• 제목/요약/키워드: Utility facilities

검색결과 204건 처리시간 0.026초

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

규모별 순환유동상 보일러의 열설계 변수 비교 평가 (Comparative Evaluation of Thermal Design Parameters of Different Sizes of Circulating Fluidized Bed Boiler)

  • 김태현;최상민
    • 한국연소학회지
    • /
    • 제16권4호
    • /
    • pp.16-22
    • /
    • 2011
  • The present paper discusses thermal design parameters of different sizes of circulating fluidized bed (CFB) boilers with capacities ranging from 2 MWe pilot scale boiler to a 600 MWe utility boiler. Physical boiler size and shape of furnace were identified and dimensional data have been summarized. By performing thermal design for each of the boilers, heat transfer surface area, furnace shape and size, and allocation of heat transfer surface for water-steam side heat absorption have been recalculated, and presented. Although boilers may have significantly different capacity, the facilities have common design parameters, when they are evaluated as basic thermal design processes. The significance of thermal design procedure is explicitly discussed.

A Modern Automatic Bus Transfer Scheme

  • Sidhu Tarlochan S.;Balamourougan Vinayagam;Thakur Manish;Kasztenny Bogdan
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.376-385
    • /
    • 2005
  • The proliferation of technology has made global conduction of business increasingly dependent upon the availability of reliable power. As a result, alternate power systems are being installed and expanded to protect the broadening scope of critical electrical loads. Bus transfer restores designated critical loads to an alternate source when utility derived service becomes inadequate or goes out of service due to any contingency. This paper describes the practices, requirements and implementation of bus transfer of motor loads to an alternate source of power. A new high-speed automatic bus transfer scheme is proposed which includes the development of a new algorithm for determining the type of bus transfer required and the realization of the scheme by using modem protection devices and intra-substation communication facilities.

토양오염 복원을 위한 EMPLUX를 사용한 새로운 방법에 대한 연구 (A Study on the New Method by EMPLUX for Soil-Remediation(1))

  • 김정성
    • 한국환경과학회지
    • /
    • 제16권12호
    • /
    • pp.1325-1335
    • /
    • 2007
  • The utility of soil-gas surveys is directly proportional to their accuracy in reflecting and representing changes in the subsurface concentrations of source compounds. Passive soil-gas vapor-phase is merely a fractional trace of the source, so, as a matter of convenience, the units used in reporting detection values from EMFLUX surveys are smaller than those employed for source-compound concentrations. According to the Leaking Underground Storage Tank(LUST) Program Annual Report, approximately 16 U.S. million dollars were spent for environmental site investigations at over 1,600 Underground Storage Tank(UST) sites and approximately over 1,000 acres of land was characterized and remediated in the State of Illinois in the year of 2003 alone. The main purpose of this study is to propose an idea to significantly reduce the site investigation cost by utilizing a passive soil-gas survey and conventional intrusive drilling method and to fully define the three dimensional characteristics of subsurface contamination from two industrial drycleaning facilities.

한국 소형(小型) 비행장(飛行場) 시설(施設)의 활용성(活用性) 증대(增大)에 관한 연구(硏究) (A Study on the Improvement for Availability of the Small Airport Facilities in Korea)

  • 이강석;강훈
    • 항공우주정책ㆍ법학회지
    • /
    • 제14권
    • /
    • pp.331-379
    • /
    • 2001
  • The purpose of this study is provide better suggestions to utilize the small aircraft by examining current situations of those airports. Then, the results of this study should help explain about the Availability of the airports for small aircraft in view of airplane exhibition, air-sports activity fields for aviation sports population, aviation theme park, and aviation-related education facility. This study examines current situations of the small airports for small aircraft which have been limited in their utility and compares the airports at the same level abroad. By examining these airports, this paper can make suggestions for the Availability of the small airports. Significance of the study lies in providing businessmen planning to invest the small airports and owners of airports with profitable consequences. At the macro level, it is expected to have a more effective development of land and an increase of aviation market value.

