• Title/Summary/Keyword: Urine Analysis

Search Result 778, Processing Time 0.025 seconds

Effective Factors on Association between Liver/kidney Function and Blood-Cd Level in the Korean Urban People (도시거주자의 혈중 카드뮴 농도와 간 및 신장 기능과의 상관성 평가)

  • 김호현;임영욱;임종한;양지연;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.1
    • /
    • pp.33-44
    • /
    • 2003
  • The possibility that liver and kidney function is adversely affected by current levels of environmental exposure to cadmium (Cd) as investigated in adult men and women in the general population in Seoul. From February to August in 2001, blood and morning spot urine samples were collected from 136 not occupationally exposed group (age range 20∼75 years) at 4 survey sites throughout seoul. Liver and kidney function parameters in serum and urine were examined by conventional methods. The questionnaire included factors, i.e. sex, age, smoking, alcohol, diet habit etc. The geometric mean values for Cd in blood (Cd-B) were 1.43 $\mu\textrm{g}$/1, It seemed prudent to conclude that liver and kidney function as not disturbed by the current environmental exposure to Cd in study.

Diagnostic Ex-Vivo Assay of glucose Using Diabetic-Control Circuits

  • Ly, Suw-Young;Kim, Nam-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.210-217
    • /
    • 2014
  • For ex-vivo diabetic control, the voltammetric diagnosis of glucose (GU) was conducted with a modified carbon nanotube paste electrode, using handheld analytical circuits. The optimum analytical conditions were attained within the 0.5-4.0 ug/L working range and at the 0.06 ug/L detection limit, which system was interfaced to the feedback circuits and was applied to human urine for diabetic-patient diagnosis. It can be used for ex-vivo flow control analysis, vascular flow detection, and other medicinal assays.

Urinalysis and Mineral Composition of Calculus (30 Cases) (개에서의 요 결석증: 품종, 성별, 발생부위, 요 검사, 및 결석성분의 비교 (30예))

  • 정성목
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.272-275
    • /
    • 2002
  • A retrospective analysis was performed with 30 cases of canine urolithiasis presented in the period between January and December 2001 The miniature schnauzer (6 cases), maltese (5 cases) and Shih Tzu (4 cases) had higher incidences than other breeds. Canine urolithiasis occurred from one year till 12 years, but the most prevalent age was 3 years. Urinary calculi occurred more often in males (63%) than females. The most prevalent anatomic locations of calculi were urinary bladder (8 of 22 cases) and urethra (13 of 22 cases) in males and urinary bladder (10 of 18 cases) in females. The major mineral component of calculi was struvite (72%). In male dogs, out of 15 cases, 10 cases were struvite and 5 cases were calcium oxalate uroliths. And, in female dogs, 8 of 10 cases were struvite. In some cases, mineral composition and urine pH was not matched. In conclusion, in the dogs with predisposing factors for urolithiasis, regular examination or proper diet should be added to prevent the disease. And the mineral composition of calculi should not be predicted solely by the pH or crystal component of urine.

Retrospective Study of Crystalluria and Urinary Tract Symptoms in Dogs (개에서 발생한 결정뇨와 요로증후군에 대한 후향적 연구)

  • Oh, Won-Seok;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.386-391
    • /
    • 2010
  • This retrospective study was performed in 40 cases of canine crystalluria and urinary tract symptoms. Breed, age, sex, diet history and common clinical signs were investigated for patient information. CBC, serum chemistry, urinalysis, urine culture, urine sediment and urinary stone analysis were undertaken for clinicopathological diagnosis. Crystalluria and urinary tract symptoms occurred from 6 months till 14 years in this clinical investigation and the average age was 4.68 years. It had taken an average 7.4 weeks to correct crystalluria and urinary tract symptoms treated by supportive therapy and dietary management. In conclusion, regular clinical pathologic examination, treatment and diet management should be needed to prevent the formation of urolithiasis and urinary tract diseases in dogs with crystalluria and urinary tract symptoms.

Hazardous Substance Analysis of Disposable Diaper for Infant (유아용 일회용 기저귀의 유해성 평가)

  • 신정화;윤혜온;박미애;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.1
    • /
    • pp.165-171
    • /
    • 2004
  • The analytical method of toxic heavy metals in disposable diapers was developed. Disposable diapers obtained from Korea, Japan, America and German were determinated and quantified. Sample treatment (Total Digestion) was wet chemical acid digestion for extraction of nine hazardous inorganic elements (Sb, As, Pb, Cd, Cr, Co, Cu, Ni, Hg) in disposable diapers. Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) have been used for analyzing nine hazardous inorganic elements. The results were as follows : The concentration of extractable Sb which was treated for 3 hours with artificial urine and disposable diapers was higher than those of 6 hours and 24 hours. The concentration of extractable Cr was same as Sb. On the other hands, the behavior of Cu and Ni were different from Sb and Cr. Concentrations of extractable Cu and Ni increased as increasing the reaction time between artificial urine and disposable diapers.

