• Title/Summary/Keyword: V$_{}$ 50/

Search Result 5,470, Processing Time 0.043 seconds

The Study on the Separation of the Subsidiary Elements in Iron and Steel by Using Ion Exchangers (I). The Separation of Cations (이온교환수지에 의한 철 및 강의 분석에 관한 연구 (제1보) 양이온 성분의 분리)

  • Lee, Byoung-Cho;Park, Myon-Yong;Park, Kee-Chae
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.5
    • /
    • pp.346-352
    • /
    • 1973
  • The quantitative separations of a mixture containing equal amounts of each cation such as Mn(Ⅱ), Cr(Ⅲ), V(Ⅴ), Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ), and Fe(Ⅲ) are carried out by the elution through $35cm{\times}3.14cm^2$ column of cation exchange resin, $Dowex 50w{\times}12$. The eluents are a mixture of 0.6 M sodium chloride and 0.1 M sodium tartrate (pH = 2.00 and 4.50) for Fe(Ⅲ), V(Ⅴ), Cu(Ⅱ), Ni(Ⅱ) and Co(Ⅱ), and a mixture of 3 M sodium chloride and 0.1 M sodium tartrate (pH = 4.50) or a mixture of 0.7 M sodium chloride and 0.5 M sodium oxalate (pH = 4.50 and 5.00) for Mn(Ⅱ) and Cr(Ⅲ). The subsidiary cations in a standard iron mixture such as V(Ⅴ), Cu(Ⅱ), Ni(Ⅱ), Mn(Ⅱ) and Cr(Ⅲ) are separated together from the large amount of Fe(Ⅲ) through $15cm{\times}3.14cm^2$ column of the resin, $Dowex 1{\times}8$, by elution with the eluent of 4.0 M hydrochloric acid. A small amount of Fe(Ⅲ), however, is eluted together with Cu(Ⅱ). V(Ⅴ), Ni(Ⅱ), Mn(Ⅱ) and Cr(Ⅲ) eluted together are separated quantitatively through $10cm{\times}3.14cm^2$ column of the resin,$Dowex 50w{\times}12$. Cu (Ⅱ) and a small amount of Fe(Ⅲ) are separated quantitatively through $10cm{\times}3.14cm^2$ column of the resin, $Dowex 50w{\times}12$, by the elution with a mixture of 0.6 M sodium chloride and 0.1 M sodium tartrate (pH = 2.00 and 4.50) as an eluent. By the conditions obtained in the separations of the standard iron mixture, Fe(Ⅲ) and all of the subsidiary cations in steel are quantitatively separated.

  • PDF

A study on the radiation exposure of simple abdomen Radiation in Radiography (복부 단순 방사선 검사 시 피폭선량에 대한 연구)

  • Yeo, Jin-Dong;Kim, Mi-Sook
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.5-10
    • /
    • 2007
  • This study was performed to measure about exposure dose during simple abdmon radiation radiography. The exposure dose was measured by PDD, surface dose, respectively. The result was as followed: 1. When tube voltage were increased with 60-85kv, surface dose were increased. When FFD(focus film distance) at the 50-150cm and mAs were increased, surface dose were decreased. 2. The percentage depth dose(PDD) were appeared 50% below depth dose at 4cm with 60-75kv, and 6cm depth with 80-85kv, 5% below depth dose at 12cm with 60kv, and depth with 65-85kv. 3. The percentage forward scatter increased from 10% to 11.78% at the 60-85kv. The back scatter dose were increase from 25% to 37% at the 60-85kv. The side scatter dose were affected to heel effect.

  • PDF

Simulation and Synthesis of RISC-V Processor (RISC-V 프로세서의 모의실행 및 합성)

  • Lee, Jongbok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.239-245
    • /
    • 2019
  • RISC-V is a free and open ISA enabling a new era of processor innovation through open standard collaboration. Born in academia and research, RISC-V ISA delivers a new level of free, extensible software and hardware freedom on architecture, paving the way for the next 50 years of computing design and innovation. In this paper, according to the emergence of RISC-V architecture, we describe the RISC-V processor instruction set constituted by arithmetic logic, memory, branch, control, status register, environment call and break point instructions. Using ModelSim and Quartus-II, 38 instructions of RISC-V has been successfully simulated and synthesized.

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

Proper Light Intensity, Potting Media and Fertilization Level for Potted Hepatica asiatica Nakai (노루귀의 분화재배를 위한 적정 광도, 분용토 및 시비수준)

  • Jeong, Kyeong Jin;Jeon, Hyeon Sik;Chon, Young Shin;Yun, Jae Gill
    • Horticultural Science & Technology
    • /
    • v.33 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • This study was conducted to select proper light intensity, pot media, and fertilization level for potted Hepatica asiatica Nakai native to Korea. The plants were grown under various light intensities (shading rate, 52, 82, 90, 97%) imposed by shading net. Plants grown with 52% shading showed a low survival rate (65%). Survival rate increased as shading increased, with over 80% survival in shading above 90%. Growth indexes such as fresh weight and leaf number did not show any significant difference between shading treatments. Plants grown in a soil mixture of decomposed granite:fertilizer-amended media:Kanumatsuchi (60:10:30, v/v/v) or river sand:fertilizer-amended media:bark (50:20:30) showed over 85% survival. However, plants grown in a soil mixture of river sand:fertilizer-amended media:Kanumatsuchi (50:30:20) or upland:river sand (40:60) showed very low survival, below 60%. Leaf number and plant height were the highest in a soil mixture of decomposed granite:fertilizer-amended media:Kanumatsuchi (60:10:30) as well. To select a proper fertilization level for H. asiatica, hyponex solution diluted 1,000- or 2,000-fold were applied weekly or biweekly. The survival rate was lowest at weekly application with 1,000-fold diluted solution, and no significant difference was observed between other treatments. In conclusion, H. asiatica exhibits preferences for very low light intensity and soil with air permeability, and is adaptable to a broad range of fertilization levels.

