming necessary for power circuit breaker, which is friendly with earth circumstance alternative to SF6 gas.

  • PDF

유한요소법에 의한 VCB 접속부의 대전류에 대한 전열해석 (Electro-thermal analysis of contacts and connections in VCB under high electric current by finite element methods)

  • 강우종;허훈;강경록
    • 대한기계학회논문집A
    • /
    • 제22권4호
    • /
    • pp.715-722
    • /
    • 1998
  • A large electric system of a vacuum circuit breaker(VCB) has been studied for the electro-thermal analysis by finite element methods. Since the heat generation in VCB causes not only energy loss but deterioration of the VCB system with oxidization of parts, the overheating of the system must be prevented. For the analysis, a finite element formulation is derived for both electric analysis and thermal analysis that are coupled together. Two sets of formulations are uncoupled after finite dimensional approximation. First, the electric potential is obtained for the entire field and scaled to the given electric current. The electric field obtained is then used to calculate the heat generation in the VCB system including contacts and connections for the calculation of the temperature distribution in the entire domain. The finite element analysis is carried out to study the effect of shapes and locations of contacts and connections. From the results, the existing VCB has been modified to enhance its capacity with reduction of heat generation and temperature elevation.

전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가 (Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 김주한;한상옥
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구 (A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker)

  • 이기선;박정철;추순남
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2503-2508
    • /
    • 2014
  • 본 연구는 진공차단기 기계식 보조접점(MOC)의 구조적인 취약성을 해결하기 위해 전자식 센서 기술을 이용한 전자식 보조접점(EOC) 개발에 선행되어야할 센서의 선정 및 노이즈 시험에 관한 것으로, 기존 기계적 보조접점(MOC)에서 발생하는 반복적인 떨림 및 반동 현상에 의한 접점 오동작을 최소화하는 제품을 개발하는 것을 최종 목표로 하였다. 실험 결과, 차단기 투입 및 개방시 개방시의 써지전압 상승속도가 투입시 보다 4.2배 빠른 것으로 측정되었고, 소음크기는 각각 120dB, 110dB로 측정되었다. 상용주파과전압 60kV를 인가하였을 때 진공차단기 투입 및 개방시 센서에서 출력되는 파형은 일그러짐이 없이 정상적으로 동작됨을 알 수 있었다. 그리고 150kV $1.2{\times}50{\mu}s$의 충격파를 인가하였을 때 센서의 투입 및 개방측 출력접점의 전압파형이 일그러짐이 없이 정상상태를 유지하였으며, 2500A의 전류를 인가하였을 때 자계 잡음을 측정한 결과, 전압파형이 일그러짐이 없이 정상적으로 동작하였다.