• Title/Summary/Keyword: Unit Testing

Search Result 612, Processing Time 0.03 seconds

Performance Testing of Satellite Image Processing based on OGC WPS 2.0 in the OpenStack Cloud Environment (오픈스택 클라우드 환경 OGC WPS 2.0 기반 위성영상처리 성능측정 시험)

  • Yoon, Gooseon;Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.617-627
    • /
    • 2016
  • Many kinds of OGC-based web standards have been utilized in the lots of geo-spatial application fields for sharing and interoperable processing of large volume of data sets containing satellite images. As well, the number of cloud-based application services by on-demand processing of virtual machines is increasing. However, remote sensing applications using these two huge trends are globally on the initial stage. This study presents a practical linkage case with both aspects of OGC-based standard and cloud computing. Performance test is performed with the implementation result for cloud detection processing. Test objects are WPS 2.0 and two types of geo-based service environment such as web server in a single core and multiple virtual servers implemented on OpenStack cloud computing environment. Performance test unit by JMeter is five requests of GetCapabilities, DescribeProcess, Execute, GetStatus, GetResult in WPS 2.0. As the results, the performance measurement time in a cloud-based environment is faster than that of single server. It is expected that expansion of processing algorithms by WPS 2.0 and virtual processing is possible to target-oriented applications in the practical level.

Investigating Organ Toxicity Profile of Tenofovir and Tenofovir Nanoparticle on the Liver and Kidney: Experimental Animal Study

  • Peter, Aniekan Imo;Naidu, Edwin CS;Akang, Edidiong;Ogedengbe, Oluwatosin O;Offor, Ugochukwu;Rambharose, Sanjeev;Kalhapure, Rahul;Chuturgoon, Anil;Govender, Thirumala;Azu, Onyemaechi O
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.221-229
    • /
    • 2018
  • Tenofovir nanoparticles are novel therapeutic intervention in human immunodeficiency virus (HIV) infection reaching the virus in their sanctuary sites. However, there has been no systemic toxicity testing of this formulation despite global concerns on the safety of nano drugs. Therefore, this study was designed to investigate the toxicity of Tenofovir nanoparticle (NTDF) on the liver and kidney using an animal model. Fifteen adult male Sprague-Dawley (SD) rats maintained at the animal house of the biomedical resources unit of the University of KwaZulu-Natal were weighed and divided into three groups. Control animals (A) were administered with normal saline (NS). The therapeutic doses of Tenofovir (TDF) and nanoparticles of Tenofovir (NTDF) were administered to group B and C and observed for signs of stress for four weeks after which animals were weighed and sacrificed. Liver and kidney were removed and fixed in formal saline, processed and stained using H/E, PAS and MT stains for light microscopy. Serum was obtained for renal function test (RFT) and liver function test (LFT). Cellular measurements and capturing were done using ImageJ and Leica software 2.0. Data were analysed using graph pad 6, p values < 0.05 were significant. We observed no signs of behavioural toxicity and no mortality during this study, however, in the kidneys, we reported mild morphological perturbations widening of Bowman's space, and vacuolations in glomerulus and tubules of TDF and NTDF animals. Also, there was a significant elevation of glycogen deposition in NTDF and TDF animals when compared with control. In the liver, there were mild histological changes with widening of sinusoidal spaces, vacuolations in hepatocytes and elevation of glycogen deposition in TDF and NTDF administered animals. In addition to this, there were no significant differences in stereological measurements and cell count, LFT, RFT, weight changes and organo-somatic index between treatment groups and control. In conclusion, NTDF and TDF in therapeutic doses can lead to mild hepatic and renal histological damage. Further studies are needed to understand the precise genetic mechanism.

Hydrogeological characteristics of the LILW disposal site (처분부지의 수리지질 특성)

  • Kim, Kyung-Su;Kim, Chun-Soo;Bae, Dae-Seok;Ji, Sung-Hoon;Yoon, Si-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.245-255
    • /
    • 2008
  • Korea Hydro and Nuclear Power Company(KHNP) conducted site investigations for a low and intermediate-level nuclear waste repository in the Gyeong Ju site. The site characterization work constitutes a description of the site, its regional setting and the current state of the geosphere and biosphere. The main objectives of hydogeological investigation aimed to understand the hydrogeological setting and conditions of the site, and to provide the input parameters for safety evaluation. The hydogeological characterization of the site was performed from the results of surface based investigations, i.e geological mapping and analysis, drilling works and hydraulic testing, and geophysical survey and interpretation. The hydro-structural model based on the hydrogeological characterization consists of one-Hydraulic Soil Domain, three-Hydraulic Rock Domains and five-Hydraulic Conductor Domains. The hydrogeological framework and the hydraulic values provided for each hydraulic unit over a relevant scale were used as the baseline for the conceptualization and interpretation of flow modeling. The current hydrogeological characteristics based on the surface based investigation include some uncertainties resulted from the basic assumption of investigation methods and field data. Therefore, the reassessment of hydrostructure model and hydraulic properties based on the field data obtained during the construction is necessitated for a final hydrogeological characterization.

  • PDF

A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER (아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구)

  • Cho, Young-Lin;Hwang, Ho-Keel;Cho, Young-Gon;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

Shear bond strength of dentin bonding agents cured with a plasma arc curing light (전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가)

  • Kwon, Young-Chul;Kim, Sun-Young;Chung, Sae-Joon;Han, Young-Chul;Lee, In-Bog;Son, Ho-Hyun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.213-223
    • /
    • 2008
  • The objective of this study was to compare dentin shear bond strength (DSBS) of dentin bonding agents (DBAs) cured with a plasma arc (PAC) light curing unit (LCU) and those cured with a light emitting diode (LED) LCU. Optical properties were also analyzed for Elipar freelight 2 (3M ESPE); LED LCU, Apollo 95E (DMT Systems); PAC LCU and VIP Junior (Bisco); Halogen LCU. The DBAs used for DSBS test were Scotchbond Multipurpose (3M ESPE), Singlebond 2 (3M ESPE) and Clearfil SE Bond (Kuraray). After DSBS testing, fractured specimens were analyzed for failure modes with SEM. The total irradiance and irradiance between 450 nm and 490 nm of the LCUs were different. LED LCU showed narrow spectral distribution around its peak at 462 nm whereas PAC and Halogen LCU showed a broad spectrum. There were no significant differences in mean shear bond strength among different LCUs (P > 0.05) but were significant differences among different DBAs (P < 0.001).

  • PDF

Shear bond strength of dentin bonding agents cured with a plasma arc curing light (전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가)

  • Kwon, Young-Chul;Kim, Sun-Young;Chung, Sae-Joon;Han, Young-Chul;Lee, In-Bog;Son, Ho-Hyun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.213-223
    • /
    • 2008
  • The objective of this study was to compare dentin shear bond strength (DSBS) of dentin bonding agents (DBAs) cured with a plasma arc (PAC) light curing unit (LCU) and those cured with a light emitting diode (LED) LCU. Optical properties were also analyzed for Elipar freelight 2 (3M ESPE); LED LCU, Apollo 95E (DMT Systems); PAC LCU and VIP Junior (Bisco); Halogen LCU. The DBAs used for DSBS test were Scotchbond Multipurpose (3M ESPE), Singlebond 2 (3M ESPE) and Clearfil SE Bond (Kuraray). After DSBS testing, fractured specimens were analyzed for failure modes with SEM. The total irradiance and irradiance between 450 nm and 490 nm of the LCUs were different. LED LCU showed narrow spectral distribution around its peak at 462 nm whereas PAC and Halogen LCU showed a broad spectrum. There were no significant differences in mean shear bond strength among different LCUs (P > 0.05) but were significant differences among different DBAs (P < 0.001)

