• Title/Summary/Keyword: Urban drainage

Search Result 362, Processing Time 0.032 seconds

Flooding Risk Assessment Using Flooding Characteristic Values (침수특성치를 이용한 침수위험성 평가)

  • Ahn, Jeonghwan;Kim, Kunwoo;Cho, Woncheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.957-964
    • /
    • 2013
  • This research is on the methodology of flood risk assessment using flooding characteristic values. Necessity of design magnitude for flood control considering floods was judged by plotting peak flow with respect to frequency and duration, and flooding magnitude was defined with 6 flooding characteristic values which were proposed to be significant factors when assessing flooding magnitude. Precipitation data used in the assessment modeling were applied by combining all the possible precipitation events. After overlapping the simulated results with precipitation matrix by flooding characteristic values, contour map was drawn, and Flooding characteristic contour graph for possible rainfall events were suggested in respect of all possible precipitation. Flooding characteristic contour graph for possible rainfall events was confirmed that reducing of damage magnitude of each flood characteristic value was figured out easily. The flood risk assessment methods suggested in this study would be a good reference for urban drainage system design, which only focuses on pipe conduit.

Flood Damage Assessment According to the Scenarios Coupled with GIS Data (GIS 자료와 연계한 시나리오별 홍수피해액 분석)

  • Lee, Geun-Sang;Park, Jin-Hyeg
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.71-80
    • /
    • 2011
  • A simple and an improved methods for the assessment of flood damage were used in previous studies, and the Multi-Dimensional Flood Damage Assessment (MD-FDA) has been applied since 2004 in Korea. This study evaluated flood damage of dam downstream using considering MD-FDA method based on GIS data. Firstly, flood water level with FLDWAV (Flood Wave routing) model was input into cross section layer based on enforcement drainage algorithm, water depth grid data were created through spatial calculation with DEM data. The value of asset of building and agricultural land according to local government was evaluated using building layer from digital map and agricultural land map from landcover map. Also, itemized flood damage was calculated by unit price to building shape, evaluated value of housewares to urban type, unit cost to crop, tangible and inventory asset of company connected with building, agricultural land, flooding depth layer. Flood damage in rainfall frequency of 200 year showed 1.19, 1.30 and 1.96 times to flood damage in rainfall frequency of 100 year, 50 year and 10 year respectively by flood damage analysis.

The Relationships of Green Euglenoids to Environmental Variables in Jeonjucheon, Korea (전주천의 녹색 유글레나조류와 환경요인과의 상호관계)

  • Kim, Jun-Tae;Boo, Sung-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.2 s.94
    • /
    • pp.81-89
    • /
    • 2001
  • In order to know relationships between green euglenoids and environmental factors, the species composition and density were assessed for 12 months together with environmental variables in the Jeonjucheon urban drainage, Korea. Nitrate was a high of 3.22 mg/1 in June and phosphate concentration was over 0.71 mg/l in the winter. The euglenoids totaled 5 genera and 71 species throughout the year, increasing in the early summer (35 to 42 texa) and decreasing in the winter (below 20 taxa). The number of green euglenoids positively correlated with surface water temperature. the total density of the green euglenoids showed a typical bimodal pattern, being maximal in the winter (5,394 cells/ml in June). The winter peak was a result of active growths of Euglena caudata, E. geniculata and E. viridis, however, each of which positively correlated with the phosphate. The early summer peak was attributed to Euglena deses, Lepocinclis ovum, and Phacus trypanon, each of which positively correlated with the ammonium and nitrate. The complete bimodal spectrum of species number and density of green euglenoids provides a sensitive image in detecting the changes of environmental variables in polluted waters such as Jeonjucheon.