Cross-reactivity of Amphetamine Analogues in Various Immunoassays (면역분석법에서 암페타민류의 교차 반응성)

  • 박미정;최화경;최상길;손행자;임미애;정희선
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.266-270
    • /
    • 2003
  • We evaluated four commercially available methamphetamine immunoassays for their relative cross-reactivities of amphetamine analogues in human urine: Abbott TDx, Vitalab Selectra and on-site test kits (Accusign MET, SD bioline MET). High cross-reactivities were shown at designer's drugs such as methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA) and methylenedioxyethylamphetamine (MDEA) in all of the tested immunoassays. Methoxyphenamine, fenfluramine and phentermine were positive in TDx and Selectra, but were not positive in on-site test kits. Pseudoephedrine, norpseudoephedrine, ephedrine, norephedrine, MDMA, MDA, fenfluramine and phentermine were detected by gas chromatography/mass spectrometry(GC/MS) in false positive urines. Since the overall specificity of any of the devices was not 100%, we found it is important to confirm any positive screening test result, so we developed simultaneous determination of amphetamine analogues in urines. After alkalinization of the urine samples with 6-N NaOH, the analytes were extracted using ethyl acetate, derivatized with pentafluoropropyl anhydride (PFPA) prior at GC/MS analysis.

Endovascular Closure Resolves Trimethylaminuria Caused by Congenital Portosystemic Shunts

  • Ponce-Dorrego, Mar?a Dolores;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.588-593
    • /
    • 2019
  • This study aimed to report three new cases of an association between two rare conditions, congenital portosystemic shunts (CPSS) and trimethylaminuria (TMAU), and the efficacy of endovascular closure of the CPSS for resolving TMAU. Between November 2014 and April 2017, 15 patients with CPSS were enrolled in this prospective study to assess the efficacy of percutaneous endovascular shunt closure. Three patients presented with clinical symptoms of TMAU that were confirmed by urine analysis of trimethylamine (TMA) and TMA n-oxide. One year after endovascular closure of the congenital portosystemic shunt, the same parameters were evaluated were obtained and the values were compared to the pretreatment values. The results indicated the disappearance of clinical symptoms of TMAU and normalization of the urine test parameters in two patients and no changes in one patient, who developed new portosystemic communications.

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.

Diagnostic ex vivo assay of glucose in live cell using voltammetry

  • Ly, Suw Young;Leea, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1379-1385
    • /
    • 2018
  • The hand held voltammetry systems searched diabetic assay using glucose sensor of fluorine nafion doped carbon nanotube electrode (FCNE). An inexpensive graphite carbon pencil was used as an Ag/AgCl reference and Pt counter electrode. Upon combining and using three electrode systems, optimum square wave (SW) stripping results were attained to 1.0-9.0 ug/L with 8 points. Statistic RSD precision was of 6.02 % with n=15 in 0.1 mg/L glucose. After a total of 200 second accumulation times, analytical detection limit of 0.8 ug/L was obtained. This developed technique was applied to urine samples from diabetic patients urine for fluid analysis, it was determined that the sensor can be used with a diagnostics in the ex vivo of live cells and non treated biological fluid.

Chiral separation of amino acids in urine specimens from patients with inherited metabolic disorders by achiral gas chromatography

  • Paik, Man-Jeoneg;Choi, Young-Mie;Nguyen, Duc-Toan;Kim, Ji-Yung;Kim, Jung-Han;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.218.2-218.2
    • /
    • 2003
  • An efficient method is described for the enantioseparation of urinary amino acids to determine their absolute configurations. It involves two-phase extractive ethoxycarbonylation in alkaline aqueous solution with subsequent extraction after acidification. The resulting derivatives of amino acids are converted to volatile diastereomeric esters or amides for the direct analysis by gas chromatography (GC) on achiral dual-columns with different polarities. The present method was applied to urine specimens from patients with inherited metabolic disorders. In this study, the usefulness for the chiral separation of diagnostic amino acids will be discussed.

  • PDF