Application of Oyster Shells as Aggregates for Concrete (콘크리트용 골재로서 굴패각의 활용)

  • 어석홍;황규한;김정규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.540-548
    • /
    • 2002
  • The purpose of this study is to analyze the application of oyster shells (OS) as aggregates for concrete. For this purpose, five reference mixes with W/C ratios of 0.4 ∼0.6 at intervals of 0.05 were used. The replacement proportion of OS was varied with ratios of 0, 10, 30, 50 and 100% by volume of fine or coarse aggregate in the reference mixes. OS was washed and crushed for using as aggregates. New chemical reaction between crushed OS aggregate and cement paste was tested through XRD and SEM analysis. Two strength properties (compressive and flexural) were considered. Strength tests were carried out at the ages of 1, 3, 7, 14 and 28 days. The variations of workability, air content and density, drying shrinkage of the specimens with different proportions of OS were also studied. Finally, the hollow concrete block using OS as a substitute material for fine aggregate was made for testing the application of OS. Experimental results showed that my new chemical reaction did not occur due to mixing OS in concrete. The workability and strengths decreased with increase in proportion of OS. The same trend was observed in density and unit weight, but air content increased due to the inherent pores in OS, which showed a possibility to produce light weight concrete with low strength by using OS as coarse aggregates for concrete. Tests on hollow concrete block showed that the compressive strength and absorption ratio were satisfied with quality requirements when the fine aggregate was substituted with OS up to 50% in volume.

Fire Protection Regulations for Ensuring Fire Safety during Decommissioning Nuclear Power Plants in Korea (해체원전 화재안전 확보를 위한 화재방호 규정 고찰)

  • Kim, Jung-Wun;Park, Chan-Geun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.134-140
    • /
    • 2020
  • Nuclear power plants (NPPs) in Korea are required to be maintained using a defense in-depth approach to prevent leakage of radioactive substances outside the plant and allow safe shutdown in the event of a fire. Periodic testing must be conducted to ensure that the fire protection facilities perform as required by the laws for various nuclear reactor types. In June 2017, for the first time in Korea, a nuclear plant, Kori Unit 1, was permanently shut down. It was prepared for decommissioning in accordance with the fire protection regulations imposed by the regulatory body. However, a standard protocol is necessary for systematically establishing the fire protection program for decommissioning of NPPs in the future. Therefore, the nuclear legal systems of countries with many operating nuclear power plants, such as the United States, Japan, Canada, and various European countries, were reviewed and guidelines for establishing a fire protection program for decommissioning NPPs was suggested; the fire protection requirements stated by Reg Guide 1.191 (Decommissioning fire protection program for NPPs during decommissioning and permanent shutdown) were used as a model. Suggestions for establishing legal regulations to optimize fire protection programs and secure basic technology for decommissioning NPPs were also made.

Implementation and Verification of Dynamic Search Ranking Model for Information Search Tasks: The Evaluation of Users' Relevance Judgement Model (정보 검색 과제별 동적 검색 랭킹 모델 구현 및 검증: 사용자 중심 적합성 판단 모형 평가를 중심으로)

  • Park, Jung-Ah;Sohn, Young-Woo
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.367-380
    • /
    • 2012
  • The purpose of this research was to implement and verify an information retrieval(IR) system based on users' relevance criteria for information search tasks. For this purpose, we implemented an IR system with a dynamic ranking model using users' relevance criteria varying with the types of information search task and evaluated this system through user experiment. 45 participants performed three information search tasks on both IR systems with a static and a dynamic ranking model. Three Information search tasks are fact finding search task, problem solving search task and decision making search task. Participants evaluated top five search results on 7 likert scales of relevance. We observed that the IR system with a dynamic ranking model provided more relevant search results compared to the system with a static ranking model. This research has significance in designing IR system for information search tasks, in testing the validity of user-oriented relevance judgement model by implementing an IR system for actual information search tasks and in relating user research to the improvement of an IR system.

  • PDF

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.