  • PDF

Development of a Decision Making Model for Efficient Rehabilitation of Sewer System (효율적인 하수관거 개량을 위한 의사결정모형의 개발)

  • Lee, Jung-Ho;Jun, Hwan-Don;Joo, Jin-Gul;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.127-135
    • /
    • 2008
  • The objective of sewer rehabilitation is to improve its function while eliminating inflow/infiltration (I/I) and insufficient carrying capacity (ICC). Such rehabilitation efforts, however, have not been particularly successful due to a lack of sewer data and unsystematic field practices. The present study aimed to solve these problems by developing a decision making model consisting of two models: the rehabilitation weighting model (RWM) and the rehabilitation priority model (RPM). In RWM, the I/I of each pipe in a drainage district is estimated according to various defects, with each defect given an individual weighting factor using an analytic hierarchy process (AHP). RPM determines the optimal rehabilitation priority (ORP) using a genetic algorithm (GA). The developed models can be used to overcome the problems associated with unsystematic practices and, in practice, as a decision making tool for urban sewer system rehabilitation.

Development of Flood Inundation Analysis System for Urban Areas using GIS (GIS를 이용한 도시유역 홍수침수 분석시스템 구축)

  • 최성열;이재영;조원철;이재호;최철관
    • Spatial Information Research
    • /
    • v.11 no.2
    • /
    • pp.155-170
    • /
    • 2003
  • Flood inundation analysis system using GIS has been developed to simulate inundation in airport drainage areas. The model developed in this study has been synthetically presented and constructed the preprocess for database construction and input data preparing through a graphic user interface, GUI system and the postprocess processing graphically output resulted in mainprocess analysis model linked GIS(ArcView/Avenue). The mainprocess analysis model was simulated in real phenomenon caused by inflow of storm sewer system by simulation flooding due to backwater effect and surcharged flow in storm sewer system by simulating interaction coupling the overland flow analysis model and storm sewer system analysis model. In the future, the flood inundation analysis system developed in this study will be a great contribution to systematic decision-making for establishing the flood-mitigation management and facilities improvement plan to flooding damage in airport.

  • PDF

Drying Stream and Hydrological Environment for Gwangjucheon (광주천의 건천화와 수문환경문제)

  • Yang, Hea-Kun
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.3
    • /
    • pp.568-578
    • /
    • 2004
  • This study is aimed at investigating floodgate characteristics and environmental issues in Gwangjucheon and examining possible problems of expanding river maintenance water being carried on in the context of river recovery works. In general, the obtained results show the following. The treatment water provisioned in the restoration project of the drying stream going through the water circulation device can pollute the land and groundwater in the Gwangjucheon Basin. Besides, although about $17,565m^3$/day of water is available in the upper ground, most of it go to the junction and exhausting directly to the waste water treatment or going into the groundwater. Because of the drying stream, the amount of water going to the ground is increased. Therefore, efficient land use along with regulations to protect cultivated land and ensure recovery works of city stream through the recovery of water circulation by constructing and expanding a special drainage system are of vital importance.

  • PDF

Impact of assessment of climate variability on urban drainage system (기후변동성이 도시배수체계에 미치는 영향분석)

  • Kim, Byung-Sik;Kang, Na-Rae;Kim, Yong-Seon;Kim, Hung-Soo;Seo, Byung-Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.867-867
    • /
    • 2012
  • 기후변화와 변동으로 인해 기온, 강수, 증발산 등의 수문순환 요소들이 과거와는 다르게 빠른 속도로 변하고 있다. 이에 따라 지난 수십 년간 기후변화가 수문학적 극한사상에 미치는 잠재적 영향은 수자원공학 관련 분야에서 관심 대상이 되어왔으며, 많은 선행 연구들은 극한 수문사상의 규모 및 빈도가 증가한다는 결과를 보여 주었다. 우리나라의 경우 최근 10년간(1999~2008년) 1일 100mm 이상 집중호우의 발생빈도는 총 385회로, 70~80년대 222회에 비해 무려 1.7배나 증가했다. 2011년의 경우 7월초부터 8월 중순까지 지속적인 장마와 집중호우로 인해 1285.3mm의 누적강수량이 발생하였으며, 서울 및 수도권 지역에서 100년 빈도 설계강수량을 초과하는 집중호우 발생으로 서울의 도심지역 곳곳이 침수되어 많은 재산피해와 인명피해를 입혔다. A1B 기후변화 시나리오에 따르면 21세기말(2071~2100년)에는 20세기말(1971~2000년)에 비해 약 17%가 증가할 것으로 전망하고 있다. 이처럼 기후변화는 특히 도시수공시설물을 설계하는데 있어 가장 중요한 변수인 극한강우사상을 변화시키기 때문에 도시배수시설물을 계획하고 설계하는 수공기술자들에게 기후변화를 고려하는 일은 자명한 일이다. 또한, 기후변화로 인한 수문과정의 점진적 변화 영향은 도시배수관련 기반시설물의 첨두홍수량과 빈도를 변화시킬 것으로 예상하고 있다. 이에 본 연구에서는 기후변동이 도시배수체계에 미치는 영향을 평가하기 위해 외부기상인자의 변동을 반영할 수 있는 비정상성 빈도해석기법을 이용하여 지속시간 1기간, 3시간, 24시간 빈도별 설계강수량을 산정한 후 도시유출모형인 XP-SWMM 모형을 통해 도시배수체계에 미치는 영향을 평가하였다. 이를 통해 현재의 도시배수체계와 비교함으로써 기후변동이 도시배수체계에 미치는 영향을 정량화하였다.

