Basic Study for Distillation of Rocket Grade Hydrogen Peroxide

추진제 급 과산화수소 증류를 위한 기초 연구

  • 정승미 (한국과학기술원항공우주공학과) ;
  • 안성용 (한국과학기술원항공우주공학과) ;
  • 권세진 (한국과학기술원 항공우주공학과)
  • Published : 2009.05.14

Abstract

Because many research using rocket grade peroxide is studied, distillation method for domestic production of rocket grade hydrogen peroxide is required. Distillation methods are very various and divided by feeding method, distillation time, distillation pressure, and so on. Among these, vacuum distillation is a suitable method for hydrogen peroxide. This method can reduce thermal decomposition and reaction with impurities. Distillation condition is determined by Raoult's law. Low vacuum level and vacuum level control are appeared as important problems of the experiment equipment, which are solved by using less leakage vacuum chamber and metering valve.

고농도 과산화수소를 이용한 연구가 활발해짐에 따라 과산화수소의 국내 생산을 위한 증류 방법에 대한 연구가 요구된다. 증류 방법에는 증류할 물질의 공급방식과 증류 회수, 증류 압력 등의 증류 조건에 따라 여러 가지 방법이 존재하며 과산화수소 증류에는 진공증류법이 사용된다. 진공 증류는 과산화수소의 열분해와 공기 중 입자와의 반응을 줄일 수 있다. 증류 조건은 Raoult's law를 이용하여 결정하였다. 실험 장치의 낮은 진공도와 진공도의 조절이 중요한 문제로 나타났으나 진공 챔버의 교체로 진공의 누설을 막아 진공도를 높였으며, 실험 장치에 정량밸브를 설치하여 진공도를 조절하였다.

Keywords