• Title/Summary/Keyword: VP7

Search Result 275, Processing Time 0.027 seconds

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

Expression of Recombinant Rotavirus Proteins Harboring Antigenic Epitopes of the Hepatitis A Virus Polyprotein in Insect Cells

  • Than, Van Thai;Baek, In-Hyuk;Lee, Hee-Young;Kim, Jong-Bum;Shon, Dong-Hwa;Chung, In-Sik;Kim, Won-Yong
    • Biomolecules & Therapeutics
    • /
    • v.20 no.3
    • /
    • pp.320-325
    • /
    • 2012
  • Rotavirus and hepatitis A virus (HAV) spread by the fecal-oral route and infections are important in public health, especially in developing countries. Here, two antigenic epitopes of the HAV polyprotein, domain 2 (D2) and domain 3 (D3), were recombined with rotavirus VP7, generating D2/VP7 and D3/VP7, cloned in a baculovirus expression system, and expressed in Spodoptera frugiperda 9 (Sf9) insect cells. All were highly expressed, with peak expression 2 days post-infection. Western blotting and ELISA revealed that two chimeric proteins were antigenic, but only D2/VP7 was immunogenic and elicited neutralizing antibody responses against rotavirus and HAV by neutralization assay, implicating D2/VP7 as a multivalent subunit-vaccine Candidate for preventing both rotavirus and HAV infections.

Fluorescence Characteristics of Gd2O2S:Tb3+ Intensifying Screen According to Increase of Tube Voltage (관전압 증가에 따른 Gd2O2S:Tb3+ 증감지의 형광특성)

  • Je, Jaeyong
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.261-264
    • /
    • 2014
  • In this study, $Gd_2O_2S:Tb^{3+}$ was used as the component of the intensifying screen, and this study aims at analysis of fluorescent feature depending on the increase of tube voltage using spectrometer. When the released fluorescence was measured according to the increase of tube voltage, blue, green and red was observed, among which, $^5D_4-^7F_5$ which is applicable to green, was strongest. In addition, when the fluorescent of 50 kVp and 120 kVp were compared, 50 kVp was proved to release only 9.56% fluorescence of 120 kVp. In case when tube voltage which is higher than 100 kVp is used for the X-ray using $Gd_2O_2S:Tb^{3+}$ intensifying screen, the amount and strength of the fluorescence reaching the film increase drastically, so attention is demanded to get images of proper concentration.

Cloning and nucleotide sequence analysis of VP7 genes of bovine rotaviruses isolated in Korea (국내에서 분리된 소 로타바이러스의 VP7 유전자 크로닝 및 염기서열 분석)

  • Kang, Shien-young;Jeon, Seong-jin;Chang, Kyeong-ok;Park, Yong-ha;Kim, Won-yong
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.2
    • /
    • pp.367-374
    • /
    • 1997
  • Bovine rotaviruses(A, 288, 55086 strains) isolated from fecal samples in Korea were propagated onto MA104 cells and were confirmed tentatively as G6, G8, and G10, respectively, by RFLP analysis. Full-length VP7 gene of these isolates was amplified by reverse transcriptase polymerase chain reaction(RT-PCR) using VP7 specific primers and cloned into TA vector. Nucleotide and deduced amino acid sequences of VP7 genes of the isolates were determined and compared with those of bovine rotavirus reference strains(NCDV; G6, UK; G6, Cody I-801; G8 and B223; G10). A, 288 and 55086 isolates showed high degree of nucleotide sequence homology with NCDV and UK(93% and 94%), Cody I-801(86%) and B223(97%), respectively, However, they showed 71~74% of nucleotide sequence homlogy with bovine rotavirus reference strains which belong to different serotypes. From the results of deduced amino acid sequence homology analysis, three isolates showed 94~96% of homology with the same serotype reference strains but 80~84% of homology with the different serotype reference strains. Three bovine rotavirus isolates, A, 288 and 55086 strains, were confirmed as G6, G8, and G10, respectively, by nucleotide and deduced amino acid sequence analysis.