  • PDF

A STUDY ON THE VARIATION OF DESIGN FLOOD DUE TO CLIMATE CHANGE IN THE URBAN CATCHMENT : A CASE STUDY ON THE HYOJA DRAINAGE BASIN IN SEOUL (기후변화에 따른 도시유역의 확률홍수량 변화에 관한 연구 : 서울시 효자배수분구를 대상으로)

  • Hwang, Jeongyoon;Kim, Hosoung;Ahn, Jeonghwan;Ahn, Hyunjun;Jeong, Changsam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.183-183
    • /
    • 2018
  • 최근 국지성 호우와 홍수, 그리고 극심한 가뭄과 같은 기후변화로 인한 극치수문현상이 빈번하게 관측되고 있다. 이는 과거와는 다른 양상의 강우사상으로 광화문(2010), 강남역(2010), 청계천(2010), 청주(2017), 부산(2017) 등 주요 도심지역에 내수침수로 인한 막대한 인명, 재산 피해를 발생시켰으며, 피해의 빈도와 강도가 증가되고 있는 추세이다. 특히 기후변화에 따른 강우강도의 증가는 설계홍수량의 변화를 초래하며, 그로 인해 홍수 위험도 증가와 치수안전도 감소 등 수공구조물의 설계기준에 불확실성을 증가시키는 원인이 되고 있다. 최근 국내에서도 기후변화에 따른 수공시설물 설계빈도 상향에 대한 필요성이 대두되고 있으나 기후변화의 불확실성 및 기후시나리오의 한계로 인해 정량적 분석결과가 제시되지 않아 정책 수립에 반영하기 현실적으로 어려운 상황이다. 본 연구에서는 기후변화에 따른 홍수특성에 대한 도시유역의 영향을 평가하기 위하여 서울 효자배수분구를 대상유역으로 선정하고, 과거관측자료 기준 S0 대비 상세화 기법(Downscaling) 및 편의보정(Bias Correlation)으로 생성된 RCP 4.5 기후시나리오 HadGEM3-RA(RCM)모델을 통해 생산된 S1, S2, S3 기간의 확률강우량의 변화를 평가하였다. 이때 확률분포형은 Gumbel, 매개변수 추정은 최우도법(ML)을 사용하였고, 도시유출모형을 이용하여 최대첨두홍수량 및 침수면적 산정하고 기후변화 기간별 변동성을 분석하였다. 평가 결과 대부분의 도시배수시설물의 설계빈도인 10년빈도를 3사분위값을 기준으로 할 때 50년과 70년 이상의 미래를 가정할 경우 각각 약 10%, 20%의 확률 홍수량이 증가가 예상되었다. 이러한 결과 현재 구축되어 있는 배수시스템의 설계빈도를 크게 상회하는 값으로 도시배수시스템에 많은 어려움을 줄 것으로 예상되며, 정량적 평가 결과가 기후변화 적응 대책 신규 시설물 설계시 참고할 수 있는 기초자료로 활용될 것으로 판단된다.

