• Title/Summary/Keyword: V-line

Search Result 2,154, Processing Time 0.044 seconds

Switching Power Module for a Small-Sized Electric Power Source (소형 전원용 스위칭 파워 모듈)

  • 김병철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1068-1073
    • /
    • 2004
  • 5 V/500 mA transless type power module was designed by using a semiconductor switching technique for a small-sized electric power source. It used voltage drop type chopper method, and is composed of switching circuit, control circuit, voltage detect circuit, and constant voltage circuit. The switching power module which is designed in this study, showed load regulation of 0.2 V, line regulation of 0.1 V, output ripple of 85 mVp-p, switching frequency of 64.7 kHz, maximum power efficiency of 58 %, and satisfied its reliability and EMC test.

A Swing Characteristics and Application Condition of the V type Suspension String Set (V련 현수애자장치의 횡진특성과 실선로 적용)

  • Sohn H.K.;Lee H.K.;Keum E.Y.;Min B.W.;Choi J.S.;Choi I.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.627-629
    • /
    • 2004
  • V type suspension string sets prevent instabilities from swing motion by the horizontal angle and by wind pressure. These installation conditions are controled mainly 3 items - normal swing angle by horizontal angle of line, unusual swing angle by strong wind, minimum vertical loads. We calculated and analysed that factors for the 765kV transmission line condition. And we were tested swing characteristics of V-string sets in real size test situation. So, we find to installation condition for the V type suspension string sets. This results will be used to design of V type suspension string set and to decision of the installation condition.

  • PDF

Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines (권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가)

  • Kang Dong-Sik;Kim Yong-Joo;Yun Youn-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

Forecasting Passenger Transport Demand Using Seasonal ARIMA Model - Focused on Joongang Line (계절 ARIMA 모형을 이용한 여객수송수요 예측: 중앙선을 중심으로)

  • Kim, Beom-Seung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.4
    • /
    • pp.307-312
    • /
    • 2014
  • This study suggested the ARIMA model taking into consideration the seasonal characteristic factor as a method for efficiently forecasting passenger transport demand of the Joongang Line. The forecasting model was built including the demand for the central inland region tourist train (O-train, V-train), which was opened to traffic in April-, 2013 and run in order to reflect the recent demand for the tourism industry. By using the monthly time series data (103) from January-, 2005 to July-, 2013, the optimum model was selected. The forecasting results of passenger transport demand of the Joongang Line showed continuous increase. The developed model forecasts the short-term demand of the Joongang Line.

A Study of Properties Eddy Current Sensor for 22.9kv Distribution Insulation Cable (22.9kV 배전선로 절연전선 검출용 와류탐상 센서 특성 연구)

  • Oh, Yong-Cheul;Kim, Tag-Yong;Lee, Kyeong-Seob;Jeong, Han-Seok;Yoo, Jae-Sik;Yang, Jung-Kwon;Lee, Jae-Bong;Lee, Keon-Hang;Kim, Chong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2140_2141
    • /
    • 2009
  • We used the eddy current sensor for a 22.9kV distribution power line insulation cable diagnosis. The insulation cable which is used in the 22.9kV distribution power line is having element wire from 6 to 18. Consequently, currently to ECT applications it has a limit in the distribution power line. We about under producing to apply in pick-up coil forms and the differential total coil form where becomes sum of zero in order to have. From measurement result, partial broken cable was confirmed 500 mV~980 mV changes from normal state.

  • PDF

The Analysis of the Discharging Characteristics on the Base Vacuum Level in a Vacuum In-line Sealing Process for High-efficiency PDP (고효율 PDP 제작을 위한 진공 인라인 실장에서의 초기 진공도에 따른 방전특성 분석)

  • Kwon Sang Jik;Jang Chan-Kyu;Kim Yong-Jae
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • We have examined the electrical and optical characteristics of the plasma display panel(PDP) produced by vacuum in-line sealing technology. We found that the luminous efficiency was decreased as the base vacuum level was increased. For the base vacuum level of $1\times10^{-3}$ Torr, the firing voltage was 235V at the discharge gas pressure of 400 Torr and the luminous efficiency was 0.8 lm/W at 180V sustaining pulse. However, for the base vacuum level of $1\times10^{-6}$ Torr, the firing voltage was reduced to 215V and the luminous efficiency was improved to 2.5lm/w. Finally, we demonstrated successfully the operation of tip-less PDP fabricated using vacuum in-line sealing method.

Analysis of the electrostatic induction effects on Parallel Circuit in 765kV test Line Analysis of electrostatic effects at 765kV test Line (수직 2회선 765kV 송전선로의 1회선 휴전작업 안전성검토)

  • Lee, S.D.;Lee, D.I.;Kwak, J.S.;Jeon, M.R.;Kweon, T.W.;Kim, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.358-360
    • /
    • 2002
  • 한국전력은 당진화력발전소로부터 신안성 변전소까지의 세계 최초로 수직배열 2회선의 765kV 송전선로를 건설하여 2002년 4월부터 1회선을 765kV로 가압하고 1회선은 345kV로 상업운전을 시작하였으며 2003년 이후 2회선을 모두 765kV 전압으로 가압 예정이다. 이러한 765kV 송전선로는 계통운영 측면에서 2회선 동시 휴전이 어려워 1회선 휴전 작업 및 향후 활선작업이 요구되는 중요선로이다. 765kV 1회선 휴전작업을 위해서는 765kV로 가압된 선로로부터 휴전선로의 작업자에게 발생될 수 있는 전기적 유도량에 대해 사전 검토하여 안전성을 확보하는 것이 필수적이다. 한국전력공사와 전력연구원은 1회선 휴전작업에 대한 안정성 검토를 위해 고창 실증시험선로를 이용하여 전기적 유도현상에 대한 시험을 실시하였다. 이 논문에서는 실증시험 선로를 모델로한 정전유도의 계산 결과와 실측치를 각각 비교, 검토하였다.

  • PDF

Characteristic Analysis of Gapped Surge Arresters for D.C. Railway Line (직류 전차선로용 공극형 피뢰기의 특성 분석)

  • 조한구;한세원;윤한수;천종욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.485-488
    • /
    • 2001
  • This paper provides the result of analysis of the structure and I-V characteristics of D.C. 1500 V surge arresters which were installed in railway line currently. As Porcelain housed surge arresters have unstable elements such as exploding and dispersion, so it is thought that the system is protected more stably with replacement of polymer housing. The adoption of gap mitigates the voltage stress which is degradation factor of surge arresters and the research is needed to enhance the life characteristic in additive and manufacturing process. Therefore, it is thought that the research should be continued to develop homemade the surge arresters for D.C. railway line as well as transmission line.

  • PDF

TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY

  • Veronese, Fabio;Kozlowsk, Tomasz
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.719-726
    • /
    • 2012
  • The object of this work is the validation and assessment of the TRACE v5.0 code using the scaled test ATLAS1 facility in the context of a DVI2 line break. In particular, the experiment selected models the 50%, 6-inch break of a DVI line. The same experiment was also adopted as a reference test in the ISP-503. The ISP-50 was proposed to, and accepted by, the OECD/NEA/CSNI due to its technical importance in the development of a best-estimate of safety analysis methodology for DVI line break accidents. In particular, the behavior of the two-phase flow in the upper annulus downcomer was expected to be complicated. What resulted was the need for relevant models to be implemented into safety analysis codes, in order to predict these thermal hydraulic phenomena correctly.

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF