• 제목/요약/키워드: Upper electrode

검색결과 155건 처리시간 0.025초

평등전계에서 도전성 구형 입자의 운동 (Motion of Conductive Spherical Particle under Uniform Electric Field)

  • 임헌찬
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석 (Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique)

  • 정종식;이승재;이재복
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

대전입자형 디스플레이의 전기 및 광학특성 분석 (Electrical and Optical Analysis of Charged Particle type Display)

  • 김백현;김성운;황인성;김처주;김영조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.66-67
    • /
    • 2007
  • We have developed reflective information display using opposite-charged two particles. An appropriate amount of both the yellow and the black powers are putted between the ITO patterned glass substrate separated with cell gap. The rib maintains the cell gap and prevents the interference between the pixels. When a negative voltage is applied to the upper ITO electrode, the positively charged black powder moves to the upper electrode viewing a black appearance. In case of positive voltage is applied to this electrode white particle is observed. So we analyzed the electrical and optical properties of our charged particle type display panel.

  • PDF

각 층에 따른 염료감응형 태양전지의 특성 개선 - I (-상부전극을 중심으로) (An Improvemcent of the Characteristics of DSSC by Each Layers - I (- Upper Electrode))

  • 마재평;박치선
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.57-63
    • /
    • 2011
  • Photovoltaic effect is confirmed in DSSC fabricated under the common conditions. In upper electrodes, validity of ZnO as new TCO material was investigated and an improvement of characteristics in DSSC was tried by control of process conditions at semiconductive powder layer. ZnO thin film showed very high resistivity, therefore efficiency of solar cell was lower than that of conventional ITO-related material. DSSC characteristics was able to improve by thin blocking layer doposited between the TCO and semiconductor layer.

소오스-드레인 기생용량을 개선한 박막트랜지스터 제조공정 (The Fabrication of a-Si:H TFT Improving Parasitic Capacitance of Source-Drain)

  • 허창우
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.821-825
    • /
    • 2004
  • 본 연구는 에치스토퍼를 기존의 방식과 다르게 적용하여 수소화 된 비정질 실리콘 박막 트랜지스터의 제조공정을 단순화하고, 박막 트랜지스터의 게이트와 소오스-드레인간의 기생용량을 줄인다. 본 연구의 수소화 된 비정질 실리콘 박막 트랜지스터는 Inverted Staggered 형태로 게이트 전극이 하부에 있다. 실험 방법은 게이트전극, 절연층 , 전도층, 에치스토퍼 및 포토레지스터층을 연속 증착한다. 스토퍼층을 게이트 전극의 패턴으로 남기고, 그 위에 n+a-Si:H 층 및 NPR(Negative Photo Resister)을 형성시킨다. 상부 게이트 전극과 반대의 패턴으로 NPR층을 패터닝하여 그것을 마스크로 상부 n+a-Si:H 층을 식각하고, 남아있는 NPR층을 제거한다. 그 위에 Cr층을 증착한 후 패터닝하여 소오스-드레인 전극을 위한 Cr층을 형성시켜 박막 트랜지스터를 제조한다. 이렇게 제조하면 기존의 박막 트랜지스터에 비하여 특성은 같고, 제조공정은 줄어들며, 또한 게이트와 소오스-드레인간의 기생용량이 줄어들어 동작속도를 개선시킬 수 있다.

3전극형 반사형 디스플레이에서 패키징 방법에 의한 광특성 개선에 관한 연구 (A Study on Improvement of Optical Characteristics by Packaging Methods in Three Electrode-Type Reflective Display)

  • 박상현;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제30권3호
    • /
    • pp.170-174
    • /
    • 2017
  • In 3 electrode reflective displays using a plastic substrate, unstable packaging induces particle clumping and optical degradation due to external air inflow and electronic ink evaporation. In this work, we fabricate 3 electrode electronic paper using glass wafer, ITO/plastic film, and ITO/glass/gas barrier film as an upper substrate after injecting electronic ink onto the lower substrate. Then, we studied its properties. After operating under stress conditions for 336 hours at $85^{\circ}C$ and 75% humidity, the reflectivity of driven e-paper panels with white color was 25.5% for the panels using glass wafer, 22.5% for plastic film including a gas barrier layer, and 16% for plastic film only. From these optical properties, we conclude that gas barrier film improves upper film isolation as a desirable packaging method.

캘릭스 [4]크라운 유도체를 이온선택성 물질로 사용한 세슘이온 선택성 막전극 (Cesium Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore)

  • 남궁미옥;임혜재;백경수;윤영자
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.428-432
    • /
    • 2000
  • 새로운 캘릭스[4]크라운 화합물을 이온 선택성 물질로 사용하고 지지체로 PVC(polyvinyl chloride), 가소제로 DOS(dioctyl sebacate)를 사용하여 이온선택성 막전극을 제작 하였다. 제작한 막전극을 지시전극으로 사용하여 알칼리, 알칼리토금속 이온에 대하여 각각의 감응전위를 측정한 결과, pH7.20 Tris buffer에서 $10^{-5}-10^{-1}M$ 농도의 변화에 따른 $Cs^+$이온의 감응전위가 이론적인 Nernst식 기울기에 가까운 52.3 mV/decade로 직선성이 잘 성립하는 감응전위를 나타내었다. $Cs^+$이온 농도변화에 따른 막의 감응시간은 $t_{90%}$=10sec이었고, 막의 사용기간은 2개월 정도이다.

  • PDF

TRIODE 장치를 이용한 건식 식각 특성에 관한 연구 (A Study on the Characteristics of TRIODE Etching)

  • 신재열;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.199-202
    • /
    • 1988
  • TRIODE etching characteristics are studied. 13.56 MHz is applied to the Lower electrode and 100 KHz to the upper electrode. Wafers are etched on the lower electrode and we investigate their characteristics and compare then with those of RIE. It shows TRIODE etch rate is much higher than that of RIE but the surface is more contaminated.

  • PDF

휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발 (Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs)

  • 정연희;김승환;양영모
    • 한국의류학회지
    • /
    • 제34권1호
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.