• Title/Summary/Keyword: Urban Higher Temperature

Search Result 232, Processing Time 0.028 seconds

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

Theoretical Analysis of a Rotary Heat Exchanger Based on a Simplified Model (단순모델에 의한 회전형 열교환기 이론해석)

  • Son, Sung Gyun;Kim, Yongchan;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.409-417
    • /
    • 2015
  • A simplified rotary heat-exchanger model was developed with an assumption of a linear temperature distribution along the flow direction. Based on the model, the exact fluid solution and solid temperature variations were obtained and verified from a comparison with previous numerical studies. The heat transfer in the rotary heat exchanger was investigated using the theoretical solutions. The heat exchanger's effectiveness was shown to be saturated, with a rotational-speed increase that is higher than a critical value that is solely dependent on the thermal capacity of the solid matrix but independent of the fluid flow rate; the saturated value of the effectiveness was determined only by the NTU of the heat exchanger. Where the thermal diffusivity of the solid matrix is so slight that the thermal penetration depth becomes smaller than the matrix thickness, the effective thermal capacity of the solid matrix decreased according to the penetration depth.

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Analysis of basic IAQ management factors in metropolitan subway (수도권 지하철 내부의 IAQ 관리 기초 인자 분석)

  • Cho Young-Min;Park Duckshin;Lee Cheulgyu;Park Byunghyun;Park Eunyoung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1138-1142
    • /
    • 2005
  • The IAQ management in subway cabin is very important for the enhancement of the amenity and health of passengers because the subway carries many passengers in a relatively short time mostly in urban area. However, since the ventilation of most subway cabins are performed by simple opening of doors at each stations, the IAQ management is not easy. In this study, we measured some IAQ factors (temperature, relative humidity, particulate matters, CO, and $CO_2$ concentration) of subway cabin in Seoul area. The results showed that the IAQ of the cabin was relatively acceptable. However, $CO_2$ concentrations were higher than 1,000 ppm in most cases. $CO_2$ concentration was mostly proportional to the number of passengers in cabin. Therefore, new method to relieve the $CO_2$ concentration is urgently required.

  • PDF

Concentration and Size Distribution of Atmospheric Particulate Matters, Chloride, Nitrate, and Sulfate Salts in Urban Air (都市大氣중 浮遊粒子狀物質, 鹽化物, 窒酸鹽 및 黃酸鹽의 濃度와 粒經分布)

  • Sohn, Dong-Hun;Heo, Moon-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1986
  • Atmospheric particulate matter (A. P. M.) was collected and size-fractionated by an Andersen high-volume air sampler over 15 month period from Jan. 1985 to Feb. 1986 in Seoul. The concentration of chloride, nitrate and sulfate were extracted in an ultrasonic bath and were analyzed by ion chromatography. The annual arithmetical mean of A. P. M. was 128.54 $\mug/m^3$. The concentration of anions were 2.88 $\mug/m^3$ for chloride, 3.86$\mug/m^3$ for nitrate, and 25.44$\mug/m^3$ for sulfate. The content of A. P. M. was lowest in the particle size range 1.1 $\sim 3.3\mum$ and increased as the particle size increased or decreased. And the anions exhibited a seasonal variation in the isize distribution. The contents of anions were higher in winter than summer. Ther ratio of fine particles to the total particles defined by F/T for chloride, nitrate and sulfate. The F\ulcornerT of these anion generally decrease with increasing air temperature. This tendency was prevalent in the chloride and nitrate.

  • PDF

Preliminary Report of Observed Urban - Rural Gradient of Carbon Dioxide Concentration across Seoul, Suwon, and Icheon in South Korea (도시 - 전원간 이산화탄소(CO2) 농도구배 예비관측 결과)

  • Chung, U-Ran;Lee, Kyu-Jong;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.4
    • /
    • pp.268-276
    • /
    • 2007
  • Urban atmosphere may play as a harbinger for the future climate change with respect to temperature and $CO_2$ concentration. The Seoul metropolitan area is unique in rapid urbanization and industrialization during the last several decades, providing a natural $CO_2$ dome with increased temperature. This study was carried out to evaluate the feasibility of using the urban-rural environmental gradient in replacement of the IPCC mid-term scenario (after 30-50 years). For this, we measured atmospheric $CO_2$ concentration and air temperature at three sites with different degree of urbanization (Seoul, Suwon, and Icheon). Results from 11-month measurement can be summarized as follows: (1) The annual mean $CO_2$ concentration across 3 sites was in the order of Seoul (439 ppm) > Suwon (419 ppm) > Icheon (416 ppm), showing a substantial urban-rural environmental gradient. (2) The diurnal fluctuation in $CO_2$ concentration was greater in summer than in winter, showing the effect of photosynthesis on local $CO_2$ concentration. (3) The daily maximum $CO_2$ concentration was observed at 0500 LST in spring and summer, 0800 LST in autumn, and 0900 LST in winter, showing the sunrise-time dependence. (4) The observed hourly maximum $CO_2$ concentration averaged for the whole period was 446 ppm in Seoul at 0700 LST, while the minimum was 407 ppm in Suwon at 1500 LST. (5) Compared with the background atmospheric concentration of $CO_2$ in Anmyeon-do (377.4 ppm annual mean), $CO_2$ concentration of the study sites was higher by 14% in Seoul, by 10% in Suwon, and by 9% in Icheon. The observed $CO_2$ concentration in Seoul reached already 98% of the 2030-2040 projection (450 ppm) and 80% of the 2040-2050 projection (550 ppm) under the IPCC BAU scenario, showing a feasibility of using the $CO_2$ dome of Seoul as a natural experimental setting for the mid-term climate change impact assessment.