Cytotoxicity of Ethanol Extract of Raphanuse Sativus on a Human Lung Cancer Cell Line (인체 폐암 세포주에 대한 무의 에탄올 추출물의 세포독성)

  • 임효빈;이건순;채희정
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.287-290
    • /
    • 2004
  • This study was desinged to investigate the cytotoxic effect of ethanonl extract of radish, Raphanuse sativus on human lung cancer cell lines (A-549) using MTT(3-〔4,5-dimethylthiazol-2-yl〕-2-yl)-2,5-diphenyltetrazolium bromide) assay. Radish trunk and radish root were extracted by a mixed solvent of water and ethanol (5 : 5, v/v) after drying, The extracts were used for anticancer activity assay. $IC_{50}$/ (50% inhibitory concentration) of radish trunk and radish root were 0.015% and 0.03%, respectively. Radish trunk extract showed higher anticancer activity than radish root extract at the same concentration of 0.01%.

A Study on the resistance of surface hardening treated Aluminum, Titanium alloy under the high velocity impact (표면 경화 처리된 Al, Ti의 고속 충격 저항성에 관한 연구)

  • 손세원;김희재;홍성희;김영태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.852-855
    • /
    • 2002
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of surface hardening treated Aluminum, Titanium alloy laminates, ballistic tests were conducted. In this paper, Anodized Al 5083-H131 alloy laminates and nitrified Ti (Gr.2) alloy laminates were used to achieve higher surface hardness. Surface hardness test were conducted using a Micro victor's hardness tester and thickness of surface hardening treated specimens was measured by video microscope. Resistance to penetration is determined by the protection ballistic limit($V_50$), a statistical velocity with 50% probability far complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_50$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_50$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests.

  • PDF

A Study on the fracture behavior of surface hardening treated aluminum alloy under the high velocity impact (고속충격을 받는 표면처리된 알루미늄 합금의 거동에 관한 연구)

  • 손세원;김희재;황도연;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.784-789
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and the resistance to penetration during ballistic impact of cold-rolled Al 5052 H34 alloy laminates, anodized Al 5052 H34 alloy laminates, and Al 5052 H34 alloy after cold-rolling, ballistic testing was conducted. In general, superior armor material is brittle materials which have a high hardness. Ballistic resistance of these materials was measured by protection ballistic limit(V50), a statical velocity with 50% probability for incomplete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed respectfully, resulting from V50 test and Projectile Through Plate(PTP) test at velocities greater than V50. PTP tests were conducted with 0$^{\circ}$obliquity at room temperature using 5.56mm ball projectile. V50 tests with 0$^{\circ}$obliquity at room temperature were also conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface Hardness, resistance to penetration, and penetration modes of Al 5052 H34 alloy laminates compared to those of cold-rolled Al 5052 H34 alloy laminates and anodized Al 5052 H34 alloy laminates anodized Al 5052 H34 alloy after cold-rolling.

  • PDF

A Study on the ballistic impact resistance and dynamic failure behavior of aramid FRMLs by high velocity impact (고속충격에 의한 아라미드 섬유강화 금속적층재의 방탄성능 및 동적파손거동에 관한 연구)

  • 손세원;이두성;김동훈;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.527-532
    • /
    • 2000
  • The armor composite material targets such as aramid FRMLs with different type and ply number of face material and different type of back-up material, were studied to determine ballistic impact resistance and dynamic failure behavior during ballistic impact. Ballistic impact resistance is determined by $\textrm{V}_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Also dynamic failure behaviors are respectfully observed that result from $\textrm{V}_{50}$ tests. $\textrm{V}_{50}$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during high velocity impact tests. As a result, ballistic impact resistance of anodized Al 5052-H34 alloy(2 ply) is better than that of anodized Al 5052-H34 alloy(1 ply), but Titanium alloy showed the similar ballistic impact resistance. In the face material, ballistic impact resistance of titanium alloy is better than that of anodized Al 5052-H34 alloy. In the back-up material, ballistic impact resistance of T750 type aramid fiber is better than that of CT709 type aramid fiber.

  • PDF

An Effect of surface treatment on a Protection Ballistic Limits in armor material (표면처리가 장갑재료의 방호한계에 미치는 영향)

  • 손세원;김희재;이두성;홍성희;유명재
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.126-134
    • /
    • 2003
  • In order to investigate the effect of surface treatment in Aluminium alloy and Titanium alloy which are used to armor material during ballistic impact, a ballistic testing was conducted. Anodizing was used to achieve higher surface hardness of Aluminium alloy and Iron plating in PVD(Physical Vapor Deposition) method was used to achieve higher surface hardness of Titanium alloy. Surface hardness test were conducted using a Micro victor's hardness tester. Ballistic resistance of these materials was measured by protection ballistic limit(V-50), a statical velocity with 50% probability penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed from the results of V-50 test and Projectile Through Plates (PTP) test at velocities greater than V-50. PTP tests were conducted with 0$^{\circ}$obliquity at room temperature using 5.56mm ball projectile. V-50 tests were conducted with 0$^{\circ}$obliquity at room temperature with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration. and penetration modes of surface treated alloy laminates are compared to those of surface non-treated alloy laminates. A high speed photography was used to analyze the dynamic perforation phenomena of the test materials.