• 제목/요약/키워드: Underground vibration

검색결과 269건 처리시간 0.021초

22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구 (A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable)

  • 김창교;홍진수;정영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF

지중진동 측정을 통한 흙막이 근접발파 영향 연구 (Study on the Effect of Near Blasting to Earth Retaining Wall by Measuring Underground Vibrations)

  • 조래훈;정병호
    • 화약ㆍ발파
    • /
    • 제33권4호
    • /
    • pp.14-24
    • /
    • 2015
  • 근접발파진동이 흙막이 안정성에 미치는 영향을 알아보기 위해 3개 현장에서 시험발파를 시행하였다. 시험결과 동일거리의 지중에서 측정된 진동은 지표에서 측정된 진동의 10~52% 수준으로 작아 어스앵커 정착장 등 지중에 설치된 구조물은 지표에 있는 구조물에 비해 상대적으로 발파진동에 안전함을 확인하였다. 측정된 3개 현장의 지표 및 지중진동 PPV를 통합 회귀분석하여 진동추정식을 도출하였으며, 이를 활용 지중 및 지표에서 양생중인 콘크리트에 대해 양생시간별 허용진동기준을 만족하는 발파패턴별 최소이격거리를 산정하였다. 근거리 발파진동 측정, 흙막이 계측치 변화 확인, 구조물 변형여부 육안관찰을 통해 확인한 결과 특별히 흙막이 안정성에 불리한 불연속면이 발달하지 않는 한 지발당장약량 2.4kg 이하의 발파작업은 흙막이 안정성에 유의미한 영향을 미치지 않는 것으로 판단된다.

The effect of blast-induced vibration on the stability of underground water-sealed gas storage caverns

  • Zhou, Yuchun;Wu, Li;Li, Jialong;Yuan, Qing
    • Geosystem Engineering
    • /
    • 제21권6호
    • /
    • pp.326-334
    • /
    • 2018
  • Underground water-sealed gas storage caverns have become the primary method for strategic storage of LPG. Previous studies of excavation blasting effects on large-scale underground water-sealed gas storage caverns are rare at home and abroad. In this paper, the blasting excavation for underground water-sealed propane storage caverns in Yantai was introduced and field tests of blasting vibration were carried out. Field test data showed that the horizontal radial velocity had a major controlling effect in the blasting vibration and frequencies would not cause the vibration velocity concentration effects. In terms of the influence of blasting vibration on adjacent caverns, the dynamic finite element model in LS-DYNA soft was established, whose reliability was verified by field test data. The numerical results indicated the near-blasting side was primary zone for the structural failure and tensile failure tended to occur in the middle of the curved wall on the near-blasting side. Meanwhile, the safety criterions for adjacent caverns based on stress wave theory and according to statistic relationship between peak effective tensile stress and peak particle velocities were obtained, respectively. Finally, with Safety Regulations for Blasting in China (GB6722-2014) taken into account, a final safety criterion was proposed.

발파진동에 의한 절리암반 지하공동의 낙석발생 예측에 관한 수치해석적 연구 (Numerical Study for Prediction of Rock Falls Around Jointed Limestone Underground Opening due to Blast Vibration)

  • 김현수;김승곤;조상호
    • 화약ㆍ발파
    • /
    • 제34권3호
    • /
    • pp.10-16
    • /
    • 2016
  • 최근 석회석광산은 분진 소음 등 환경적인 문제와 함께 석회석 품위 저하 현상으로 갱내 채광이 증가하고 있다. 석회석을 파쇄시키기 위한 파쇄 시설을 갱내 설치하려면 대규모 지하공동이 필요하게 되며, 공동의 규모가 커짐에 따라 낙석이나 낙반의 발생 가능성이 높아지게 된다. 그리고 석회석 지하공동 주변 암반은 다양한 절리가 발달하여 낙석 발생에 영향을 미치는 것으로 알려져 있다. 본 연구에서는 채광 발파 시 대형갱도 내 낙석발생 여부 관찰과 발파진동 계측을 수행하여, 이를 바탕으로 불연속면 수치해석 소프트웨어인 UDEC를 이용하여 절리암반 동해석 모델을 제안하고 발파진동 여기에 의한 대형 지하갱도의 낙석 발생을 해석하였다. 또한 절리암반 모델에 다양한 절리특성(경사각, 간격)의 변화와 발파굴착 손상영역을 고려하였다.

열차하중에 의한 지중구조물의 소음진동감소를 위한 차단벽사용에 관한 연구 (A Study on Using Infilled Trenches for Vibration Reduction of Underground Structures by Train Loading)

  • 권기준;정대열;고철수;김용길;황성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.724-729
    • /
    • 2003
  • Installing vibration isolation in structures, such as structures adjacent to subways, may be delicatebecause of the proximity with the vibration source or because of the wave propagation path. This paper discusses on method that install isolation Pads on underground walls as a part of the vibration mitigation system, and also on its efficiency, The proposed method is proven to affect significantly the distribution of acceleration in the neighborhood of the structure and to reduce efficiently the maximum amplitude of the vibration. It is also seen that installing isolating pads until the depth of the foundations and deeper is more efficient than installing such device separately from the structure. This Study being limited to the comparison of installation methods, further Studies considering the thickness, stiffness and other parameters should be required.

