경부선 전철화 구간에서의 귀선 전류 및 임피던스 예측 (Estimation of Traction return current and Impedance on Kyoungbu electrification line)

  • 김용규;양도철;유창근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.123-126
    • /
    • 2001
  • This study presents the simulation of the traction return current based on 2${\times}$25kV power supply system in order to determine the impedance bond intensity of impulse type track circuit on the Kyoungbo electrification line. The results of simulation enables us to measure the precise intensity of catenary current, returning to the substation through KTX (Korean Train Express) operated by 2${\times}$25kV power supply system with common earth network. In the wake of establishing 2${\times}$25kV and common earth network used in Korea for the first time, in particular, it is possible to determine the impedance bond intensity of impulse type track circuit, which is applicable to the Kyoungbo electrification line by specifying the relations among the traction return current, earth current, and catenary current.

  • PDF

센서용 세라믹 소체의 전기적 수명지수 산출 (Electrical Life Time Constant Estimation of Ceramic Element for Sensor)

  • 정주영;강동식;선종호;허종철;추영배;박정후
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석 (The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System)

  • 정금영;최선규;심건보;김경철
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.

CELP 음성부호화기 전송률 감소를 위한 음성신호의 V/UV 결정 알고리즘 (The V/UV Decision Algorithm for a Reduction of the Transmission Bit Rate in the CELP Vocoder)

  • 민소연;김현철
    • 한국항행학회논문지
    • /
    • 제11권1호
    • /
    • pp.87-92
    • /
    • 2007
  • 기존의 CELP 계열 보코더에서, 무성음에 대한 별도의 처리 없이 유성음과 동일하게 처리함으로써 합성음에서 음질의 저하 및 계산량과 전송률 측면에서 손실을 가져왔다. 본 논문에서는 에러율과 전처리 계산량을 최소로 할 수 있는 V/UV 분류기를 사용하여 CELP 보코더에서 전송률을 감소시키는 방법을 제안한다. 새로운 V/UV 분류기는 CELP 보코더에서 사용되는 LSP 파라미터의 주파수영역 분포도와 간격정보를 이용하여 V/UV를 결정하게 된다. 제안한 방법을 G.723.1 5.3kbps ACELP에 적용하여 성능 평가를 실시하였다. 실험결과, 음질의 저하 없이 약 6%의 전송률을 감소할 수 있었다.

  • PDF

765 kV 계통의 송전선로 거리에 따른 HSGS 적용에 관한 연구 (A analysis result on the application of HSGS to the 765 kV transmission line according to it's length)

  • 우정욱;심응보;김종화;김범진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2069-2072
    • /
    • 1999
  • The extended 765 kV system may have severe electrical transients according to the interconnection of transmission lines and have long transmission line over 250 km. So we need to analyze the transient phenomena to confirm the insulation coordination which is designed for 765 kV project step I. In particular, this paper shows the analysis results of secondary arc extinction by HSGS (high speed ground switch) application. The EMTP/MODELS were used to simulation study of secondary arc phenomena. We had confirmed the TRV(transient recovery voltage) and rated current of HSGS which will be used in the KEPCO 765 kV system.

  • PDF

The Elimination Characteristics by Impressed Voltage of Holography Grating in Chacogenide Thin Film

  • Lee Ki-Nam;Yeo Cheol-Ho;Yang Sung-Jun;Chung Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권6호
    • /
    • pp.219-222
    • /
    • 2004
  • This paper discovers that there are some peculiar properties that can remove holography grating, which was made in chacogenide thin film by impressed voltage. The thin films were used are $As_{40}Ge_{10}Se_{15}S_{35}$, and we use He-Ne laser in order to form thin films. I-V curved line in a thin film before a lattice was made has the critical point, about 3.7 V. Moreover, the I-V curved line increased current intensity at over 4 V after it made thin film. In addition, while holography grating is being made, and when it has the highest diffraction efficiency, a lattice can be deleted if put more voltage into it.

