• 제목/요약/키워드: Urine$

검색결과 2,999건 처리시간 0.025초

Validity of bag urine culture for predicting urinary tract infections in febrile infants: a paired comparison of urine collection methods

  • Kim, Geun-A;Koo, Ja-Wook
    • Clinical and Experimental Pediatrics
    • /
    • 제58권5호
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: Catheter urine (CATH-U) and suprapubic aspiration (SPA) are reliable urine collection methods for confirming urinary tract infections (UTI) in infants. However, noninvasive and easily accessible collecting bag urine (CBU) is widely used, despite its high contamination rate. This study investigated the validity of CBU cultures for diagnosing UTIs, using CATH-U culture results as the gold standard. Methods: We retrospectively analyzed 210 infants, 2- to 24-month-old, who presented to a tertiary care hospital's pediatrics department between September 2008 and August 2013. We reviewed the results of CBU and CATH-U cultures from the same infants. Results: CBU results, relative to CATH-U culture results (${\geq}10^4$ colony-forming units [CFU]/mL) were widely variable, ranging from no growth to ${\geq}10^5CFU/mL$. A CBU cutoff value of ${\geq}10^5CFU/mL$ resulted in false-positive and false-negative rates of 18% and 24%, respectively. The probability of a UTI increased when the CBU bacterial count was ${\geq}10^5/mL$ for all infants, both uncircumcised male infants and female infants (likelihood ratios [LRs], 4.16, 4.11, and 4.11, respectively). UTIs could not be excluded for female infants with a CBU bacterial density of $10^4-10^5$ (LR, 1.40). The LRs for predicting UTIs based on a positive dipstick test and a positive urinalysis were 4.19 and 3.11, respectively. Conclusion: The validity of obtaining urine sample from a sterile bag remains questionable. Inconclusive culture results from CBU should be confirmed with a more reliable method.

In Vitro Inhibitory Activity of Cow Urine and Dung to Fusarium solani f. sp. cucurbitae

  • Basak, A.B.;Lee, Min-Woong;Lee, Tae-Soo
    • Mycobiology
    • /
    • 제30권1호
    • /
    • pp.51-54
    • /
    • 2002
  • This paper deals with the study on comparative efficacy and in vitro activity of cow urine and cow dung for controlling root rot disease of cucumber caused by Fusarium solani f. sp. cucurbitae Snyder & Hansen following slide germination and mycelial growth inhibition tests. Results showed that both germination of conidia and the percentage inhibition of mycelial growth decreased or suppressed and varied greatly with respect to different hour and days of incubation and kind of bio-matters. In between two bio-matters cow urine was found more effective than that of cow dung in conidial germination. No germination of conidia was recorded after one hour of incubation in any medium whereas in cow urine germination of conidia was not also observed even after 2 hours of incubation. After 7 hours of incubation out of 200 conidia of F. solani f. sp. cucurbitae, 28 in cow urine and 64 in cow dung were germinated while in control a total germinated conidia was 185. In case of percentage inhibition of conidial germination the highest percentage(100%) was recorded in cow urine after 2 hours of incubation followed by 3 hours(96.0%), 4 hours(91.0%) and 6 hours(89.4%). During the test on inhibition of mycelial growth, the highest percentage(62.8%) was recorded in cow urine potato dextrose agar(CUPDA) medium tested after 4 days of incubation, followed by 3 days(60.5%), 5 days(56.5%) and 2 days(55.0%). In this test cow dung potato dextrose agar(CDPDA) had less efficacy in suppression of the percentage inhibition of mycelial growth.

휴대용 뇨당 측정 시스템의 개발 (Development of an Portable Urine Glucose Monitoring System)

  • 박호동;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.397-403
    • /
    • 2002
  • 뇨당 측정 시스템은 소변 속의 글루코오스 농도를 측정함으로서 당뇨 수치를 모니터링하는 비침습적인 당뇨병 자가 진단 장치이다. 본 논문에서는 기존의 침습형 혈당측정방법의 불편성과 비색계를 이용한 뇨당 검사법의 단점을 보완한 뇨당 측정시스템을 설계하였다. 뇨당 측정시스템은 뇨당 측정용 화학센서, 신호검출부, 디지털 제어 및 신호분석부, 디스플레이부 및 전원부로 구성된다. 뇨당측정용 센서로는 재현성이 뛰어나고 다루기가 간편하며 저렴한 가격으로 대량 생산할 수, 있는 일회용 뇨당측정용 전류화학센서를 개발하였다. 설계한 뇨당 측정시스템의 성능을 평가하기 위하여 사람의 소변에 임의의 농도의 글루코오스 성분을 섞은 용액에 대하여 글루코오스 성분 분석시 사용되는 표준장비와의 비교분석을 통해서 글루코오스 농도 검출에 대한 신뢰성 평가를 수행하였다. 회귀분석에 기초한 신뢰성 평가를 수행한 결과 표준오차는 2.85282로 나타났다. 또한, 화학센서를 사용해서 측정하는 시스템을 평가 시 중요한 파라미터인 S.D(Standard Deviation)는 10%로서 임상적으로 유효한 15% 범주 내에 있음을 확인하였고, C.V(Coefficient of Validation)값은 ,5%이내이므로 혈당센서의 기준으로 평가해 볼때 만족하는 결과를 보였다.