Environmental Planning Contermeasures Considering Spatial Distribution and Potential Factors of Particulate Matters Concentration (미세먼지 농도의 공간적 현황 및 잠재영향인자를 고려한 환경계획적 대응 방향)

  • Sung, Sun-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2020
  • Adverse impact of Particulate Matters(PM10, PM2.5; PMs) significantly affects daily lives. Major countermeasures for reducing concentration of PMs were focused on emission source without considering spatial difference of PMs concentration. Thus, this study analyzed spatial·temporal distribution of PMs with observation data as well as potential contributing factors on PMs concentration. The annual average concentration of PMs have been decreased while the particulate matter warnings and alerts were significantly increased in 2018. The average concentration of PMs in spring and winter was higher than the other seasons. Also, the spatial distribution of PMs were also showed seasonality while concentration of PMs were higher in Seoul-metropolitan areas in all seasons. Climate variables, emission source, spatial structure and potential PM sinks were selected major factors which could affects on ambient concentrations of PMs. This paper suggest that countermeasures for mitigating PM concentration should consider characteristics of area. Climatic variables(temperature, pressure, wind speed etc.) affects concentrations of PMs. The effects of spatial structure of cities(terrain, ventilation corridor) and biological sinks(green infrastructure, urban forests) on concentration of PMs should be analyzed in further studies. Also, seasonality of PMs concentration should be considered for establishing effective countermeasures to reduce ambient PMs concentration.

A Study on the Relationship between the Summertime Night Cooling Rate and Meteorological Elements in Daegu (대구의 여름철 야간 냉각량과 기상요소와의 관련성 연구)

  • Kim, Ha-Young;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.30 no.10
    • /
    • pp.821-831
    • /
    • 2021
  • The relationship between night cooling rate and meteorological elements was investigated over the past five years (2016-2020), using weather data from the new (Daegu(143)) and old (Shinam(860)) Daegu Regional Meteorological Agency located in the suburban and urban regions, respectively. There was a correlation between the total daily amount of solar radiation (Stot) and the night cooling rate in the both regions. However, a higher correlation was observed at the new Daegu Regional Meteorological Agency station (Daegu(143)). In particular, data from the new Daegu Regional Meteorological Administration's observatory, which experiences a low thermal storage effect caused by artificial structures, showed a higher correlation between nighttime cooling and weather factors. The reason for this is that the lesser the heat storage effect caused by the artificial structures, the better the effect of surface radiation cooling on temperature reduction. These findings confirm that the correlation between night cooling and weather factors can be used to assess the impact of artificial structures in cities.

Analysis for Roll Forming Process to Levitation Rail of Urban Maglev System (도시형 자기부상열차 부상레일의 롤 성형공정 해석)

  • Kim, Kyung-Taek;Kim, Jae-Yong;Kim, Yong-Hwan;Park, Jin-Soo;Pyen, Sang-Yun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.31-38
    • /
    • 2008
  • This Study discussed the roll forming process analysis of levitation rail for urban Maglev vehicle. To verify validity of roll forming process, we analyzed roll forming process for track shoe which is similar to levitation rail. The analysis process was composed of 12 passes and was performed for only 8 passes except overlapping passes. In the variation of temperature with each pass, surface temperature of the structure was cooled from initial $1200^{\circ}C$ to $1010^{\circ}C$ during 30 second before first pass, and central temperature and surface temperature was cooled to $980^{\circ}C$ and $900^{\circ}C$ in final pass, respectively. A length of structure after final pass is about 5 times longer than that before roll forming process. A strain of structure had a higher value in the inner part of the track shoe and show from minimum 2.5 to maximum 6.5. A torque applying on roll appear high in 2, 3 and 4 passes and a maximum value was $27,000ton{\cdot}mm$. Also it was analyzed that a load to the normal direction needs maximum 300ton.

  • PDF

Observational Study of Thermal Characteristics by Distribution Ratio of Green Area at Urban in Summer Season (하절기 관측을 통한 도시의 지역별 공간녹지분포율에 따른 열환경 특성 연구)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.8-16
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of thermal environment in the summer season by conducting the field observation of temperature, relative humidity, and globe temperature in some parts of the city. Observation point was divided to a densely populated area, a residential area, a green area, a waterfront green area and a suburban district by the distribution ratio of green area. In this study, the correlation between maximum temperature and globe temperature, study on index for intensity of the tropical night and the temperature distribution characteristic of measurement points by the distribution ratio of green area were analyzed. The results of this study are as follows. (1) The difference between temperature and globe temperature by the distribution ratio of green area is confirmed. The difference of nighttime is more clearly that of daytime. (2) The average temperature and globe temperature of the densely populated area($29.2^{\circ}C$, $33.7^{\circ}C$) are higher than that of the waterfront green area($27.9^{\circ}C$, $32.0^{\circ}C$) by $1.3^{\circ}C$ and $1.7^{\circ}C$, respectively. (3) The number of tropical nights has different days of tropical nights by the distribution ratio of green area of 17days for the Daegu weather station, 14days for adensely populated area, 14days for a residential area, 6days for a green area, 2days for a waterfront green area, and 2days for a suburban district. (4) The results of the slope of trend line for the effects of the temperature on globe temperature change and the intercept for the size of the impact of radiant energy gained around by the analysis of the correlation between the maximum temperature and globe temperature can be utilized objective evaluation index of the each point's artificial effects.