  • PDF

A Fifteen-year Epidemiological Study of Ventriculoperitoneal Shunt Infections in Pediatric Patients: A Single Center Experience (소아 환자에서의 뇌실-복강 단락 감염의 역학적 고찰: 15년 간의 단일 기관 연구)

  • Kim, Yeon Kyung;Shin, Hyung Jin;Kim, Yae Jean
    • Pediatric Infection and Vaccine
    • /
    • v.19 no.3
    • /
    • pp.141-148
    • /
    • 2012
  • Purpose : Ventriculoperitoneal (VP) shunt insertion is an important treatment modality in children with hydrocephalus. VP shunt infection is a major complication and an important factor that determines the surgery outcome. This 15-year study was performed to evaluate the epidemiology of VP shunt infections in pediatric patients treated at our center. Methods : A retrospective review of medical records was performed in patients 18 years old or younger who underwent VP shunt insertion surgery from April 1995 to June 2010. Results : Three hundred twenty-seven VP shunt surgeries were performed in a total of 190 pediatric patients (83 females, 107 males). The median age of the patients was 2.4 years (range, 0.02-17.9 years). Having a malignant brain tumor was the most frequent cause for VP shunt insertion. The shunt infection rate was 6.7% (22/327) per 100 operations and 9.5% (18/190) per 100 patients, and the incidence rate was 0.45 infection cases per 100 shunt operations-year. The most common pathogen was coagulase-negative staphylococcus (n=7) followed by methicillin resistant Staphylococcus aureus (n=1). Ten cases were treated with vancomycin and beta-lactam antibiotic (cephalosporin or carbapenem) combination therapy and 7 cases were treated with vancomycin monotherapy. The median duration of antibiotic treatment was 26 days (range, 7 to 58 days). Surgical intervention was performed in 18 cases (18/22, 81.8%). Conclusion : Epidemiologic information regarding VP shunt infections in pediatric patients is valuable that will help guide proper antibiotic management. Additional studies on the risk factors for developing VP shunt infections are also warranted.

  • PDF

Multiple hTAFII31-binding motifs in the intrinsically unfolded transcriptional activation domain of VP16

  • Kim, Do-Hyoung;Lee, Si-Hyung;Nam, Ki-Hoon;Chi, Seung-Wook;Chang, Ik-Soo;Han, Kyou-Hoon
    • BMB Reports
    • /
    • v.42 no.7
    • /
    • pp.411-417
    • /
    • 2009
  • Transcriptional activation domain (TAD) in virion protein 16 (VP16) of herpes simplex virus does not have any globular structure, yet exhibits a potent transcriptional activity. In order to probe the structural basis for the transcriptional activity of VP16 TAD, we have used NMR spectroscopy to investigate its detailed structural features. Results show that an unbound VP16 TAD is not merely "unstructured" but contains four short motifs (residues 424-433, 442-446, 465-467 and 472-479) with transient structural order. Pre-structured motifs in other intrinsically unfolded proteins (IUPs) were shown to be critically involved in target protein binding. The 472-479 motif was previously shown to bind to $hTAF_{II}31$, whereas the $hTAF_{II}31$-binding ability of other motifs found in this study has not been addressed. The VP16 TAD represents another IUP whose pre-structured motifs mediate promiscuous binding to various target proteins.

Characterization of G9 genotype porcine rotavirus isolated in Korea (국내 양돈장에서 분리한 G9형 돼지로타바이러스의 특성)

  • Wang, Jun-Hui;Lee, Seung-Chul;Kang, Shien-Young
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.2
    • /
    • pp.83-90
    • /
    • 2012
  • Porcine rotaviruses are the most common causes of viral gastroenteritis in piglets around the world. The major G genotypes of porcine rotaviruses causing diarrhea were G4, G5 and G11 genotypes. Recently, G9 genotype rotaviruses were problemed at swine farms and frequently recognized from diarrheic piglets. In this study, a porcine rotavirus (PoRV-1) was isolated from piglet showing diarrhea using MA104 cells and confirmed as rotavirus by electron microscopy, genomic RNA electropherotyping and indirect immunofluorescence antibody tests. The nucleotide sequence of the VP7 gene of PoRV-1 was determined and compared with those of other genotype rotavirus strains from other parts of the world. Also, the nucleotide sequences of VP4, VP6 and NSP4 genes of PoRV-1 were determined and compared with those of other rotavirus strains from other countries. The results showed that the PoRV-1 isolate belonged to the G9 genotype and the P, I and E genotypes of PoRV-1 were P[23], I5 and E1, respectively. The Korean G9 PoRV-1 isolate and its nucleotide sequence data would be usefully used for the development of porcine rotavirus vaccines in near future.

Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan (소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가)

  • Park, Chan Rok;Choi, Jin Wook;Cho, Seong Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2014
  • Purpose: The purpose of study was to evaluate radiation dose for pediatric patients by changing tube voltage (kVp) and tube current (mA) at minimum conditions. By evaluating radiation dose, we want to provide dose reduction for pediatric patients and maintain good quality of SPECT/CT images. Materials and Methods: Discovery NM/CT 670 Scanne was used as SPECT/CT. Tube voltages are 80 and 100 kvP. Tube currents are 10, 15, 20, 25 mA. Using PMMA (Polymethyl methacrylate) Phantom, radiation dose which were calculated at center and peripheral dose and SNRD (Signal to Noise Ratio Dose) were evaluated. Using the CT performance phantom, spatial resolution was evaluated as the MTF (Modulation Transfer Function) graph. Jaszczak phantom was used for SPECT image evaluation by CNR (Contrast to Noise to Ratio). Results: Radiation dose using the PMMA phantom was higher peripheral dose than center dose about 7%. SNRD were 7.8, 8.2, 8.3, 8.8, 8.8, 9.9, 9.8, 9.6 for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. We can distinguish 35, 45, 70, 71, 52, 58, 90, 110 linepair for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA at resolution with MTF. CNR of SPECT images using CT attenuation map were 57.8, 57.7, 57.1, 56.7, 56.6, 56.7, 56.7, 56.7% for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. Conclusion: In this study, radiation dose for pediatric patients showed decreased low dose condition. And SNRD value was similar in all condition. Resolution showed higher value at 100kVp than 80kVp. for CNR, there was no significant difference. we should take additional study to prove better quality and dose reduction.

  • PDF

Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Electric Stimulus (전기자재에 대한 역돔의 심전도)

  • 한규환;양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.278-283
    • /
    • 2002
  • The response of electrocardiogram(ECG) of Nile tilapia, Oreochromis niloticus [Linnaeus] was studied to the electric stimulus which was given to a certain part of body The experiments were performed in such a way that three levels of electric stimulus (20, 30, 40 Vp ; 10 msec) were given to fishes with electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes in the water temperature of 16~18$^{\circ}C$ The results of the experiments were divided by day and night, and then were analyzed by experimental conditions as follows; 1. Nile tilapia reached a stable condition within 3 minutes after the electrode inserted into their bodies during anesthesia. In stable condition, the heart rates average was 45.8 beat/min during daytime and 45.0 beat/min at night. The action potentials average was 1.76 $mutextrm{V}$during daytime and 1.75 $mutextrm{V}$ at night. 2. The heart rates average by three levels of electric stimulus were \circled1 In the stimulus condition, the heart rates were 34.9 beat/min during daytime and 33.4 beat/min at night for the 20 Vp level, 36.8 bea/min during daytime and 36.0 beat/min at night for the 30 Vp level, and 38.0 beat/min during daytime and 36.4 beat/min at night for the 40Vp level. \circled2 In the recovery condition, the action potentials were 45.5 beat/min during daytime an 45.1 beat/min at night for the 20Vp level, 47.9 beat/min during daytime and 49.0 beat/min at night for the 30Vp level, and 51.4 beat/min during daytime and 50.7 beat/min at night for the 40Vp level 3. The action potentials average by three levels of electric stimulus were, \circled1 In the stimulus condition, action potentials were 2.54 $mutextrm{V}$ during daytime and 2.39 $mutextrm{V}$ at night for the 20 Vp level, 3.30 $mutextrm{V}$ during daytime and 2.30 $mutextrm{V}$ at night for the 30 Vp level and 6.05 $mutextrm{V}$ during daytime and 3.23 $mutextrm{V}$ at night for the 40 Vp level. \circled2 In the recovery condition, action potentials were 1.92 $mutextrm{V}$ during daytime and 1.95 $mutextrm{V}$ at night for the 20 Vp level and 2.78 $mutextrm{V}$ during daytime and 2.21 $mutextrm{V}$ at night for the 30Vp level and 3.6 0 $mutextrm{V}$ during daytime and 2.98 $mutextrm{V}$ at night for the 40 Vp level.

Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography (디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건)

  • Lee, Won-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.