  • PDF

지중 전력 케이블 가압 상태 진단 (Identification of Energized status of Underground Power Cable)

  • 김창교;홍진수;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 1998
  • A study to identify the energized status of the 22.9kV underground power cable by the detection of vibration was reformed. We derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The vibration can be picked up by accelerometer sensor. A prototype was tested on the underground distribution system in Chonan Station, KEPCO. The results are presented and suggest the applicability of the detecting device.

  • PDF

Autonomous evaluation of ambient vibration of underground spaces induced by adjacent subway trains using high-sensitivity wireless smart sensors

  • Sun, Ke;Zhang, Wei;Ding, Huaping;Kim, Robin E.;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2017
  • The operation of subway trains induces secondary structure-borne vibrations in the nearby underground spaces. The vibration, along with the associated noise, can cause annoyance and adverse physical, physiological, and psychological effects on humans in dense urban environments. Traditional tethered instruments restrict the rapid measurement and assessment on such vibration effect. This paper presents a novel approach for Wireless Smart Sensor (WSS)-based autonomous evaluation system for the subway train-induced vibrations. The system was implemented on a MEMSIC's Imote2 platform, using a SHM-H high-sensitivity accelerometer board stacked on top. A new embedded application VibrationLevelCalculation, which determines the International Organization for Standardization defined weighted acceleration level, was added into the Illinois Structural Health Monitoring Project Service Toolsuite. The system was verified in a large underground space, where a nearby subway station is a good source of ground excitation caused by the running subway trains. Using an on-board processor, each sensor calculated the distribution of vibration levels within the testing zone, and sent the distribution of vibration level by radio to display it on the central server. Also, the raw time-histories and frequency spectrum were retrieved from the WSS leaf nodes. Subsequently, spectral vibration levels in the one-third octave band, characterizing the vibrating influence of different frequency components on human bodies, was also calculated from each sensor node. Experimental validation demonstrates that the proposed system is efficient for autonomously evaluating the subway train-induced ambient vibration of underground spaces, and the system holds the potential of greatly reducing the laboring of dynamic field testing.

실측진동파형을 이용한 석회석 갱내채광장의 안정성 분석 연구 (A Study on the Stability Analysis of Underground Limestone Openings using the Measurement Vibration Waveform)

  • 김병렬;이승중;최성웅
    • 터널과지하공간
    • /
    • 제28권5호
    • /
    • pp.457-475
    • /
    • 2018
  • 본 연구에서는 갱내채광장의 발파현상을 보다 현실적으로 수치해석상에서 반영하기 위하여 현장에서의 발파를 통해 획득한 발파진동 파형을 발파지점의 진동속도로 변환하여 이를 동적수치해석의 입력 자료로 직접 활용하였다. 석회석 갱내채광장의 지질특성과 채광단계를 반영한 수치모델을 구성하였으며, 이를 바탕으로 동적수치해석을 수행하여 석회석 갱내광산의 발파작업이 채광장의 안정성에 미치는 영향을 분석하였다. 해석결과와 현장에서 계측된 발파진동의 비교를 통하여 실측발파진동의 적정성을 확인하였으며, 연속되는 채광작업은 응력의 교란에 의한 천반붕락 및 채굴공동 주변의 활동성 파괴영역의 발생을 야기할 수 있는 것으로 분석되었다. 이로부터 연구대상 광산에서의 안정적인 채광활동을 위해서는 추가적인 보강대책이 필요할 것으로 판단된다.

지하철 차량운행에 의한 진동영향 평가: State of the Art (Prediction and Control of the Propogation of Underground Train Systems-induced Ground Vibration: State of the Art)

  • 이인모;최상순;밝보리나라
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 학술발표집 지반진동 영향평가
    • /
    • pp.73-82
    • /
    • 1993
  • Ground-borne vibration is one of the main causes of environmental impact from subway systems. The vibration resulting from track-train interaction is transuutted through the tunnel structure and the surrounding ground to adjacent buildings. This paper provides a summary of proposed noise and vibration criteria, a review of the ground vibration propagation mechanism and the theoretical isolation effectivenesss of each of the following underground transit systems : track, tunnel and vehicle itself.

  • PDF

지중 구조물의 지반 진동 안전거리 설정에 관한 현장적용연구 (A Study on the Safety Distance of Underground Structures in Asepct of Ground Vibration Velocity due to Explosions)

  • 박상진;강지원;박영준
    • 한국건설관리학회논문집
    • /
    • 제17권4호
    • /
    • pp.87-94
    • /
    • 2016
  • 탄약고 지하 및 주변에 시공된 지하구조물의 안정성 평가의 필요성은 도심지 및 사회기반시설의 확장으로 대두되었다. 그러나 지하구조물에 대한 우발적인 폭발의 영향에 대한 연구는 미진하다. 본 연구에서는 지하구조물의 안정성평가를 위한 방법을 제시하고 사례연구를 통해 적용성을 확인하였다. AUTODYN과 SPACECLAIM을 이용하여 구조체 및 지반모델링을 실시하였으며, 폭발효과를 모의하여 지반의 진동속도를 측정하였다. 사례연구의 결과에 따르면, 70m 지하에 설치된 지하구조물은 모의된 폭발 효과로부터의 영향이 거의 없는 것으로 판단된다. 본 연구에서 활용된 안정성평가방법은 지하형 탄약고 설계에 사용되거나, 혹은 주기적인 진동으로부터 영향하에 있는 지하구조물의 안정성을 평가하는데 활용될 수 있을 것이다.