  • PDF

Development and Estimation of Double-Drainage System in Urban Areas against Localized High-Intensity Rainfall (집중호우에 대비한 도시지역 이중배수 시스템 개발 및 평가)

  • Kim, Tae Beom;Kim, Yong In;Kim, Yong In;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.362-366
    • /
    • 2015
  • 지난 백여 년 동안 인간은 과거의 그 어떤 선조들도 이루지 못한 지식과 기술의 발전을 통해 고도로 산업화된 사회를 이루었지만, 전 지구적으로 기후변화라는 부차적인 결과와 현실에 직면하고 있다. 이상기후 현상은 전지구 규모뿐만 아니라 일정한 소규모 지역에서도 관측되고 있으며, 국내에서는 특히 특정 지역에 국한되어 단시간에 발생하는 집중호우가 대표적인 사례이다. 현재까지 집중호우 발생 지역과 정도를 예측하기란 불가능한 상태이며, 산업화와 도시화가 진행될수록 그 피해는 더욱 증가할 것으로 예상된다. 따라서 집중호우에 대비한 도시 배수 시스템을 재점검할 필요가 있으며, 기존의 배수시설을 대체할 만큼 효율적인 배수구조물의 개발이 시급하다. 기존 도시지역의 측구형 수로관에는 마감불량, 정밀시공의 어려움, 이물질의 누적과 물고임, 노출로 인한 파손, 포장층 침투수 배수문제 등 많은 문제점들이 존재한다. 따라서 본 연구에서는 기존의 측구형 수로관의 단점을 보완하는 더욱 효율적인 집수정을 개발하고자 하였다. 집수정을 덮고 있는 포장층 상부면을 따라 흐르는 표면수를 처리할 뿐만 아니라, 포장층 내부로 스며드는 침투수를 처리 가능하도록 구조체 상부에 침투수 유입공을 설치하여, 표면수와 침투수를 동시에 고려하는 이중배수 시스템을 구성하였다. 본 연구에서 개발하는 집수정 구조체는 침투수에 의한 도로 및 구조체의 내구성 감소 및 겨울철 동파 현상을 방지할 수 있을 뿐 아니라, 단순공정, 시공성 향상, 유지비용절감 등 기존 배수 시스템과 비교해 많은 장점을 내포하고 있다. 본 연구에서 개발하는 이중배수 집수정의 효율 및 배수능력 평가를 위해서는 기존의 구조체와 차별되는 침투수 유입공에 대한 평가가 선행되어야 한다. 이를 위해서 침투수 유입공에 대한 실내 실험 장치를 구축하였으며, 반복 실험을 통해 침투수 유입공을 통한 배출 능력을 평가하고자 하였다. 또한 실험 결과를 바탕으로 구조체의 효능을 결정짓는 기준을 제시하고자 한다.

  • PDF

Study on the discharge of soil particles and ground collapse through cracks in underground structures (지중구조물 균열을 통한 토립자 유출 및 지반함몰 특성 연구)

  • Kim, Ho-Jong;Kim, Kang-Hyun;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.699-715
    • /
    • 2019
  • Recently, in urban areas, cavities and ground collapse adjacent to underground structures are frequently reported. Several studies on the cavity generation by structure cracks have been made, however they are focused on the cause of cracks and settlement of the ground. In this paper, soil particle and groundwater discharge through pipe cracks and cavity generation mechanism are investigated. The theoretical analysis of the groundwater, which is the main factor of the drainage of the soil particles, and the particle transport mechanism and flow characteristics were investigated. An experimental model test was carried out to identify the mechanism of cavity generation by underground buried pipe cracks. The soil particle weight of discharge through the cracks, and the movement characteristics of the particles were analyzed using PIV. In this study, it is clearly identified that soil particle movements, cavity generation and ground collapse that occur in the ground are basically caused by the movement of groundwater.