• Title/Summary/Keyword: Unit Testing

Search Result 616, Processing Time 0.022 seconds

An Experimental Study on the Optimum water-cement ratio of Antiwashout underwater concrete (수중불분리콘크리트의 최적 W/C에 관한 연구)

  • 윤재범;어영선;김종수;김명식;백동일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.277-283
    • /
    • 1998
  • In this study we changed W/C into 45, 50, 55, 60%, mixed sea sand which is often used as a replacing aggregate according to the lack of recourse with river sand in the ratio of 5:5 and producted antiwashout underwater concrete. We measured slump flow, air value, pH and suspension in the fresh concrete. After testing each W/C through unit weight and compressive strength of specimen which is produced and cured in the air and salt water it was founded that if sea sand was properly used after salt manufacturing, there will be no bad influence to antiwashout underwater concrete. The characteristic of them showed excellent, when W/C was 50%.

  • PDF

Economic and Fast-track Rehabilitation of Concrete Pavements and Bridge Decks

  • Ramseyer, Chris;Chancellor, Brent;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • The last 10 years have seen considerable growth in the use of proprietary and special repair cements for concrete pavements in the state of Oklahoma. Many of these products lend themselves to "fast track" construction techniques that allow reopening to traffic within 12 hours or less. These products achieve high early strengths by accelerating the Portland cement hydration process for both Type I and Type III cements. In this paper, the important features of a durable repair which include strength, compatibility and bond or adhesion are first discussed. Then the development, testing and field implementation of the aforementioned materials are discussed including the learning curve required to implement a repair system, not just install a new material. Some of the materials discussed, while expensive on a cost per unit basis, hold great promise for economical use on fast track project.

Comparison of Performances refer to Magnetic and Fluid Analysis of Magneto-Rheological Flow Damper (자기점성유체 댐퍼의 자기장 및 유동 해석에 따른 성능비교)

  • Song, Jun-Han;Son, Sung-Wan;Lee, Gyu-Seop;Chun, Chong-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.98-102
    • /
    • 2009
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. To manufacture the magneto-rheological fluid damper that uses such characteristics of the fluid, a flow analysis of the inner damper was conducted to forecast the damper's capacity. In addition, using the finite element method software, analysis on the characteristics of electromagnetic field around the coil operation unit inside the damper. Based on the result of the analysis, a single core damper and a double core damper were built and tested for their dynamic function. Based on the result of the experiment, the propriety of the flow analysis was demonstrated, and the proposed model was verified.

  • PDF

Development of Probability Computation Program for Standard Normal Distribution (표준정규분포의 확률계산 프로그램 개발)

  • 송서일
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.182-192
    • /
    • 1997
  • The well-known standard normal distribution has been used within the limit of standard variable value of u=3.59. However, the probability values above the limit are not given in the literature. In this study, a probability computation program for standard normal distribution to u=5.99 with the proportional normal distribution a, pp.oximation suggested by Abramowitz and Stegun, Hastings is developed. The new standard normal distribution table developed by the program is presented and will be of help to estimate of probability values for testing and estimation of process mean value, lot acceptable probability, defective percentage of PPM unit of an out-of specification limit, process capability, test power of control charts, probability and statistics.

  • PDF

Injection Mold of Through Plate Type for Recycling (재생 관통형 형판구조의 사출금형 개발)

  • 송준엽;박태원;재덕근;정영득
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.123-129
    • /
    • 2003
  • Recently, the life cycle of products is rapidly shortened and then the disposal of the used mold applied in development of the product is a difficult thing. In this study, we proposed the feasibility of new three plate type mold structure for recycling by analyzing of the existing standard mold base. And in order to apply new three plate mold structure in mold design and making. we constructed the specifications for mold parts such as runner stripper plate, cavity plate, core plate and slide core unit. Also, we confirmed the possibility of recycling mold base by testing a used three plate mold for audio front panel.

Estimation for the Rayleigh distribution based on Type I hybrid censored sample

  • Kwon, Byongwon;Lee, Kyeongjun;Cho, Youngseuk
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.2
    • /
    • pp.431-438
    • /
    • 2014
  • Type I hybrid censoring scheme is the combination of the Type I and Type II censoring scheme introduced by Epstein (1954). Epstein considered a hybrid censoring sampling scheme in which the life testing experiment is terminated at a random time $T^*$ which is the time that happens rst among the following two; time of the kth unit is observed or time of the experiment length set in advance. The likelihood function of this scheme from the Rayleigh distribution cannot be solved in a explicit solution and thus we approximate the function by the Taylor series expansion. In this process, we propose four dierent methods of expansion skill.

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

Asymptotic Relative Efficiency of Chi-squared Type Tests Based on the Empirical Process

  • Lee, Sang-Yeol
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.3
    • /
    • pp.337-346
    • /
    • 1996
  • The chi-squared type statistic generated from the empirical process can be used for testing the goodness of fit hypothesis on iid random sample. Lee (1995) showed that under some conditions, the chi-squared type statistic is asymptotically maximin in the sense of Strasser (1985). Since the chi-squared type statistic depends on the choice of *points in the unit interval, it is worth investigating the points yielding more efficient tests. Motivated by this viewpoint, we are led to study the asymptotic relative efficiency of chi-squared type tests in the same setting of Lee (1995). Some examples are given for illustration.

  • PDF

The effect of hexamethylenetetramine contents and cure properties on friction characteristics of phenolic resin (페놀수지의 마찰특성에 미치는 HEXA의 함량 및 경화도의 영향)

  • Kim, Dae-Kyeun;Jang, Ho;Yoon, Ho-Gyu
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.49-56
    • /
    • 1999
  • A material was formulated with Phenol novolac and HEXA only. The cure kinetics and thermal characteristics of phenol novolac with various HEXA contents were peformed by differential scanning calorimetry and thermal gravimetric analysis. All kinetic parameters of the curing reaction including the reaction order, activation energy, and rate constant were calculated and reported. The results indicate that the curing reaction goes through an autocatalytic kinetic mechanism. The friction and wear characteristics of this material were determined using friction material testing machine. The friction coefficient of phenol novolac with various HEXA contents was determined using the PV(pressure & velocity) factor. The most stable and highest friction coefficient with a various pressure and velocity condition was found at HEXA 10 wt.% material. The specific wear rate per unit sliding distance with a various HEXA contents was reported.

  • PDF

Establishment of Response Instrumentation Test Acceptance Criteria for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program (APR1400 원자로내부구조물 종합진동평가 응답측정시험 허용기준 수립)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.212-218
    • /
    • 2011
  • APR1400 RVI CVAP using the non-prototype category is being conducted to verify integrity of the RVI design and to secure the CVAP technology. The measurement programs are to confirm vibration analysis results for reactor internals during preoperational and initial startup testing and to detemine the safety margin. One of the important basis for the measurement programs is test acceptance criteria. Therefore, this paper is on establishment of response instrumentation test acceptance criteria for APR1400 RVI CVAP. The established acceptance criteria show that the stress criteria of APR1400 RVI are more conservative values than those of the valid prototype plant(Palo Verde unit 1) and, the displacement criteria of the IBA and the UGS were established to 0.03 in and 0.01 in, respectively.

  • PDF