• Title/Summary/Keyword: Vacuum Level Control

Search Result 88, Processing Time 0.029 seconds

Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography (전자빔 가공기의 진공제어 밸브설계 및 특성평가)

  • Lee Chan-Hong;Lee Hu-Sang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

Performance analysis of feedback controller for vibratory gyroscope at various vacuum levels

  • Sung, Woon-Tahk;Lee, Jang-Gyu;Kang, Tae-Sam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1537-1541
    • /
    • 2003
  • In this paper, presented is a feedback control performance of vibratory gyroscope at various vacuum levels. Micro gyroscope, whose operation is based on the vibrating motion at the vacuum conditions, is highly influenced by the vacuum level of the operating circumstances. In general, we apply the feedback control scheme to the gyroscope in order to improve the performances of the sensor. And control performances of the gyroscope are related to those vacuum levels. So we need investigate the performances of the closed loop control at various vacuum conditions comparing with those of the open loop. The experimental results show that the sensitivity of the closed loop is less than that of the open loop especially in low vacuum conditions. Therefore, there should be trade-off between sensitivity and other sensor performances such as linearity, bandwidth when we apply feedback control to the gyroscope.

  • PDF

Basic Study for Distillation of Rocket Grade Hydrogen Peroxide (추진제 급 과산화수소 증류를 위한 기초 연구)

  • Chung, Seung-Mi;An, Sung-Yong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.67-70
    • /
    • 2009
  • Because many research using rocket grade peroxide is studied, distillation method for domestic production of rocket grade hydrogen peroxide is required. Distillation methods are very various and divided by feeding method, distillation time, distillation pressure, and so on. Among these, vacuum distillation is a suitable method for hydrogen peroxide. This method can reduce thermal decomposition and reaction with impurities. Distillation condition is determined by Raoult's law. Low vacuum level and vacuum level control are appeared as important problems of the experiment equipment, which are solved by using less leakage vacuum chamber and metering valve.

  • PDF

Domestic Construction of a Large Thermal Vacuum Chamber for Space Environment Simulation (우주환경모사를 위한 대형열진공챔버 국산화 구축)

  • Cho, Hyok-Jin;Moon, Guee-Won;Seo, Hee-Jun;Lew, Sang-Hoon;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.64-73
    • /
    • 2007
  • A Large thermal vacuum chamber (LTVC) for space environment simulation on large satellites was successfully developed and constructed by KARI (Korea Aerospace Research Institute) in Korea with a local company. This chamber has an effective diameter of 8 meters and depth of 10 meters, and is composed of vacuum system, thermal control system, and anti-vibration system. Temperature below $-190^{\circ}C$ is maintained over the thermal shroud wrapping a satellite under $3.7{\times}10^{-5}Pa$ ($5{\times}10^{-7}torr$) vacuum level, and optical test can be done in this chamber by seismic mass with $10^{-5}g_{rms}$ or lower vibration level. In addition, the shroud temperature can be increased up to $123^{\circ}C$ using halogen lamps. Chamber control program based on PLC (Programmable Logic Controller) could control this large thermal vacuum chamber automatically.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Effects of Packaging Methods on the Meat Quality of ${\alpha}$-Tocopherol Supplemented Broiler Chicks during Refrigerated Storage

  • Ryu, Youn-Chul;Rhee, Min-Suk;Lee, Moo-Ha;Lee, Sung-Ki;Kim, Byoung-Chul
    • Food Science and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.248-253
    • /
    • 2006
  • This study examined the effects of vacuum packaging and modified atmosphere packaging (MAP) on the meat quality of ${\alpha}$-tocopherol supplemented broiler chicks after prolonged refrigeration. The supplemented ${\alpha}$-tocopherol levels had no effect on the body weight and feed efficiency. The dietary treatments and packaging methods had no significant effects on the level of microbial growth, lightness, and the metmyoglobin content. The vacuum packaging showed the highest level of purge loss. The broilers supplemented with either 200 or 400 IU of ${\alpha}$-tocopherol had a lower level of malondialdehyde than the control group. The vacuum packaged meats from chicks fed the control diet showed the highest levels of lipid oxidation. The lipid oxidative stability was most improved in modified atmosphere (20% $CO_2$ + 80% $N_2$) packaged breast meat from the broilers supplemented with either 200 or 400 IU of ${\alpha}$-tocopheryl acetate.

