• Title/Summary/Keyword: VP8

Search Result 274, Processing Time 0.026 seconds

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Delayed Cerebral Abscess as a Shunt Complication and Endoscopic Removal of the Ventricular Catheter and Abscess

  • Shin, Dong-Seong;Hwang, Sun-Chul;Kim, Bum-Tae;Shin, Won-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.300-303
    • /
    • 2008
  • Shunt infections are a common complication of ventriculoperitoneal (VP) shunts, but the formation of a brain abscess related to a shunt system is very rare. A 44-year-old woman had a VP shunt inserted for hydrocephalus secondary to a subarachnoid hemorrhage. She suffered an episode of meningitis and sepsis 8 months after the shunt operation. After recovering from the meningitis, she complained of a loss of cognitive function. An enhancing mass was found in the frontal lobe, around the frontal horn of the lateral ventricle, and the ventricular catheter was embedded inside the mass. The ventricular catheter and cerebral abscess were removed using neuroendoscopy. We present an interesting case of a shunt-related brain abscess which illustrates the usefulness of neuroendoscopy.

Switching Power Module for a Small-Sized Electric Power Source (소형 전원용 스위칭 파워 모듈)

  • 김병철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1068-1073
    • /
    • 2004
  • 5 V/500 mA transless type power module was designed by using a semiconductor switching technique for a small-sized electric power source. It used voltage drop type chopper method, and is composed of switching circuit, control circuit, voltage detect circuit, and constant voltage circuit. The switching power module which is designed in this study, showed load regulation of 0.2 V, line regulation of 0.1 V, output ripple of 85 mVp-p, switching frequency of 64.7 kHz, maximum power efficiency of 58 %, and satisfied its reliability and EMC test.

A Study on Optimum Technics in Angiocardiography (심장혈관조영촬영(心臟血管造影撮影)의 촬영조건(撮影條件)에 대(對)한 검토(檢討))

  • Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.37-44
    • /
    • 1981
  • It is a experimental report to investigate optimum exposure technics in angiocardiography. Because of x-ray absorption and rapid voluntary motion in the heart region, it bound that discrimination ability of the exposed film is being decreased in ACG To circumvent these disadvantage it must be necessary to use short time exposure technics and also high capacity equipment in ACG. But in the case of using the low tube voltage to improve contrast on the exposed film, it will be result in a many difficulties in interpretation of the image due to increased contrast in vertebral images. Therefore the ranges 80 kVp to 90 kVp of could be suitable for the purpose of good contrast and an excellent discrimination ability and under this circumstance the optimum grid ratio for ACG was 8:1 to 12:1.

  • PDF

Genetic Characterization for Human Enterovirus Isolated from Busan Region in Korea (부산지역에서 분리된 엔테로바이러스의 유행양상 분석 및 유전자형 연구)

  • Kim, Nam-Ho;Min, Sang-Kee;Park, Eun-Hee;Park, Yon-Koung;Kwan, Sun-Mok;Jin, Seong-Hyeon
    • Journal of Life Science
    • /
    • v.20 no.6
    • /
    • pp.907-913
    • /
    • 2010
  • Human enteroviruses (HEV) are considered one of the major infectious causes of central nervous system infections such as aseptic encephalomeningitis in pediatrics. This study was focused on providing information related to genetic characteristics and diversities of HEV which prevailed between 2007 and 2009 in Busan, Korea. A total of 2,743 specimens were collected from children and screened for isolation of HEV by cell culture and RT-PCR. Among the specimins, 240 isolates were grouped into 21 different HEV serotypes using VP1 RT-PCR. The major etiological agents were CV-A6 and CV-B2 in 2007, E-6 and E-30 in 2008 and CV-B1 in 2009. The occurrence of HEV infections was the most frequent in the summer (May to August, 188 cases, 78.3%). Most of the isolates were identified from specimens from children under 10 years old, with the highest occurrence in the 2 to 4 year old range (15.2%). However, there were no significant differences between male and female children for the isolates. For analyzing genetic characterization, VP1 gene was amplified by RT-PCR and sequenced. The phylogenetic tree was established by Clustal W method using DNASTAR software. Using the sequence analysis of the VP1 region, it was classified into 2 groups; HEV-A and HEV-B. The HEV-A group contained 6 serotypes and sequences of 31 isolates were compared within each serotype. The HEV-B group contained 10 serotypes and the sequences of 41 isolates were compared within each serotype. Homology analysis of the VP1 region showed that the identity scores of HEV-A and B isolates were different. In conclusion, genetic divergences were observed among the isolates from children between 2007 and 2009 in Busan.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

10Gbps Demultiplexer using SiGe HBT (SiGe HBT를 이용한 10Gbps 디멀티플렉서 설계)

  • 이상흥;강진영;송민규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.566-572
    • /
    • 2000
  • In the receiver of optical communication systems, a demultiplexer converts to a single data stream with a highbit rate into several parallel data streams with a low bit rate. In this paper, we design a 1:4 demultiplexer using SiGe HBT with emitter size of 2x8um² The operation speed is 10Gbps, the rise and fall times of 20-80% are37ps and 36ps, respectively and the dissipation of power is 1.40W.

  • PDF

The Third-Order Multibit Sigma-Delta Modulator with Data Weighted Averaging (Data Weighted Averaging을 이용한 3차 멀티비트 Sigma-Delta 변조기)

  • 김선홍;최석우;조성익;김동용
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.107-114
    • /
    • 2004
  • This paper presents block and timing diagrams of the DWA(Data Weighted Averaging) to optimize a feedback time delay of the sigma-delta modulator. Through the MATLAB modeling, the optimized coefficients of the integrators are obtained to design the modulator. The fully differential SC integrators, feedback DAC, 9-level quantizer, and DWA are designed by considering the nonideal characteristics of the modulator. The designed third-order multibit modulator is fabricated in a 0.35${\mu}{\textrm}{m}$ CMOS process. The modulator achieves 75dB signal-to-noise ratio and 74dB dynamic range at 1.2Vp-p 825kHz input signal and 52.8MHE sampling frequency.

A Study on the Fabrication of a Membrane Type Micro=Actuator Using IPMC(Ionic Polymer-Metal Composite) for Micro-Pump Application (마이크로 펌프 응용을 위한 이온성 고분자-금속 복합체를 이용한 멤브레인형 마이크로 액추에이터 제작에 관한 연구)

  • 조성환;이승기;김병규;박정호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.298-304
    • /
    • 2003
  • IPMC(Ionic Polymer-Metal Composite) is a highly sensitive actuator that shows a large deformation in presence of low applied voltage. Generally, IPMC can be fabricated by electroless plating of platinum on both sides of a Nafion (perfluorosulfonic acid) film. When a commercial Nafion film is used as a base structure of the IPMC membrane, the micro-pump structure and the IPMC membrane are fabricated separately and then later assembled, which makes the fabrication inefficient. Therefore, fabrication of an IPMC membrane and the micro-pump structure on a single wafer without the need of assembly have been developed. The silicon wafer was partially etched to hold liquid Nafion to be casted and a 60-${\mu}{\textrm}{m}$ thick IPMC membrane was realized. IPMC membranes with various size were fabricated by casting and they showed 4-2${\mu}{\textrm}{m}$ displacements from $4mm{\times}4mm$ , $6mm{\times}6mm$, $8mm{\times}8mm$ membranes at the applied voltage ranging from 2Vp-p to 5Vp-p at 0.5Hz. The displacement of the fabricated IPMC membranes is fairly proportional to the membrane area and the applied voltage.