• Title/Summary/Keyword: V shape

Search Result 1,232, Processing Time 0.035 seconds

Egg Development and Morphological Change of Larvae and Juveniles of the Starry Flounder, Platichthys stellatus (강도다리, Platichthys stellatus의 난발생과 자치어의 형태발달)

  • Byun, Soon-Gyu;Lee, Bae-Ik;Lee, Jong-Ha;Ku, Hak-Dong;Park, Sang-Un;Yun, Seong-Min;Hwang, Seon-Young;Kim, Yi-Cheong;Han, Hyung-Gyun
    • Korean Journal of Ichthyology
    • /
    • v.19 no.4
    • /
    • pp.350-359
    • /
    • 2007
  • The egg development and morphological change of larvae and juveniles of the starry flounder, Platichthys stellatus were observed in laboratory. Fertilized eggs of the species, 1.09~1.19 mm (mean $1.13{\pm}0.03mm$, n=50) in diameter, were floating, colorless, transparent in shape and lacked in oil globules. The eggs hatched out 121 hours after fertilization at water temperature $8.2{\sim}11.2^{\circ}C$. The size of the hatched larvae were 2.58~2.89 mm (mean $2.67{\pm}0.09mm$) in total length, their mouth and anus were not open yet and myotome number was 14+27=41. Melanophore and xanthophore appeared on the notochord and digestive organ and the margin of membrane fin, on the yolk sac and eyes were lacking in pigment cells. 5 days after hatching the larvae attained 4.30~4.97 mm (mean$4.74{\pm}0.21mm$) in TL, and their mouth and anus were open. 10 days after hatching the larvae transformed to postlarval stage and they were 4.67~5.75 mm in TL (mean $5.30{\pm}0.31mm$), and absorbing the yolk completely. Feeding activity increased as the mouth became larger. At 23 days, the larvae attained 6.69~8.82 mm in TL (mean $7.85{\pm}0.75mm$), and the right eye was started moving to the left side of the head. At 52 days, the juveniles attained 10.99~17.06 mm in TL (mean $13.50{\pm}1.67mm$). The right eye was moved completely onto the left side. All of the fins had completed set of the fin rays (D. 64~67: A. 45~51: P. 11: V. 6: C. 19).

Two Strains of Colletotrichum gloeosporioides Penz. Causing Anthracnose on Pepper Fruits (고추탄저병균 Colletotrichum gloeosporioides Penz.의 2계통)

  • Kim Wan Gyu;Cho Eui Kyoo;Lee Eun Jong
    • Korean Journal Plant Pathology
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 1986
  • Each of 48 monoconidial isolates of Colletotrichum gloeosporioides Penz. obtained from diseased fruits of pepper was classified into strain G or strain R based upon pathogenicity to green and red fruits, morphology of conidia, and cultural characteristics in potato dextrose agar. The strain G was designated for isolates to cause anthracnose symptoms both on green and red fruits. All isolates of the strain G produced conidia abundantly. but produced no perithecia and setae in PDA. Conidia of all isolates in the strain G were attenuated or round at one end. The optimum temperature for mycelial growth of strain G was $26-28^{\circ}C$. The mycelia of strain G in PDA appeared to be whitish when young, and turned to be dark in old culture. Symptoms on pepper fruits caused by the strain G were somewhat sunken to be circular to elliptical lesions. Yellowish conidial masse were observed at the center of lesions, and the lesions turned to irregular shape and to reddish brown color in the later stage of disease development. No setae were visible on the acervuli. The strain R was designated for isolates to cause anthracnose symptoms only on red fruits of pepper. All isolates of the strain R produce conidia, and perithecia of Glomerella cingulata (Stonem.) Spauld. & v. Sch. in PDA. Some isolates of the strain R produced setae in culture under fluorescent light. Conidia of all isolates in the strain R were round and blunt at the ends. The optimum temperature for mycelial growth of strain R was the same as that of strain G. The mycelial growth of strain R was faster than that of strain G in PDA. The mycelia of strain R in PDA appeared to be gray to dark. Symptoms on pepper fruits caused by the strain R were circular to irregular black ring-spots Short setae or no setae were visible on the acervuli.

  • PDF

CHARACTERISTICS OF THE PALATAL MORPHOLOGY OF THE CHILDREN WITH CROSSBITE IN MIXED DENTITION BY 3-DIMENSIONAL LASER SCANNER (3차원 스캐너를 이용한 혼합치열기 반대교합아동의 구개형태에 관한 연구)

  • Kim, Dong-Won;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.132-142
    • /
    • 2003
  • This study is performed to investigate the characteristics of the palatal morphology of the children with anterior crossbite in Hellman dental age IIIA by 3-dimensional laser scanner. Totally 40 study casts were taken; 20 were from children with crossbite and another 20 were from normal occlusion as a control. Each cast was scanned by 3 dimension laser scanner and shaped by the 3 dimension image by rapidform 2000 program(INUS, Korea). And finally it was calculated by Rhino 3D program(Rhinoceros, USA). The intercanine, intermolar cross-sectioned transverse plane and sagittal plane were measured. Due to the variations in palatal morphology, each group was standardized into 25mm, 35mm, 35mm. By sectioning standardized curves of the Palatal morphology per 1mm, the palatal depth of each point was calculated. Through these complex methods, the mean curves of the palatal morphology could be obtained and the values were statistically compared and evaluated by T-test with 95% of significance level. The results were as follows: 1. In the intercanine cross-sectioned transverse plane, the mean curve of palatal morphology of crossbite group was flatter V shape than that of control group, however, there was no statistical significance was found between two groups(P>0.05). 2. In the intermolar cross-sectioned transverse plane, the mean curve of palatal morphology of crossbite was deeper all over the area than that of control group, and the statistical significance was found in the middle area from point 8 to 21(P<0.05). 3. In the sagittal plane, the mean curve of palatal morphology of crossbite group was more deepening as approaching posteriorly than that of control group, and the statistical significance was found in all over the area(P<0.01).

