• Title/Summary/Keyword: Unit weight test

Search Result 450, Processing Time 0.03 seconds

Analysis of the Correlation between Compaction Characteristics and Spectral Information of Reactive Materials for Absorption of Oil Contaminant (유류 오염물 흡수가 가능한 반응재료의 다짐 특성-분광정보 상관관계 분석)

  • Gigwon Hong
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.950-957
    • /
    • 2023
  • Purpose: The response technology is needed to prevent the spill of highly toxic oil contaminants in advance. Therefore, this paper described the results of an experimental study to predict the engineering properties of the developed reactive material. Method: Compaction tests and spectral information acquisition experiments were conducted on the reactive materials, and the results were evaluated. In addition, the correlation between spectral information and maximum dry unit weight was analyzed to evaluate the possibility of predicting the engineering properties for reactive materials. Result: The compaction test results showed that the maximum dry unit weight was in the range of approximately 9kN/m3 to 10kN/m3. The spectral information confirmed that the maximum reflectance decreased as the polynorbornene decreased. Conclusion: It was confirmed that the maximum dry unit weight of the reactive material for absorbing oil contaminants can be predicted using the maximum reflectance according to the component ratio of the reactive material.

Prediction of Physical Characteristics of Cement-Admixed Clay Ground (점토-시멘트 혼합 지반의 물리적 특성 예측)

  • Park, Minchul;Jeon, Jesung;Jeong, Sangguk;Lee, Song
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.529-536
    • /
    • 2014
  • Physical characteristics of cement-admixed clay such as water content, specific gravity, unit weight and void ratio are main factors for strength, compressibility and prediction of consolidation behavior. In the past, the physical characteristics of admixed soils could be understanded through complex laboratory tests and field survey after construction. In this study, the tests were performed with conditions such as clay water contents 0%-170%, cement contents 5%-25% and curing period 3-90days after that analyzed for changes which are water content, specific gravity unit weight and void ratio of admixed soils. A prediction of properties through mechanical relationships with clay in situ water content, cement content and curing period could be proposed using the test results. The prediction equation of void ratio of admixed soils was derived using void ratio equation in geotechnical engineering and compared with test results of bangkok clay and then this study could be verified.

Mechanical Characteristics of Porous Concrete using Recycled-Aggregate (순환골재를 이용한 투수성 콘크리트의 역학특성)

  • You, Seung-Kyong;Yu, Nam-Jae;Cho, Sung-Min;Shim, Min-Bo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.17-20
    • /
    • 2007
  • In this study, a series of uniaxial unconfined compression test and constant-head test were performed to investigate the mechanical characteristics of porous concrete using recycled-aggregate for the varying unit weight and water-cement ratio. To enhance the permeability of the porous concrete, the recycled-aggregate with similar grain size in the range of $40{\pm}5mm$ was used and water-cement ratio that leads to the lean-mix was adapted. The mechanical characteristics of the porous concrete cured for 3 days were examined; the compressive strength and $E_{50}$ showed their maximum values with 40% water-cement ratio and $1.8t/m^3$ unit weight and the permeability coefficient was averagely measured in the range of $0.9{\times}10^0cm/sec$ regardless of water-cement ratio and unit weight.

  • PDF

Characteristics of Thermal Conductivity of Concrete Containing Fine Bottom Ash Aggregates (바텀애시 경량골재를 사용한 콘크리트의 열전도율 특성)

  • Park, Ji-Hun;Jung, Hoe-Won;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.596-603
    • /
    • 2020
  • In this paper, an experimental study was conducted to investigate the applications of bottom ash, which is an industrial by-product obtained from thermal power plants. Bottom ash was used as fine aggregate in this study, and an experiment was conducted to determine the characteristics of the bottom ash aggregate. In addition, 25, 50, 75, and 100% contents of crushed (natural) fine aggregate were replaced with bottom ash aggregate to produce concrete mixture including bottom ash. Thereafter, test results of the unit weight, ultrasonic velocity, compressive strength, and thermal conductivity of bottom ash concrete were obtained. Moreover, the effect of the curing ages of 28 and 91 days on the material characteristics of bottom ash concrete were identified. Test results showed that bottom ash used as fine aggregate had pozzolanic reaction. Finally, based on the extensive experimental results, relationships between thermal conductivity and unit weight, ultrasonic velocity, and compressive strength was suggested.

Temperature Effect on the Compaction Characteristic of Cohesionless Soil (온도에 따른 사질토의 다짐 특성)

  • Lee, Kicheol;Ji, Subin;Kim, Hobi;Kim, Dongwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • Among several factors controlling soil compaction, temperature is the factor that varies with region and season. Although earthwork is performed in many projects in the cold regions of the earth, studies on quantifying soil compaction associated with temperature are limited. This experimental study investigates the temperature effect on the soil compaction of cohesionless soil. Jumunjin sand was selected for the tests to represent cohesionless clean sand, which is widely used as an engineering fill at petrochemical projects such as northern Alberta of Canada and Russia. The laboratory test program consists of performing a series of standard proctor tests varying temperature of soil samples ranging from $-10^{\circ}C$ to $17^{\circ}C$. Test results indicate that soil specimen volume expansion occurred from bulking and its range was 0% to 6% with zero above temperature. For increasing temperature from $0^{\circ}C$ to $17^{\circ}C$, water content corresponding to maximum volume (minimum dry unit weight) was decreased and water content corresponding to minimum volume (maximum dry unit weight observed after reaching minimum dry unit weight) was slightly increased with increasing temperature. In zero below temperature, dry unit weight gradually decreased with increasing water content. In this case, no bulking effect was found and soil specimen volume increased due to the higher unit volume of ice.

Strength Characteristics of Epoxy Cement Mortar without Hardening Agent (경화제를 사용하지 않은 에폭시 시멘트 모르타르의 압축강도 특성에 관한 연구)

  • Park, Young-Shik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.4
    • /
    • pp.207-211
    • /
    • 2007
  • The durable lifetime of RC structures is shortened by various reasons, which are the generation of cracks in construction and service term, the exterior deterioration according to climatic condition, the surface damage due to chloride attack and the corrosion of reinforced bars. The durability of concrete structures is nevertheless able to be increased by the method and the material of reinforcement and repair. The epoxy resin is widely used for reinforment and repair of concrete because of the superiority in mechanical property, adhesive property, abrasion resistance, impact resistance and chemical resistance. The epoxy cement mortar with hardening agent has a lot of disadvantages that are troublesome mixing work, weakened weatherability and high cost for hardening agent. In this study, the mix proportion of mortar is presented just only with epoxy resin and some admixtures, and the test result of mortar without hardening agent shows the higher strength than the mortar with hardening agent. In the mix proportion, the weight of epoxy resin must be less than 15% of the unit weight of cement, and 10% of unit weight of cement is adequate for the weight of admixtures.

  • PDF

Property of Thermal Conductivity of Light Weight Panel Core Using Light-Weight Aggregate (인공경량골재를 이용한 경량패널 심재의 열전도 특성)

  • 이정국;도정윤;문경주;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.131-136
    • /
    • 2002
  • In recent year, it has been investigated on the reduction of mass of structures for the purpose of the larger space and the economy with the industry developing very fast and qualitatively. So the purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature zone in use. The compressive strength, flexural strength, unit weight, absorption test and thermal conductivity were practised at 3, 7 and 28 days after manufacturing the light-weight concrete lot the panel core: the filling ratio of continuous void was defied as 40%, 50%, and 60% and water-cement rate was 35, 40 and 45%. As a result of this, it was revealed that the mixture derived from filling ration of void of 50% and water-cement ratio 40% were developing the best properties of the others.

  • PDF

Analysis of Rainfall Infiltration Velocity for Unsaturated Soils by an Unsaturated Soil Column Test : Comparison of Weathered Gneiss Soil and Weathered Granite Soil (불포화토 칼럼시험을 통한 불포화토 내 강우침투속도 분석: 편마암 풍화토와 화강암 풍화토의 비교)

  • Park, Kyu-Bo;Chae, Byung-Gon;Kim, Kyeong-Su;Park, Hyuek-Jin
    • Economic and Environmental Geology
    • /
    • v.44 no.1
    • /
    • pp.71-82
    • /
    • 2011
  • The unsaturated soil column tests were carried out for weathered gneiss soil and weathered granite soil in order to obtain the relationship between rainfall intensity and infiltration velocity of rainfall on the basis of different unit weight conditions of soil. In this study, volumetric water content and pore water pressure were measured using TDR sensors and tensiometers at constant time interval. For the column test, three different unit weights were used as in-situ condition, loose condition and dense condition, and rainfall intensities were selected as 20 mm/h and 50 mm/h. In 20 mm/h rainfall intensity condition, average rainfall infiltration velocities for both gneiss and weathered granite soils were obtained as $2.854{\times}10^{-3}$ cm/s ~ $1.297{\times}10^{-3}$ cm/s for different unit weight values and $2.734{\times}10^{-3}$ cm/s ~ $1.707{\times}10^{-3}$ cm/s, respectively. In 50 mm/h rainfall intensity condition, rainfall infiltration velocities were obtained as $4.509{\times}10^{-3}$ cm/s ~ $2.016{\times}10^{-3}$ cm/s and $4.265{\times}10^{-3}$ cm/s ~ $3.764{\times}10^{-3}$ cm/s respectively. The test results showed that the higher rainfall intensity and the lower unit weight of soil, the faster average infiltration velocity. In addition, the weathered granite soils had faster rainfall infiltration velocities than those of the weathered gneiss soils except for the looser unit weight conditions. This is due to the fact that the weathered granite soil had more homogeneous particle size, smaller unit weight condition and larger porosity.

Development of Weight Type Rounded Snow Plate (중량식 원형 적설판 개발에 관한 연구)

  • Lee, Bu-Yong;Kim, Hyun-Chul
    • Atmosphere
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • We need water equivalent unit data of snowfall for the purpose of forecast and hydrology related research area. This study developed new method of automatic recording snowfall as weight unit with circle type plate using stain-gauge loadcell. Field test of instrument carried out at Daegwallyeong Obs. Station from 20 to 23 Jan. 2008 during heavy snowfall. There is 74.2cm snow depth and 54.6mm precipitation by Daegwallyeong Obs. Station. But the instrument of this study recorded 71.0mm of precipitation amount. Because of different observation method can cause more 15.4mm than Daegwallyeong Obs. Station. But this study gives the possibility of observation of new snow fall measurement under freezing conditions of snow. From the observation data the density of snowfall calculated from 0.09 to $1015g/cm_3$ from the observation period. And have a good relations between manual observation and automatic observation data from this study instrument with slope of 1.35 to 1.39.

An Experimental study on the Structure Application of High Strength Ready Mixed Concrete -part1:Properties of Fresh State- (고강도 레미콘의 구조체 적용에 관한 실험적 연구 -제1보:굳지 않은 상태의 특성-)

  • 이진규;김기철;윤기원;연흥흠;최강순;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.14-17
    • /
    • 1995
  • This study is designed for producing and analyzing the structure application properties of the ready mixed concrete of specified concrete strength about 400kg/$\textrm{cm}^2$ in the batcher plant. And this part is designed for analyzing to the slump, slump flow, air content and unit weight in fresh state. By the test results of fresh concrete state, the slump, slump flow and air content are decreased, but unit weight is increased while open time is passed.

  • PDF