• Title/Summary/Keyword: Underground Facility

Search Result 378, Processing Time 0.026 seconds

A Study on Development of 3D Data Model for Underground Facilities Using CityGML ADE (CityGML ADE를 이용한 3차원 지하시설물 데이터 모델 개발에 관한 연구)

  • Jeong, Da Woon;Shin, Dong Bin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.4
    • /
    • pp.245-252
    • /
    • 2021
  • Underground facilities were constructed as needed by various management organizations, the result of which was the disordered and scattered underground spaces. This phenomenon can be viewed as the main cause of safety accidents in the underground space. To solve this problem, research on systematic construction and management of underground facilities should be conducted. Therefore, to improve the accuracy and the quality of information and to facilitate the systematic construction and management of underground facility information, this study aims to establish a 3D data model that conforms to international spatial information standards for pipeline underground facilities and to implement the data model to enable visualization. The result of this study can be used to improve the consistency of information not only between underground facilities, but also the correspondence between above ground and underground facilities. As such, this study has academic significance in that it presents an integrated data model that includes various objects in the ground and underground spaces and enables interoperability between diverse domain data.

A study on the concentration distribution of CO and $CO_2$ by a form of parking lot in the multiplex use facility (다중이용시설의 주차장 형태에 따른 CO, $CO_2$ 의 농도분포에 관한 연구)

  • Sin, Ji-Won;Kim, Tea-Woo;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.316-321
    • /
    • 2006
  • Multiplex use facility emphasized the importance of indoor air environment because many people using that place. People using parking lot of multiplex use facility in little time, but a pollutant of in indoor air menacing user health. This study measure and analyze the CO, $CO_2$ for better air quality of an indoor parking lot in the multiplex user facility. As a result, two-way opened above ground parking lot is higher numerical value of CO, $CO_2$ than an underground parking lot. And a parking lot of square form is higher numerical value of $CO_2$ than a parking lot of rectangle form.

  • PDF

A Printed Yagi Antenna Available at 2.4 GHz for Remote Management of Underground Facility (지하 매설물 원격 관리를 위한 2.4 GHz 대역의 인쇄형 야기 안테나)

  • Park, Dong-Kook;Cho, Ik-Hyun;Seo, Hong-Eun;Yun, Na-Ra;Kim, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1360-1366
    • /
    • 2008
  • This paper proposes a printed yagi-antenna available at 2.45 GHz, for the remote-management system of the underground equipment. To improve the solidity and waterproof property, the proposed antenna is coated with bakelite. The manufactured antenna is operated at $2.15{\sim}2.52\;GHz$, whose gain measures 10 dBi. These results are a little different from those of the simulated antenna, but the trend is totally similar. Developed antenna is expected to be useful in the underground facility.

Determination of Radionuclide Concentration Limit for Low and Intermediate-level Radioactive Waste Disposal Facility I : Application of IAEA Methodology for Underground Silo Type Disposal Facility (중저준위 방사성폐기물 처분시설의 처분농도제한치 설정에 대한 고찰 I : IAEA 방법론의 동굴처분시설 적용)

  • Hong, Sung-Wook;Kim, Min Seong;Jung, Kang Il;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.257-264
    • /
    • 2017
  • For the safe disposal of intermediate level radioactive waste according to the Nuclear Safety and Security Commission's notice and KORAD's management plan for low and intermediate level radioactive waste, the disposal concentration limit was derived based on the IAEA methodology. The evaluation of the derived disposal concentration limit revealed that it is not suitable as a practical limit for intermediate level radioactive waste. This is because the disposal concentration limit according to the IAEA methodology is derived using a single value of radioactive waste density and the disposal facility's volume. The IAEA methodology is suitable for setting the concentration limit for vault type disposal, which consists of a single type of waste, whereas an underground silo type disposal facility is composed of several types of radioactive waste, and thus the IAEA methodology has limitations in determining the disposal concentration limit. It is necessary to develop and apply an improved method to derive the disposal concentration limit for intermediate level radioactive waste by considering the radioactivity of various types of radioactive waste, the corresponding scenario evaluation results, and the regulatory limit.

Research Status on the Radionuclide and Colloid Migration in Underground Research Facilities (지하연구시설에서 핵종 및 콜로이드 이동 연구 현황 분석)

  • Baik, Min-Hoon;Lee, Jae-Kwang;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.4
    • /
    • pp.243-253
    • /
    • 2009
  • In this study, research status on radionuclide and colloid migration in underground research facilities including KURT (KAERI Underground Research Tunnel) was investigated. Some foreign underground research facilities constructed in crystalline rock formations such as granite were briefly introduced and compared. International joint researches concerned with the radionuclide and colloid migration were investigated particularly for the Grimsel Test Site (GTS) and $\ddot{A}$sp$\ddot{o}$ Hard Rock Laboratory by analyzing major research items, on-going research projects, and future plans.

  • PDF

A comparative study on the behavior of dynamic analysis and pseudo-static analysis considering SSI of a tall building and an adjacent underground structure (초고층 빌딩과 인접 지하구조물의 SSI를 고려한 동적해석과 유사정적해석의 거동 비교 연구)

  • You, Kwang-Ho;Kim, Seung-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.671-686
    • /
    • 2018
  • Recently, earthquakes have occurred near Gyeongju and Pohang and the social demands are thus being increased for seismic analysis of tall buildings and their adjacent underground structure in big cities. Since most of the previous seismic analysis studies considered a tall building and an adjacent underground structure separately, however, they lack the analysis on dynamic mutual behavior between two structures. Therefore, in this study, a dynamic analysis with a full soil-structure interaction was performed for a complex underground facility with a tall building and an adjacent underground structure constructed on the bedrock with a surface layer. To improve the reliability, in particular, a pseudo-static analysis was performed and compared with the dynamic analysis results. It is comprehensively concluded that the analysis of adjacent underground structures being considered is more conservative than that of not considered.

In-situ Rock Stress Measurement at the Water Tunnel Sites in the OO Oil Storage Facility with Hydraulic Fracturing Method (수압파쇄법을 이용한 OO 원유비축시설 내 수벽 터널에서의 초기응력 측정)

  • Bae, Seong-Ho;Kim, Jae-Min;Kim, Jang-Soon;Lee, Young-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • The influence of in-situ rock stress on the stability of an underground rock structure increases as the construction depth become deeper and the scale of a rock structure become larger. In general, hydraulic fracturing stress measurement has been performed in the surface boreholes of the target area at the design stage of an underground structure. However, for some areas where the high horizontal stresses were observed or where the overstressed conditions caused by topographical and geological factors are expected, it is desirable to conduct additional in-situ stress measurement in the underground construction site to obtain more detailed stress information for ensuring the stability of a rock structure and the propriety of current design. The study area was a construction site for the additional underground oil storage facility located in the south-east part of OO city, Jeollanam-do. Previous detailed site investigation prior to the design of underground structures revealed that the excessive horizontal stress field with the horizontal stress ratio(K) greater than 3.0 was observed in the construction area. In this study, a total of 13 hydraulic fracturing stress measurements was conducted in two boreholes drill from the two water tunnel sites in the study area. The investigation zone was from 180 m to 300 m in depth from the surface and all of the fracture tracing works were carried out by acoustic televiewer scanning. For some testing intervals at more than 200 m ind depth from surface, the high horizontal stress components the horizontal stress ratio(K) greater than 2.50 were observed. And the overall investigation results showed a good agreement with the previously performed test.

A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island (제주지역 일부 농업 시설 내 라돈 농도 예비 조사)

  • Kang, Tae-Woo;Song, Myeong-Han;Kim, Tae-Hyoung;Chang, Byung-Uck;Kim, Young-Jae;Kim, Geun-Ho;Park, Jae-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • BACKGROUND: A preliminary investigation of the radon ($^{222}Rn$) concentration has been conducted, employing solid-state nuclear-track detectors (SSNTD) and a continuous radon monitor (CRM), for fourteen randomly selected agricultural greenhouses in Jeju Island, where the underground-air was used for air conditioning and $CO_2$ supplement. METHODS AND RESULTS: The SSNTD was used to measure the average radon concentration for three months and the CRM was used for an instantaneous measurement. In order to obtain the radon concentration of a greenhouse, the SSNTDs were placed at a number of evenly distributed points inside the greenhouse and the mean of the measured values was taken. In addition, in order to assess the radon concentration of the underground-air itself, measurement was also made at the borehole of the underground-air in each agricultural facility, employing both the SSNTD and CRM. It is found that the radon concentration of the greenhouses ranges higher than those not using the underground-air and the average of Korean dwellings. While the radon concentration of most agricultural facilities is still lower than the reference level (1,000 Bq/$m^3$) recommended by the International Radiation Protection Committee (ICRP), three facilities at one site show higher concentrations than the reference level. The three-month-averaged radon concentration and the instantaneous radon concentration of the underground-air itself ranges 1,228- 5,259 and 3,322-17,900 Bq/$m^3$, respectively, and regional variation is more significant. CONCLUSION: From this results, radon concentration of the underground-air is assumed that it is associated with the geological characteristics and the boring depth of the region located of their.

The investigation of field condition on flood protection of substation and underground power equipment (pad-mounted transformers & switches) (수변전실 및 지중 배전기기의 침수 방지 관련 현장 조사 분석)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.327-331
    • /
    • 2007
  • Inundation of substation and underground power equipment(pad-mounted transformers & switches) breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation of substation and underground power equipment, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we search the damage situation and installation situations. Therefore we propose the necessity of protection of flood at low-lying downtown and low-tying shore. This paper will be used to present a reform proposal of electrical related law about flood protection of existing power equipment.

  • PDF

Radon in the Underground Workplaces; Assessment of the Annual Effective Dose due to Inhaled Radon for the Seoul Subway Station Staffs

  • Song, Myeong-Han;Chang, Byung-Uck;Kim, Yong-Jae;Lee, Hwa-Yong;Heo, Dong-Hey
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.163-166
    • /
    • 2010
  • The effective dose of the Seoul subway staffs due to inhaled radon ($^{222}Rn$) in their workplace was investigated depended on radon concentration exposed at each workplace, and working hours and working types of the staffs. Annual average radon concentrations ranged from 16.5 to 93.0 $Bq{\cdot}m^{-3}$. The staffs commonly spend 2,304 hours in the underground spaces a year. With the radon concentrations and the working hours of the staffs, estimated annual effective doses ranged from 0.23 to 0.73 $mSv{\cdot}y^{-1}$.