  • PDF

Structural and Compositional Characteristics of Skarn Zinc-Lead Deposits in the Yeonhwa-Ulchin Mining District, Southeastern Taebaegsan Region, Korea Part I: The Yeonhwa I Mine

  • Yun, Suckew
    • Economic and Environmental Geology
    • /
    • v.12 no.2
    • /
    • pp.51-73
    • /
    • 1979
  • The zinc-lead deposits at the Yeonhwa I mine were investigated in terms of ore-forming geologic setting, structural style of ore control, geometry of individual orebodies, zoning, paragenesis and chemical composition of skarn minerals, as well as metal grades and ratios of selected orebodies. The Yeonhwa I mine is characterized by a large swarm of chimney type massive orebodies with thin skarn envelopes, boldly developed through a thick sequence of Pungchon Limestone, the overlying Hwajeol Formation, and the underlying Myobong Slate of Cambrian age. Nearly 20 orebodies of similar shape, but of varying size are arranged in a V-shaped pattern with northwest and northeast trends, clearly indicating an outstanding ore control by a conjugate system of fractures with these trends. Important orebodies are the Wolam 1, 2, 3, and 5 orebodies in the west, and the Namsan 1, 2, 3. and 5 orebodies in the east, among others. The Wolam 1 orebody, which was observed from the -360 level through the -240, -120, and 0 levels to the surface outcrops (totaling a vertical height of about 500m), shows a vertical variation in skarn mineralogy, ranging from pyroxene-garnet zone on the lower levels. through pyroxene (without garnet) zone on the intermediate levels, and finally to rhodochrosite vein on the upper levels and surface. Microprobe analyses of pyroxene and garnet on a total of 14 mineral grains revealed that pyroxenes are manganoan salitic in most samples, with downward increase of Fe and Mn, whereas garnets are highly andraditic, containing fractions of subordinate grossular with downward decrease of Fe. This indicates a reverse relationship of Fe-contents between pyroxene and garnet with depth. Ore minerals are major sphalerite, subordinate galena, and minor chalcopyrite. Sulfide gangue minerals include major pyrrhotite, and minor pyrite and marcasite of later age. Two types of variational trends in metal grades and ratios with depth are present on the plots of assay data from the Wolam orebodies: one is a steady upward increase in Pb, Zn, and Pb:Zn ratios, with a terminal decline at the top of orebody: the other is an irregular or sinusoidal change. The former is characteristic of chimney-type orebodies, whereas the latter is of vein· shaped orebodies. The Pb grades show large variations among orebodies and from level to level, whereas the Zn grades are relatively constand or less variable.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (V) (미세균열의 간격 분포를 이용한 결의 평가(V))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2017
  • Jurassic granite from Geochang was analysed with respect to the characteristics of the rock cleavage. The comprehensive evaluation for rock cleavages was performed through the combination of the 16 parameters derived from the enlarged photomicrographs of the thin section and the spacing-cumulative frequency diagrams. The results of analysis for the representative values of these spacing parameters with respect to the rock cleavage are summarized as follows. First, the above parameters can be classified into group I (spacing frequency (N), total spacing ($1m{\geq}$), constant (a), exponent (${\lambda}$), slope of exponential straight line (${\theta}$), length of line (oa') and trigonometric ratios ($sin{\theta}$, $tan{\theta}$) and group II (mean spacing (Sm), difference value between mean spacing and median spacing (Sm-Sme), density (${\rho}$), lengths of lines (oa and aa'), area of a right-angled triangle (${\Delta}oaa^{\prime}$) and trigonometric ratio($cos{\theta}$). The values of the 8 parameters belonging to group I show an order of H(hardway, H1+H2)

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Descartes' proofs for the existence of God (데카르트 신 존재증명의 의의)

  • Kim, Wan-jong
    • Journal of Korean Philosophical Society
    • /
    • v.141
    • /
    • pp.1-42
    • /
    • 2017
  • This paper's purpose is to seek to grasp how Descartes demonstrates proofs of God's existence on the basis of his works especially Meditations. To consider these points, I shall explore first, second, third proofs that are present in his works, and contents related to God. Descartes argues that there is idea of God within me, but it is God, which is first proof. On the basis of this fact, Descartes shows only God is the cause of thinking self who has idea of God(second proof), both of them are called Cosmological argument. To investigate this, at first he states that representative reality that is different from formal reality sets a kind of hierarchy, the degree of this reality is equally applied to cause and effect, consequently to the cause of my idea or existence(God). From Meditation V, third proof which is called Ontological argument, Descartes examined a supremely perfect God can't be separated from God's existence(perfection) just as surly as the certainty of any shape or number, for example triangle, namely it is quite evident that God's existence includes his essence. Through these processes I shall examine following points: the way of having Descartes' proofs of God's existence itself is not only exposed, God's existence who guarantees cogito ergo sum which is never doubted, despite doubting all things that is outside, is but also postulated; Proofs for the existence of God are an ultimate source of ensuring the clear and distinct perception of human reason, Descartes uses reason suitable for non-christians instead of faith suitable for Christians for these methods, which are similarities with the traditional views on the one hand, but nevertheless there are some of discontinuities establishing authority or power of the first philosophical principle to which God is subjected, on the other.