Comparison of metabolites in rumen fluid, urine, and feces of dairy cow from subacute ruminal acidosis model measured by proton nuclear magnetic resonance spectroscopy

  • Hyun Sang, Kim;Shin Ja, Lee;Jun Sik, Eom;Youyoung, Choi;Seong Uk, Jo;Jaemin, Kim;Sang Suk, Lee;Eun Tae, Kim;Sung Sill, Lee
    • Animal Bioscience
    • /
    • 제36권1호
    • /
    • pp.53-62
    • /
    • 2023
  • Objective: In this study, metabolites that changed in the rumen fluid, urine and feces of dairy cows fed different feed ratios were investigated. Methods: Eight Holstein cows were used in this study. Rumen fluid, urine, and feces were collected from the normal concentrate diet (NCD) (Italian ryegrass 80%: concentrate 20% in the total feed) and high concentrate diet (HCD) groups (20%: 80%) of dairy cows. Metabolite analysis was performed using proton nuclear magnetic resonance (NMR) identification, and statistical analysis was performed using Chenomx NMR software 8.4 and Metaboanalyst 4.0. Results: The two groups of rumen fluid and urine samples were separated, and samples from the same group were aggregated together. On the other hand, the feces samples were not separated and showed similar tendencies between the two groups. In total, 160, 177, and 188 metabolites were identified in the rumen fluid, urine, and feces, respectively. The differential metabolites with low and high concentrations were 15 and 49, 14 and 16, and 2 and 2 in the rumen fluid, urine, and feces samples, in the NCD group. Conclusion: As HCD is related to rumen microbial changes, research on different metabolites such as glucuronate, acetylsalicylate, histidine, and O-Acetylcarnitine, which are related to bacterial degradation and metabolism, will need to be carried out in future studies along with microbial analysis. In urine, the identified metabolites, such as gallate, syringate, and vanillate can provide insight into microbial, metabolic, and feed parameters that cause changes depending on the feed rate. Additionally, it is thought that they can be used as potential biomarkers for further research on subacute ruminal acidosis.

Identification of bioactive components behind the antimicrobial activity of cow urine by peptide and metabolite profiling

  • Rohit Kumar;Jai Kumar Kaushik;Ashok Kumar Mohanty;Sudarshan Kumar
    • Animal Bioscience
    • /
    • 제36권7호
    • /
    • pp.1130-1142
    • /
    • 2023
  • Objective: Cow urine possesses several bioactive properties but the responsible components behind these bioactivities are still far from identified. In our study, we tried to identify the possible components behind the antimicrobial activity of cow urine by exploring the peptidome and metabolome. Methods: We extracted peptides from the urine of Sahiwal cows belonging to three different physiological states viz heifer, lactation, and pregnant, each group consisting of 10 different animals. The peptides were extracted using the solid phase extraction technique followed by further extraction using ethyl acetate. The antimicrobial activity of the aqueous extract was evaluated against different pathogenic strains like Staphylococcus aureus, Escherichia coli, and Streptococcus agalactiae. The safety of urinary aqueous extract was evaluated by hemolysis and cytotoxicity assay on the BuMEC cell line. The urinary peptides were further fractionated using high-performance liquid chromatography (HPLC) to identify the fraction(s) containing the antimicrobial activity. The HPLC fractions and ethyl acetate extract were analyzed using nLC-MS/MS for the identification of the peptides and metabolites. Results: A total of three fractions were identified with antimicrobial activity, and nLC-MS/MS analysis of fractions resulted in the identification of 511 sequences. While 46 compounds were identified in the metabolite profiling of organic extract. The urinary aqueous extract showed significant activity against E. coli as compared to S. aureus and S. agalactiae and was relatively safe against mammalian cells. Conclusion: The antimicrobial activity of cow urine is a consequence of the feeding habit. The metabolites of plant origin with several bioactivities are eliminated through urine and are responsible for their antimicrobial nature. Secondly, the plethora of peptides generated from the activity of endogenous proteases on protein shed from different parts of tissues also find their way to urine. Some of these sequences possess antimicrobial activity due to their amino acid composition.

