• Title/Summary/Keyword: Urban air temperature

Search Result 350, Processing Time 0.022 seconds

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

Establishing non-linear convective heat transfer coefficient

  • Cuculic, Marijana;Malic, Neira Toric;Kozar, Ivica;Tibljas, Aleksandra Deluka
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.107-119
    • /
    • 2022
  • The aim of the work presented in this paper is development of numerical model for prediction of temperature distribution in pavement according to the measured meteorological parameters, with introduction of non-linear heat transfer coefficient which is a function of temerature difference between the air and the pavement. Developed model calculates heat radiated from the pavement back in the air, which is an important part of the heat trasfer process in the open air surfaces. Temperature of the pavement surface, heat radiation together with many meteorological parameters were measured in series during two years in order to validate the model and calibrate model parameters. Special finite element method for temperature heat transfer towards the soil together with the time integration scheme are used to solve the governing equation. It is proved that non-linear heat transfer coefficient, which is a function of time and temperature difference between the air and the pavement, is required to decribe this phenomena. Proposed model includes heat tranfer coefficient callibration for specific climate region, through the iterative inverse procedure.

Development of a High-Resolution Near-Surface Air Temperature Downscale Model (고해상도 지상 기온 상세화 모델 개발)

  • Lee, Doo-Il;Lee, Sang-Hyun;Jeong, Hyeong-Se;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.31 no.5
    • /
    • pp.473-488
    • /
    • 2021
  • A new physical/statistical diagnostic downscale model has been developed for use to improve near-surface air temperature forecasts. The model includes a series of physical and statistical correction methods that account for un-resolved topographic and land-use effects as well as statistical bias errors in a low-resolution atmospheric model. Operational temperature forecasts of the Local Data Assimilation and Prediction System (LDAPS) were downscaled at 100 m resolution for three months, which were used to validate the model's physical and statistical correction methods and to compare its performance with the forecasts of the Korea Meteorological Administration Post-processing (KMAP) system. The validation results showed positive impacts of the un-resolved topographic and urban effects (topographic height correction, valley cold air pool effect, mountain internal boundary layer formation effect, urban land-use effect) in complex terrain areas. In addition, the statistical bias correction of the LDAPS model were efficient in reducing forecast errors of the near-surface temperatures. The new high-resolution downscale model showed better agreement against Korean 584 meteorological monitoring stations than the KMAP, supporting the importance of the new physical and statistical correction methods. The new physical/statistical diagnostic downscale model can be a useful tool in improving near-surface temperature forecasts and diagnostics over complex terrain areas.

Exploring Physical Environments, Demographic and Socioeconomic Characteristics of Urban Heat Island Effect Areas in Seoul, Korea (서울시 도시열섬현상 지역의 물리적 환경과 인구 및 사회경제적 특성 탐색)

  • Cho, Hyemin;Ha, Jaehyun;Lee, Sugie
    • Journal of the Korean Regional Science Association
    • /
    • v.35 no.4
    • /
    • pp.61-73
    • /
    • 2019
  • Urban development and densification have led to the Urban Heat Island Effect, in which the temperature of urban space is higher than the surrounding areas, and the intensity is increasing with climate change. In addition, when the city's air temperature rises in summer, low-income, elderly population, and socially vulnerable people who have health problems lack the ability to cope with the elevated heat environment. Therefore, this study aimed to identify the urban heat island area of Seoul through Hotspot analysis, which is a spatial statistics technique, and explored physical environments, demographic and socioeconomic characteristics of urban heat island effect areas using logistic regression models. This study performed urban heat island hotspot analysis using the average air temperatures of the 423 administrative dongs in Seoul. Analysis results identified that the urban heat islands were concentrated in Jung-gu, Jongno-gu, Yongsan-gu, and Yeongdeungpo-gu. Logistic regression analysis results indicated that urban heat island areas of Seoul were affected by residential floor area ratio, commercial facility floor area ratio, overall floor area ratio, impervious surface ratio, and normalized difference vegetation index(NDVI). In addition, as a result of analyzing the vulnerable area of thermal environment considering the demographic and socioeconomic characteristics of the heat island area, urban heat island areas of Seoul were significantly associated with the proportion of low-income elderly living alone. The result of this study provided useful insights for urban thermal environmental design and policy development that could improve the thermal environment for the socially disadvantaged urban population.

Performance Evaluation of a Cylindrical Steam Reformer with Various Thermal Conditions (원통형 수증기 개질기의 열적조건 변화에 따른 개질성능 평가)

  • Han, Hun Sik;Kim, Seo Young;Karng, Sarng Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.269-274
    • /
    • 2014
  • The experimental performance evaluation of a cylindrical steam reformer with various thermal conditions has been conducted. The bottom space of the cylindrical reactor was packed with Ruthenium (Ru) catalyst. A three-segment furnace was installed to create the axially variable boundary temperature distribution. Six K-type thermocouples were inserted into the catalyst layer, and three exhaust ports were fabricated on the side wall along the flow direction. The exhausted gases at each port were analyzed by using gas chromatograph (GC) system. The experimental results showed that the reforming reaction occurs intensively in the upstream region and more hydrogen is obtained when the intake gas is sufficiently heated up through the enhanced steam reforming (SR) reaction. The axially increasing boundary temperature setup provided the maximally accumulated reforming efficiency of 74.8%, when the reactor was placed at the 3rd section of the furnace.

