• Title/Summary/Keyword: Underground Area

Search Result 1,147, Processing Time 0.03 seconds

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

Analysis of Underpinning Construction Cases for Underground Space Expansion (지하공간 확장을 위한 언더피닝 사례분석)

  • Choi, In-Sub;Rhim, Hong-Chul;Kim, Yang-Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.11-12
    • /
    • 2013
  • It is required to response to the demand for new space due to high density of population and buildings in urban area. In particular, in case of big cities such as Seoul where the lack of new construction site due to the depletion of available space, existing buildings must be demolished for new construction. Utilization of urban underground space can be an alternative to solve for urban space problems. There are applications of underpinning methods using micropiles for existing buildings. Sometimes, the difficulties come from the compact space available for new foundation underneath the existing ones. In this paper, a novel underpinning method is introduced which can solve the space restriction problems underneath existing columns.

  • PDF

Characteristic Analysis of Wireless Channels to Construct Wireless Network Environment in Underground Utility Tunnels (지하공동구 내 무선 네트워크 환경구축을 위한 무선채널 특성 분석)

  • Byung-Jin Lee;Woo-Sug Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.27-34
    • /
    • 2024
  • The direct and indirect damages caused by fires in underground utility tunnels have a great impact on society as a whole, so efforts are needed to prevent and manage them in advance. To this end, research is ongoing to prevent disasters such as fire flooding by applying digital twin technology to underground utility tunnels. A network is required to transmit the sensed signals from each sensor to the platform. In essence, it is necessary to analyze the application of wireless networks in the underground utility tunnel environments because the tunnel lacks the reception range of external wireless communication systems. Within the underground utility tunnels, electromagnetic interference caused by transmission and distribution cables, and diffuse reflection of signals from internal structures, obstacles, and metallic pipes such as water pipes can cause distortion or size reduction of wireless signals. To ensure real-time connectivity for remote surveillance and monitoring tasks through sensing, it is necessary to measure and analyze the wireless coverage in underground utility tunnels. Therefore, in order to build a wireless network environment in the underground utility tunnels. this study minimized the shaded area and measured the actual cavity environment so that there is no problem in connecting to the wireless environment inside the underground utility tunnels. We analyzed the data transmission rate, signal strength, and signal-to-noise ratio for each section of the terrain of the underground utility tunnels. The obtained results provide an appropriate wireless planning approach for installing wireless networks in underground utility tunnels.

Hydraulic Characteristics of Shallow Geology in Dongrae Area, Busan Megacity (부산광역시 동래지역 천부지질의 수리적 특성)

  • Ryu, Sang-Hun;Hamm, Se-Yeong;Jeong, Jae-Hyeong;Han, Suk-Jong;Cheong, Jae-Yeol;Jang, Seong;Kim, Hyoung-Su
    • The Journal of Engineering Geology
    • /
    • v.18 no.1
    • /
    • pp.55-68
    • /
    • 2008
  • At present underground structures such as road tunnels, railway tunnels, underground petroleum storages and radioactive waste storages are being constructed in numerous places in Korea. For the construction of underground structrues, it should be accounted for natural factors (geology, hydrogeology, soil, vegetation, topography and drainage patterns) and human-social factors (land use, urbanization, population, culture and transportation). Especially, hydrogeology should be regarded as an important factor for evaluating the safety of underground structures and their impact to groundwater system around the structures. This study aimed to recognize hydrogeological characteristics of shallow formations in the area from Dongrae crossway to Seo-Dong where 45 boreholes were drilled for the construction of Line-3 subway in Busan Megacity. Slug tests for unsaturated and saturated zones were conducted on 30 boreholes in the study area. From the result of the slug tests, it was identified that average zonal hydraulic conductivity in the unsaturated zone was higher than that in the saturated zone. Besides, the slug test result in the saturated zones may reflect hydraulic properties of the upper most part of the saturated zones.

A Case Study on the Application of 'Conservation First Development Later' Principle for the Development Projects in Jeju Area (제주도 개발사업의 '선보전 후개발' 원칙 적용 사례분석)

  • Cho, Eun-Il;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.113-128
    • /
    • 2014
  • Jeju Special Self-Governing Province has the natural assets resulting in UNESCO World Biosphere Reserve, World Heritage Listed and World Geopark Certification, so the principle of 'Conservation First Development Later' has been set up for the vision of environmental policy to preserve these assets. This case study has been carried out to investigate the realization of the principle of 'Conservation First Development Later' for the development projects performed environmental impact assessment from 1994 to 2012 in Jeju Province, using geographic information systems(GIS). The Jeju Province has its own ordinance to consult and operate an environmental impact assessment(EIA) system. In particular, the conservation area, such as, Absolute/Relative Conservation Area and Underground Water, Ecosystem and View Conservation Zone, has been assigned and managed specially to conserve the natural environment. The 179 projects has been performed EIA for last 18 years in Jeju Province, and then the Absolute Conservation Area has been included in 22 projects and the Relative Conservation Area has been included in 34 projects. However, the 2 projects only have included the Absolute Conservation Area for 7 years after 2005. This result suggests that the application of the principle for the Absolute Conservation Area is strengthened gradually. On the other hand, the 17 projects and the 24 projects have included the Underground Water Conservation Zone assigned grade 1 and 2, respectively, and the number has been increasing after 2004. The results show that it needs to strengthen the application of the principle for this Zone. And the Ecosystem Conservation Zone assigned grade 1 and 2 have been included in 1 project and 9 projects, respectively. It is considered from this result that the principle is realized successfully for the Ecosystem Conservation Zone. In addition, it could be known that the principle is applied well for the View Conservation Zone, in this study.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

Single-particle Characterization of Aerosol Samples Collected at an Underground Shopping Area (단일입자분석법을 이용한 지하상가에서 채취한 실내입자의 특성분석)

  • Kang, