• Title/Summary/Keyword: Underground facility

Search Result 379, Processing Time 0.028 seconds

Characteristics of defect on segmental lining of TBM tunnel in operational subway (운용중인 국내 지하철 TBM터널의 세그먼트라이닝 결함특성 분석)

  • Choo, Jinho;Lee, DongHun;Noh, EunChul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.109-128
    • /
    • 2022
  • The precise inspection for safety and diagnosis (PISD) of tunnel has been conducted by the special act on safety control of public structures. However, the present assessment for the segmental lining of TBM tunnel has limitation such as: NDTs for integrity, segmental configuration for field inspection, and consideration for jacking system. Even if the number of TBM tunnel is less than 1% of enrolled facility in FMS, more attention to maintenance should be necessary due to its usage such as multi-use facility and national important facility. Compared to NATM tunnel, excavated by drilling and blasting and then installed lining by cast-in-place within 6~12 m, TBM tunnel is cut out ground by disk and cutter-bit and then assembled 7 pieces of precast segment, 1.2~1.4 m wide. Different features of design, construction, and maintenance should be considered to be more exact evaluation of TBM tunnel. The characteristics of defect is categorized and analyzed with 11 operational TBM tunnels in domestic subway. To be more comprehend various particular defects, foreign studies have been also adapted. Crack and leakage are categorized in 7 patterns. Breakage/spalling and corrosion are also grouped into 3 patterns. Patterned defects or damages are fed back in design, construction, and are useful guidelines for maintenance stage in future.

A Physical Model Test on Behavior of Shield-tunnel Lining according to Drain Conditions (배수조건에 따른 쉴드터널 라이닝의 거동연구를 위한 모형실험)

  • Choi, Gou-Moon;Yune, Chan-Young;Ma, Sang-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.5
    • /
    • pp.55-65
    • /
    • 2014
  • Most shield tunnels are designed based on the assumption of a undrained condition. But they are operated as drained tunnels in which underground water flows and passes through a drainage facility. Therefore, it is necessary that the drainage condition be considered in the shield tunnel design. In this research, new testing device which can simulate the underground tunnel located below ground water level, was developed. Total stress and pore water pressure were examined and an inflow water into an inner pipe was measured using the testing device. Test results showed that the total stress, which was the sum of effective stress and pore pressure, increased more in an undrained condition and an inflow water into an inner pipe was proportional to the water pressure but inversely proportional to the loading stress. Consequently, if the drainage is considered in the shield tunnel design, the more economical design can be expected because of the stress reduction of the lining.

A Study on the Symbolization of the Underground Visual Elements as a Signification-Function -Focus on the Environmental Graphics of the Subway Vehicle & Station in Seoul City- (지하 시각요소의 표지기능(標識機能)적 상징성에 관한 연구 -서울시 지하철 및 지하역(驛)의 환경그래픽을 중심으로-)

  • 김경만
    • Archives of design research
    • /
    • no.18
    • /
    • pp.153-162
    • /
    • 1996
  • underground space have many negative environmental clements which should be confirmed on location and line of action by the artificial signs. iccordingly, environmental graphics as visual language for popular signification-function have to be studied on sign theory of symbolic meanings. Ho\/ever, its usage has not only decorated by microscopiC appreciative eye but also lost its meanlllg as a visual language which was caused by the negligence of systematic management of the facility in charge Result of study, Visual environmental factors as a cause of behavioral attitude based on the study, which has been carefully considered as a communication of the visual language. Therefore, considering the underground environmental graphics as the: sign or the signification-function, It has to be studied on syntactic, semantic and pragmatic viewpoint. SpeCifically, to maKe the color and formation language a signification-function as a generalized connotation to the public, a distinctive classified Visual language must be applied.

  • PDF

Reduction of Rainfall Runoff by Constructing Underground Storage Tank (지하저류조 신설에 따른 우수 유출량 저감)

  • Song, Chang Geun;Seo, Il Won;Jung, Young Jai
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.927-935
    • /
    • 2013
  • In this study, reservoir routings for 1 hour-50 year precipitation frequency were carried out at the Engineering Water Fall and the Amphitheater located at the downstream of Seoul National University Dam. Main analysis was focus on the following matters: (1) storage amount by the tank; (2) reduction of the outflow and the peak water surface elevation; (3) change of phase lag time; and (4) design of new boxes at the inlet and outlet of storage tank. As for the storage tank of $25,000m^3$ built in the Amphitheater area, the tank induced 49.43 % storage effect, 28 min. phase lag time, and reduced the peak outflow by 49.64 %. In addition, the peak water surface elevation was lowered by 35 cm compared with that of $15,000m^3$ storage tank. It is concluded that combined management of previous storage facility and new underground storage tank would control the excessive rainfall runoff efficiently.

Three-dimensional Stability Analysis for an Underground Disposal Research Tunnel (지하처분연구시설에 대한 3차원 터널 안정성 해석)

  • 권상기;조원진
    • Tunnel and Underground Space
    • /
    • v.14 no.3
    • /
    • pp.188-202
    • /
    • 2004
  • If an underground research facility for the validation of disposal concept is constructed in KAERI, it is expected to have a thick weathered zone and varying surface topology. In this study, the influence of different geological conditions, tunnel slope, tunnel size, and sequential excavation is investigated by 3D mechanical analysis using FLAC3D. Around the tunnel, it is not expected to develop any plastic zone and the maximum stress might be as high as 5 ㎫. The maximum compressive stress will be developed at about 20 m to e dead end of the tunnel. There is no difference on stress and displacement distributions between the cases with and without sequential excavation. It is expected to have stress release in the roof and floor after the excavation of the tunnel. There is no significant influence of weathered zone size, tunnel size, and tunnel slope on the stress and displacement distributions. The modeling for the intersection shows the minimum factor of safety is above 3, when the in situ stress ratio K is 3. From the study, it was possible to demonstrate that the small scale disposal research tunnel in KAERI will be mechanically stable.

An Experimental Study on Permeability Characteristics of Blast Furnace Slag Concrete (고로슬래그 콘크리트의 투수특성에 관한 실험적 연구)

  • Paik, Shinwon;Oh, Daeyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.9-12
    • /
    • 2013
  • The pavement is generally used on the highways, local loads, roads for bicycle riding and neighborhood living facility such as parking lot, plaza, park and sports facilities. However, the pavement material that is usually used on the most of roads is impermeable asphalt-concrete and cement-concrete. If the pavement material is impermeable, many problems can be happened on the drainage facilities in the rainy season. Additionally, a lot of rainwater on the pavement surface cannot permeate to the underground and flows to the sewage ditch, stream and river, etc. If a lot of rainwater flows at once, the floods can be out along the streams and rivers. So, underground water can be exhausted. Micro organisms cannot live in the underground. Recently, many studies has been conducted to exploit the permeable concrete that has high performance permeability. However, it is required to develop the permeable concrete which has high strength and durability. In this study, permeable and strength tests were performed to investigate the permeable characteristics of porous concrete according to fine aggregate content and substitution ratio of blast furnace slag. In this test, crushed stones with 10~20 mm and sand with 5~10 mm were used as a coarse aggregate and a fine aggregate respectively. The substitution ratio of blast furnace slag to cement weight is 0 %, 15 %, and 30 %. The ratio of fine aggregate to total aggregate is 0 %, 18 %, and 35 %. As a result, permeability coefficient was decreased according to fine aggregate ratio of total aggregate. Compressive strength was also decreased according to substitution ratio of blast furnace slag.

An Estimation of the Consequence Analysis for an Underground Installation of the LPG Storage Tanks (소형 LPG 저장탱크 매몰 설치에 대한 피해영향평가)

  • Song, Dong-Woo;Jun, Woon-Young;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.62-67
    • /
    • 2015
  • In this paper, the consequence analysis has been evaluated for the damage effects of the LPG storage tanks when they are installed on the ground or underground. They should be performed to identify measures to reduce risks for the LPG storage tanks which are more widely used. In order to conduct a damage effect evaluation of the LPG storage tanks installed underground, FDS was used to simulate the LPG storage tanks installed and housed within a facility. The maximum pressure of the storage facilities for the LPG storage tanks has been calculated from the FDS, and it's results are used as an input variable for Phast which is a commercial software for evaluating the damage effects. Getting results from the consequence analysis and computational simulations(diffusion range of LFL and UFL, jet fire or explosions) were quantitatively presented for the damage effects.

Finite Element Analysis of Silo Type Underground Opening for LILW Disposal Facility (사일로 구조형식 중저준위 방폐물 처분동굴의 유한요소 해석)

  • Kim, Sun-Hoon;Kim, Kwang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.339-345
    • /
    • 2021
  • Finite element analysis of the silo type underground opening for low- and intermediate-level radioactive waste (LILW) disposal facilities in Korea is presented in this study. The silo wall is circular and the roof is made up of domes. The silo wall is 25 meters in diameter, 35 meters in height, and the dome is 30 meters in diameter and 17.4 meters in height, and it is located at -80 meters to -130 meters at sea level. Although six silos have been constructed in the first stage and are in operation, only one silo was considered in this study. The two-dimensional axial symmetric finite element model, as well as the three-dimensional finite element model were made using the computer program SMAP-3D. Generalized Hoek and Brown Model was used for the numerical analyses. The finite element analysis of the silo type underground opening was carried out under various lateral pressure coefficients (defined as ratio of average horizontal to vertical in-situ stress), and the numerical results of these analyses were examined.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

Design and Construction Study of an Injection Facility for CO2 Offshore Storage (CO2 해상 지중저장을 위한 주입설비 설계 및 구축 연구)

  • Moon, Hung-Man;Kim, Hyo-Joon;Shin, Se-Jin;Lee, Yong-Il;Kwon, Si-Hyun;Kwon, Yi-Kyun
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2018
  • Almost all countries of the world have recently made great efforts to reduce green-house gases to alleviate the global warming threatening human survival, because a huge amount of carbon dioxide as one of the main green-house gases has been emitted from the combustion processes of fossil fuels such as coal and oil. $CO_2$ capture and storage (CCS) technology is a representative method to diminish the green-house gases, and actively investigated by many countries. This study focuses on the design and construction of a high pressure $CO_2$ injection facility to store it to underground, which is the first $CO_2$ injection in Korea following the steps of the $CO_2$ capture from large $CO_2$ emission sources and transportation to the sea. Injection tests of $CO_2$ on the platform on the sea were carried out in Yeongil Bay of Pohang city in the early 2017. Thus, we were able to perceive the necessary operating conditions of the injection facility, injection characteristic, and knowhow of the injection facility. The results obtained from the injection test shall be utilized for facility upgrades and scale-ups.