• Title/Summary/Keyword: Use Factor

Search Result 7,044, Processing Time 0.032 seconds

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

Determinants of women's contraceptive use in rural Ethiopia using Andersen's model (앤더슨 모형을 이용한 에티오피아 농촌지역 거주 여성의 피임실천 영향요인)

  • Sim, Boram;Nam, Eun Woo;Jin, Ki Nam
    • Korean Journal of Health Education and Promotion
    • /
    • v.33 no.2
    • /
    • pp.77-87
    • /
    • 2016
  • Objectives: This study was conducted to provide data in order to develop effective family planning programs by analyzing the factors which affect contraceptive use among women in Ethiopia. Methods: The community health survey was conducted on women of childbearing age. The research model was developed based on Andersen's Model. A total of 320 respondents were analyzed through Chi-square analysis, t-tests and logistic regression analysis. Results: Contraceptive prevalence rate was 43.1% and most of them were using modern and short-term methods. Among three factor categories, the need factor(unwanted pregnancy experience) was revealed as the most important factor, following enabling factor which was knowing the FP services in health center. Conclusions: These results lead to several conclusions. First, the results imply that programs should focus on women who are in the over 30yr. as well as the poorer economic group and urban residents. Second, to improve the effectiveness of the program, it is important to help them to be motivated themselves and to promote knowledge on various methods. Third, in terms of service delivery, community health workers are expected to take a crucial role. To improve the availability of services, they should provide practical services as those in health center.

Adjustment of Load Regression Coefficients and Demand-Factor for the Peak Load Estimation of Pole-Type Transformers (주상 변압기 최대부하 추정을 위한 부하상관계수 및 수용율 조정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Kyung-Ho;Moon, Jong-Fil;Lee, Jin;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This paper summarizes the research results of the load management for pole transformers done in 1997-1998 and 2000-2002. The purpose of the research is to enhance the accuracy of peak load estimation in pole transformers. We concentrated our effort on the acquisition of massive actual load data for modifying the load regression coefficients, which related to the peak load estimation of lamp-use customers, and adjusting the demand-factor coefficients, which used for the peak load prediction of motor-use customers. To enhance the load regression equations, the 264 load data acquisition devices are equipped to the sample pole transformers. For the modification of demand factor coefficients, the peak load currents are measured in each customer and pole transformer for 13 KEPCO (Korea Electric Power Corporation) distribution branch offices. Case studies for 50 sample pole transformers show that the proposed coefficients could reduce estimating error of the peak load for pole transformers, compared with the conventional one.

An On-Chip Differential Inductor and Its Use to RF VCO for 2 GHz Applications

  • Cho, Je-Kwang;Nah, Kyung-Suc;Park, Byeong-Ha
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.83-87
    • /
    • 2004
  • Phase noise performance and current consumption of Radio Frequency (RF) Voltage-Controlled Oscillator (VCO) are largely dependent on the Quality (Q) factor of inductor-capacitor (LC) tank. Because the Q-factor of LC tank is determined by on-chip spiral inductor, we designed, analyzed, and modeled on-chip differential inductor to enhance differential Q-factor, reduce current consumption and save silicon area. The simulated inductance is 3.3 nH and Q-factor is 15 at 2 GHz. Self-resonance frequency is as high as 13 GHz. To verify its use to RF applications, we designed 2 GHz differential LC VCO. The measurement result of phase noise is -112 dBc/Hz at an offset frequency of 100 kHz from a 2GHz carrier frequency. Tuning range is about 500 MHz (25%), and current consumption varies from 5mA to 8.4 mA using bias control technique. Implemented in $0.35-{\mu}m$ SiGe BiCMOS technology, the VCO occupies $400\;um{\times}800\;um$ of silicon area.

The Effect Factors on the Purchase Intension of Smart Car as of High Innovative Technology and Product; Consumer's Individual Attributes, Perceived Benefit and Switching Cost

  • Ahn, Yeon S.
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.9
    • /
    • pp.113-119
    • /
    • 2016
  • In this paper, a research model is proved empirically which includes factors related on the purchase intention of smart car as high innovative product in advance of commercialization. As one of relating to consumer's expectation benefit factors, individual attribute factor includes product knowledge, individual innovativeness, and sociality. Consumer's expectation benefit factor includes perceived ease-of-use, usefulness, and enjoyment. As of switching cost variables, there are financial, uncertainty, relational and psychological switching costs factors. Analysis were performed using data from the 257 respondents as random sampling among potential consumers. Purchase intention were affected by individual innovativeness mediated by perceived enjoyment, and individual sociality by perceived ease-of-use and enjoyment also. Relational switching costs factor was only a significant control variable between purchase intention with consumer's expectation benefit factor. This result presents some implications for making the new smart car's detail concept and marketing strategy related to targeting the consumer as high innovative product and technology firms including smart car makers.