  • PDF

산업단지 내 근로자의 주거 선호도 연구 - 반월시화 산업단지를 중심으로 - (A Study of Industrial Complex Worker's Housing Preference)

  • 성상준;하권찬
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권3호
    • /
    • pp.17-25
    • /
    • 2011
  • The purpose of this study is basic research for demand forecasting of residence which will form in the new industrial complex. Our industrial complexes are important base of National economic development until 90's. But The industry complexes which confront facility which is old, Maintenance negligence and change of industrial system must change new shape from existing function of industrial complexes. The results of this study are that the present housing using condition are different at ages and Using intentions of staff facility are negative generally. These means that When starting the structure hightening, the utility system provision and public information of residence facilities in industral complex are necessary for workers. So, The key points of industry complex structure hightening are that the accurate recognition about demand and the development of financial support policy for young Income low-end workers do to make advance efficiently.

스마트 섹터 시스템 수동형 모델을 이용한 망구축과 그 효용성 (Building the Wireless Networks by Smart Sector System Passive Model(SCPM) and the Utility)

  • 김영만;박동민;이정도;임종민
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2003년도 하계학술대회
    • /
    • pp.29-32
    • /
    • 2003
  • 본 논문에서는 CDMA 이동통신 망에서 기존의 전통적인 섹터 분할 방식의 섹터간 traffic 불균형 현상에 따른 채널 자원의 비효율적 운용의 문제점 원인을 분석하고, 그 원인을 해소하기 위해 설계 고안된 스마트 섹터 시스템 수동형 모델의 소개, 설치 기법 그리고 이를 기지국에 적용하여 셀 내의 채널 자원 활용 효율이 개선된 결과를 소개하고자 한다.

  • PDF

통합운영학교 건축의 공용공간에 관한 연구 (A Study on the Public Space of Unification Management School Building)

  • 윤천근
    • 교육녹색환경연구
    • /
    • 제1권1호
    • /
    • pp.60-72
    • /
    • 2001
  • This study is show type classification, public space and space layout of unification management school. The type of unification management school classified the elementary and middle unification school, the unifying secondary school, the unifying elementary and secondary school. The result of this study analyze that ideal type is the unifying secondary school Public space of unification management school integrated support and management facilities. Variation and department classroom arc possible common utility. Space layout of unification management-school separate clearly entrance and buildings, Public spaces must be considerate smoothly use that they are located center of buildings.

  • PDF

초고층 주상복합아파트 거주자의 주거만족도 (The Residential Satisfaction of Residents in the High-rise Mixed-use Apartment)

  • 이수현;강순주
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.145-149
    • /
    • 2003
  • This study is to investigate residents' living satisfaction with high-rise mixed-use apartment complexes built in the structures of the reinforced concrete constructing and the steel framed reinforced concrete construction. The results of this study were obtained as follows: 1. Residents expressed below average satisfaction (below 3.0) with the common-area landscape and environmentally-friendly factors, children's playground and its facilities, community service for residents' by the management offices and the plan of utility. 2.According to the satisfaction of sound environment, residents of SRC group expressed above average satisfaction; it can be concluded that problems of causing noise around the residential area of the SRC and S groups were well solved in this study. However, satisfaction with the freshness of indoor air, humidity, and smell in the living quarters was rated low by the residents of SRC group. 3. High-rise mixed-use apartment complexes should accomodate families's life cycle, design an environmentally-friendly resting place in harmony with city life, and provide various communal programs for residents.

  • PDF

유효전력변동방식을 이용한 새로운 단독운전 검출기법 연구 (A Novel Active Anti-islanding Method using Effective Power Variation)

  • 유병규;정영석;미키히코 마츠이;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.213-215
    • /
    • 2006
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent the phenomenon, various anti-islanding methods have been studied. This paper proposes the variation method of inverter output current magnitude to prevent the islanding phenomenon as a novel method, which causes the large frequency variation of inverter output voltage after islanding. Unlike most active anti-islanding method deteriorating power quality, this novel method will have high performance of islanding detection and good power quality. For the verification of the proposed method, the simulated result and analyses are presented.

  • PDF