A Study on Microclimate Change Via Time Series Analysis of Satellite Images -Centered on Dalseo District, Daegu City- (위성영상의 시계열 분석을 통한 미기후변화 분석 -대구시 달서구를 대상으로-)

  • Baek, Sang-Hun;Jung, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.34-43
    • /
    • 2009
  • Based on previous research on ways of reducing an urban heat island phenomenon via an introduction of wind corridors, I conducted this study to see what influence a change in land cover arising of or going through urbanization has on wind corridors of urban space. As a target place, I chose Daegu city where is a representative extreme heat place in Korea and has been also largely expanded in size by incorporating its neighboring areas since the 1980s, expecially Dalseo District whose surface temperature gap is large. The population of Dalseo District has been sharply increased since its creation as a new administrative district in 1988. I studied on the urban microclimate change for a 20-year period by using satellite images on summer months in 1987, 1997 and 2007 in time frames. The finding of this study found that a reduction of natural land cover and an increase of artificial land cover serves as a disadvantageous factor for cold air creation and flowing and strikingly lowers the amount and height of cold air in the downtown area. It seemed that the cold air creation and flowing functions are influenced by land cover. In order to steadily create cold air and secure its flowing, it is thought that urban development or urban regeneration should be implemented by analysing the characteristics of the space surrounding the city. By doing so, a pleasant and healthy city could be formed.

  • PDF

Effects of Land Use Pattern on Urban Heat Island in Chungju City (토지이용형태가 도시열섬현상에 미치는 영향 - 충주시를 사례로 -)

  • Yoon, Yong-Han;Bae, Byung-Ho;Kim, Won-Tae;Park, Bong-Ju;Cho, Sung-Moh;Cho, Hyun-Soo
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1063-1069
    • /
    • 2007
  • The present study investigated the causes and intensity of the urban heat island phenomenon by the seasons according to the pattern of land use in Chungju City. Highest temperature and lowest moisture areas of the urban were very similar to the distribution of commercial districts, on the other hand, lowest temperature and highest moisture areas were distributed in manufacturing districts, green zones and the Hoam Lake. If appear at intensity of the distance from the outer circumference of commercial districts, wind direction and the rise of temperature, we could observe the remarkable expansion of high temperature from commercial districts toward residential districts around of downwind in all seasons. In case the effect of the wind was not significant as well, high temperature in commercial districts appeared tendency that a little spread to 1, 2 residential districts around. But checked up the intimate relations between the amount of moving heat and wind, when out of consideration that size of area was not much compared than residential areas of downwind affected by the wind. These phenomenon was relatively obvious in summer, the other side, in spring and autumn appeared a similar tendency.

Spatial Distribution of Urban Heat Island based on Local Climate Zone of Automatic Weather Station in Seoul Metropolitan Area (자동기상관측소의 국지기후대에 근거한 서울 도시 열섬의 공간 분포)

  • Hong, Je-Woo;Hong, Jinkyu;Lee, Seong-Eun;Lee, Jaewon
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.413-424
    • /
    • 2013
  • Urban Heat Island (UHI) intensity is one of vital parameters in studying urban boundary layer meteorology as well as urban planning. Because the UHI intensity is defined as air temperature difference between urban and rural sites, an objective sites selection criterion is necessary for proper quantification of the spatial variations of the UHI intensity. This study quantified the UHI intensity and its spatial pattern, and then analyzed their connections with urban structure and metabolism in Seoul metropolitan area where many kinds of land use and land cover types coexist. In this study, screen-level temperature data in non-precipitation day conditions observed from 29 automatic weather stations (AWS) in Seoul were analyzed to delineate the characteristics of UHI. For quality control of the data, gap test, limit test, and step test based on guideline of World Meteorological Organization were conducted. After classifying all stations by their own local climatological properties, UHI intensity and diurnal temperature range (DTR) are calculated, and then their seasonal patterns are discussed. Maximum UHI intensity was $4.3^{\circ}C$ in autumn and minimum was $3.6^{\circ}C$ in spring. Maximum DTR appeared in autumn as $3.8^{\circ}C$, but minimum was $2.3^{\circ}C$ in summer. UHI intensity and DTR showed large variations with different local climate zones. Despite limited information on accuracy and exposure errors of the automatic weather stations, the observed data from AWS network represented theoretical UHI intensities with difference local climate zone in Seoul.

A Study on Urban Environmental Climate Mapping Method for Sustainable Urban Planning in Daegu (대구지역의 환경친화적 도시계획을 위한 도시환경기후지도 작성에 관한 연구)

  • Park, Myung-Hee;Jung, Woo-Sik;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.465-482
    • /
    • 2011
  • To preserve atmospheric environment of urban areas, it needs to create urban space considering air pollution sources and natural and geographical properties such as wind circulation. According to this study could examine climate and environmental characteristics of Daegu and accordingly suggest a climate map in urban environment and an "advice map" in urban planning. The urban area(area paved with asphalt and concrete) of Daegu has increased by more than five times since 1960. In addition, the analysis of thermal environment through satellite data shows that the surface temperature between a place paved with artificial structures and a farmland shows $10{\sim}20^{\circ}C$ difference during the daytime in the summer. Regarding the parks inhibiting the heat island of a city have the small area of trees, and the road paved with concrete is wide so that they hardly serve as the source of heat absorption. As Apsan is located to the south of Daegu and Palgonsan to the north and Daegu has east high west low type, mountain wind from mountains in the south and north passes a city and delivers heat and air pollutions at night. In the west of Daegue, there is the poorest environment and industrial facilities and environmental basic facilities are mostly located, so large residential complexes that are being built around the industrial facilities as if they set up a folding screen and therefore the poor environment is increasingly worse.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.