Type Drive Analysis of Urban Water Security Factors

  • Gong, Li;Wang, Hong;Jin, Chunling;Lu, Lili;Ma, Menghan
    • Journal of Information Processing Systems
    • /
    • v.16 no.4
    • /
    • pp.784-794
    • /
    • 2020
  • In order to effectively evaluate the urban water security, the study investigates a novel system to assess factors that impact urban water security and builds an urban water poverty evaluation index system. Based on the contribution rates of Resource, Access, Capacity, Use, and Environment, the study adopts the Water Poverty Index (WPI) model to evaluate the water poverty levels of 14 cities in Gansu during 2011-2018 and uses the least variance method to evaluate water poverty space drive types. The case study results show that the water poverty space drive types of 14 cites fall into four categories. The first category is the dual factor dominant type driven by environment and resources, which includes Lanzhou, Qingyang, Jiuquan, and Jiayuguan. The second category is the three-factor dominant type driven by Access, Use, and Capability, which includes Longnan, Linxia, and Gannan. The third category is the four-factor dominant type driven by Resource, Access, Capability, and Environment, which includes Jinchang, Pingliang, Wuwei, Baiyin, and Zhangye. The fourth category is the five-factor dominant type, which includes Tianshui and Dingxi. The driven types impacting the urban water security factors reflected by the WPI and its model are clear and accurate. The divisions of the urban water security level supply a reliable theoretical and numerical basis for an urban water security early warning mechanism.

On Equipment Replacement Models (장비교체모델에 대하여)

  • 박순달;이창훈;박철호
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.5 no.1
    • /
    • pp.31-38
    • /
    • 1980
  • The purpose of this paper is to exhibit existing replacement models and to develop new replacement models for managing equipments in large organizations, private or public. Some of the models in this paper are well known and in use, and some are not. All these models are classified, depending on main factors which play key roles on the models. One group is the models in which the economic factor plays a key role, and the other is those in which both the economic factor and the effectiveness factor play key roles.

  • PDF

Mathatical Analysis for Efficiency of Power Factor Correction System Using IP3003 (역률 보상 반도체 IP3003을 이용한 역률 보상기의 효율 분석)

  • Joo, Sung-Jun;Lee, Young-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.15-20
    • /
    • 2007
  • In this paper we introduce the IP3003 which provides excellent Power Factor and Total Harmonic Distortion to the power system. It is developed by Interpion Semiconductor co. LTD. However, the efficiency of power factor correction system is very difficult to analyze mathematically. In this paper, we use the numerical simulation methods for analyzing PFC systems.

  • PDF

Enhanced Parallel-Branch Spiral Inductors (병렬분기 방법을 이용한 박막 나선 인덕터의 특성 향상)

  • 서동우;민봉기;강진영;백문철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.89-93
    • /
    • 2002
  • In the present paper we suggested a parallel-branch structure of aluminum spiral inductor for the use of RF integrated circuit at 1∼3 GHz. The inductor was implemented on P-type silicon wafer (5∼15 Ω-cm) under the standard CMOS process and it showed a improved quality(Q) factor by more than 10% with no degradation of inductance. The effect of the structure modification on the Q factor and the inductance was scrutinized comparing with those of the conventional spiral inductors.

  • PDF

Robust Sequential Estimation based on t-distribution with forgetting factor for time-varying speech (망각소자를 갖는 t-분포 강인 연속 추정을 이용한 음성 신호 추정에 관한 연구)

  • 이주헌
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.08a
    • /
    • pp.470-474
    • /
    • 1998
  • In this paper, to estimate the time-varying parameters of speech signal, we use the robust sequential estimator based on t-distribution and, for time-varying signal, introduce the forgetting factor. By using the RSE based on t-distribution with small degree of freedom, we can alleviate efficiently the effects of outliers to obtain the better performance of parameter estimation. Moreover, by the forgetting factor, the proposed algorithm can estimate the accurate parameters under the rapid variation of speech signal.

  • PDF