The Sound Quality Evaluation and preference Analysis of Vacuum Cleaner (진공 청소기의 음질 평가 및 선호도 분석)

  • Jung, Dong-Hyun;Park, Sang-Gil;Fawazi, Noor;Lee, You-Yub;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The Conventional noise control attempts to simply reduce the level of product noise. But it is very straight forward way that we have consider human perception on noise. Since human listening is very sensitive to sound. Evaluation of the sound quality of a Vacuum Cleaner is studied base on human sensibility engineering. In this paper, we choose two Vacuum Cleaners that are sold in Korea and reduced noise control. Comparison Method is used to evaluate noise and preference of Vacuum Cleaner by steps. The sound quality of Vacuum Cleaner noise is analyzed by employing the subjective evaluation and by representing them in terms of the objective quantities. Semantic Differential Method is used to study sound quality Evaluation. To analyze the sound quality of Vacuum Cleaner noise, consider the coefficients of correlation between sound metrics and subjective rating. The linear regression models were obtained for the subjective evaluation and sound quality metrics.

  • PDF

Case study for Sound Quality Index of Vacuum Cleaner' Operating Noise (음질요소를 고려한 작동모드에 따른 진공청소기 출력소음의 음질 인덱스 사례 연구)

  • Jeong, Jae-Eun;Yang, In-Hyung;Park, Goon-Dong;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1223-1228
    • /
    • 2010
  • The conventional noise control attempts to simply reduce the level of product noise. But it is very straight forward way that we have considered human perception on noise. Since human listening is very sensitive to sound. Evaluation of the sound quality of a vacuum cleaner is studied base on human sensibility engineering. In this paper, we choose six vacuum cleaners that are sold in Korea and reduced noise control. The sound quality of vacuum cleaner noise is analyzed by employing the subjective evaluation and by representing them in terms of the objective quantities. Semantic differential method is used to study sound quality Evaluation. To analyze the sound quality of vacuum cleaner noise, consider the coefficients of correlation between sound metrics and subjective rating. The linear regression models were obtained for the subjective evaluation and sound quality metrics.

Phase Transitions in Cells and the Structure of Chromatins (세포에서의 상전이와 크로마틴 구조)

  • Kim, Hajin;Yoo, Jejoong
    • Vacuum Magazine
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2018
  • Phase transition is not unique to solid state systems or homogeneous molecular systems but it is also observed in highly heterogeneous biological systems. Phase transition and phase separation in cells are recently being found to be central to many biological functions by temporarily and locally controlling the storage and exchange of certain proteins and RNAs. There are also clues suggesting them to be playing pivotal roles in the spatial organization of chromosomes into topological domains and its time-dependent control. Here we introduce early efforts to explain at the molecular level how the spatiotemporal organization of chromosomes are programmed and modulated by the sequence and chemical modifications of the DNA. Continuing works may provide a physical framework to understand the molecular level control of chromosome structure and dynamics that determine the epigenetic state and the fate of the cells.

Temperature Uniformity Control of Wafer During Vacuum Soldering Process (진공 솔더링 공정 중 웨이퍼 온도균일화 제어)

  • Kang, Min Sig;Jee, Won Ho;Yoon, Wo Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 2012
  • As decreasing size of chips, the need of wafer level packaging is increased in semi-conductor and display industries. Temperature uniformity is a crucial factor in vacuum soldering process to guarantee quality of bonding between chips and wafer. In this paper, a stepwise iterative algorithm has been suggested to obtain output profile of each heat source. Since this algorithm is based on open-loop stepwise iterative experimental technique, it is easier to implement and cost effective than real time feedback controls. Along with some experiments, it was shown that the suggested algorithm can remarkably improve temperature uniformity of wafer during whole heating process compared with the ordinary manual trial-and error method.