765 kV 송전선로의 풍소음 발생특성과 대책연구 (Characteristics of wind noise on 765kV Transmission Line and countermeasure against wind noise)

  • 이동일;신구용;추장희;김상범;이성두;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2005-2007
    • /
    • 2000
  • KEPCO 765 kV Transmission Lines where seasonal winds intersect to the direction of the transmission line route cause aeolian complaints from residents near the transmission lines due to 1.5 times sub-conductors numbers and about 2 times of tower height comparing 345 kV transmission lines. To decrease the wind noise generation, KEPRI developed two countermeasures. One is to install the Spiral Rod on wired 765 kV Cardinal conductor. The other method is to wire the Low Noise conductor which has salient part on the surface.

  • PDF

감전재해 분석을 통한 배전선로의 위험성 저감에 관한 연구 (A Study on the Risk Reduction of Distribution Line through Analysis of Electric Shock Accident)

  • 변정환;최상원
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.14-20
    • /
    • 2018
  • In this study, we analyze the current status of major disasters in distribution works and propose safety measures through the distribution live-line work method and electric shock risk assessment. The result of analyzing the ratio of electric shocks to the occurrence of industrial accidents in the recent 13 years shows that the death rate is higher than other industries, especially the construction industry occupying most of the disaster, and it is higher than the collapse disaster. We analyze statistic data of 101 victims selected as core words of live work, distribution line, pole and 22.9 kV in the investigation report of major accident of electric shock fatal from 2001 to 2014. The safety measure was established through the risk assessment of the distribution method using the standard model of the risk assessment based on the results of electric shock analysis on the distribution line. In order to prevent the electric shock accident which is recently being discussed, the risk assessment procedure were carried out in the above-mentioned 22.9kV special high voltage live-line operation method. We derived the risk reduction plan for the distribution line from the results of the major accidents statistic and demonstration of the line works.

154kV 송전선로 피뢰기 설치용 아킹혼 개발 (Development of Arc-horn to be mounted on 154kV Transmission Line Arrester)

  • 민병욱;김우겸;이북창;최한열;박재웅;금의연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2008
  • Overhead transmission lines are mainly crossing mountainous area. They are easily affected in weathers like typhoon, strong wind, lightning, heavy rain, or heavy snow. Sometimes these weathers cause transmission line faults. A lightning flashover is most often fault. Nowadays lightning density in KOREA is growing high and lightning flashovers occur more often. A lightning flashover on transmission line is mostly cleared by momentary operation of a circuit breaker, so power failure happens rarely. However, when both circuits trip simultaneously due to the lightning flashovers on double circuit transmission line, short time power failure and voltage drop happen. KEPCO has used transmission line arresters to avoid double circuit simultaneous trip out since 2003. And transmission line arresters cannot be installed with KEPCO's present metal fittings, so various fittings have been used for each transmission line arrester manufacturer. This paper introduces development and standardization of arc-horn and metal fittings for transmission line arrester which can be used for both existing lines and new lines in KEPCO.

  • PDF

저전력 OTP Memory IP 설계 및 측정 (Design of low-power OTP memory IP and its measurement)

  • 김정호;장지혜;김려연;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제14권11호
    • /
    • pp.2541-2547
    • /
    • 2010
  • 본 논문에서는 대기 상태에서 저전력 eFuse OTP 메모리 IP틀 구현하기 위해 속도가 문제가 되지 않는 반복되는 블록 회로에서 1.2V 로직 트랜지스터 대신 누설 (off-leakage) 전류가작은 3.3V의 MV (Medium Voltage) 트랜지스터로 대체하는 설계기술을 제안하였다. 그리고 읽기 모드에서 RWL (Read Word-Line)과 BL의 기생하는 커패시턴스를 줄여 동작전류 소모를 줄이는 듀얼 포트 (Dual-Port) eFuse 셀을 사용하였다. 프로그램 전압에 대한 eFuse에 인가되는 프로그램 파워를 모의실험하기 위한 등가회로를 제안하였다. 하이닉스 90나노 CMOS 이미지 센서 공정을 이용하여 설계된 512비트 eFuse OTP 메모리 IP의 레이아웃 크기는 $342{\mu}m{\times}236{\mu}m$이며, 5V의 프로그램 전압에서 42개의 샘플을 측정한 결과 프로그램 수율은 97.6%로 양호한 특성을 얻었다. 그리고 최소 동작 전원 전압은 0.9V로 양호하게 측정되었다.