3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘 (A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images)

  • 조태식;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.

형광법(螢光法)에 의(依)한 Rat 분뇨중(糞尿中)의 Vitamin $B_1$의 정량(定量) (Determination of Thiamine in Urine and Feces of the Rats by the Fluorometric Method)

  • 이현기;이숙희
    • 한국식품영양과학회지
    • /
    • 제3권1호
    • /
    • pp.1-5
    • /
    • 1974
  • Two 3-month old Wistar Strain male rats (weights was 270g and 340g respectively) were used as samples in order to determine the daily excretion of thiamine contained in urine and feces by the thiochrome reaction. The results were as follows. 1. Daily excretion of urine was 5,2 cc per 100 grams of body weight and that of thiamine was $18.65\;{\gamma}$ per 100 grams of plasma. 2. Daily excretion of feces was 2.4 grams per 100 grams of body weight and that of thiamine was $7.24\;{\gamma}$ per 100 grams of plasma. 3. Daily excretion of thiamine contained in urine is about twice the amount of thiamine excretion contained in feces. Thus, it can be concluded that more of the excretion of thiamine was mainly excreted through urine.

  • PDF

Comparison of Fluoride Concentrations in Urine of Korean Children Aged 3-6 Years between Living in Water-Fluoridation Area and in Non-Fluoridation Area

  • Kho, Young-Lim;Bae, Soo-Myung;Kim, Hee-Kyoung;Jung, Se-Hwan
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.286-288
    • /
    • 2005
  • This study was conducted to compare the fluoride concentrations in urine of preschool children aged 3${\sim}$6 years between residing in community water fluoridation area(Kwangju City) and non-fluoridation area(Sungnam City). The acid-diffusible fluoride in the urine and drinking water was isolated by the acid-diffusion technique and measured with a fluoride electrode. The mean daily fluoride excretion to urine of children residing in Kwangju and Sungnam were $1.27{\pm}0.75mgF^-$/g creatinine and $0.87{\pm}47 mgF^-$/g creatinine, respectively. It is concluded from this investigation that the $F^-$concentration in urine sample of kindergarten and drinking water of children living in Kwanju(fluoridated areas) were significantly higher than that of children living in Sungnam(non-fluoridated areas).

  • PDF

소변검사의 검체 채취 방법에 관한 임상실험연구 (A Clinical Trial on the Method of Urine Sampling for Urinalysis)

  • 안혜성;이성은;박현옥
    • 기본간호학회지
    • /
    • 제2권2호
    • /
    • pp.131-137
    • /
    • 1995
  • Improving validity and reliability is the important components of clinical laboratory tests. And the quality control of the test should be started with the accurate collection of specimen. Urinalysis is one of the useful and common tests in diseases diagnosis and determining the process of medical treatment. Since urinalysis is requested routinely in hospital setting, the importance of the quality control for urine specimen is often ignored. To improve the validity of urinalysis, a clinical trial was done on the method of collecting urine specimen. The result was as follows : 1. The rate of presumtive UTI(urinary tract infection) was decreased in 21.6% with experiment method for collecting urine specimen. 2. The rate of presumtive UTI in female patients was decreased in 43.2% with the experiment method. 3. The rate of negative urine culture was decreased in 6.6% with the experiment method.

  • PDF

카드뮴중독자 검색을 위한 메탈로치오네인 분석 -동물실험을 중심으로- (The analysis of metallothionein of acute cadmium poisoning - animal study -)

  • 안령미
    • 한국환경보건학회지
    • /
    • 제27권4호
    • /
    • pp.115-122
    • /
    • 2001
  • The purpose of this study was to investigate the metallothionein of acute cadmium poisoning mice as a Cadmium index. Forty male ICR mice were injected with cadmium chloride solution from 1/8LD50 to 1/2LD50 dose. At 24 hours after exposed Cd, I examined Cd and metallothionein (MT) intissues(liver and kidney) and fluids(whole blood and urine) and also measured low molecular proteins, N-acetyl-D-glucosaminidase(NAG) and 2- microglobuline (2-MG) in urine. The concentration of Cd and MT of liver kidney whole blood and urine were increased with dose dependent manner. Urinary Cd and urinary MT and very good significance (p<0.01) and urinary MT had good significance with kidney Cd and NAG but not 2-MG Conclusionally MT in urine was very correlated with kidney Cd and urine Cd, So MT maybe useful as a Cd poisoning index.

  • PDF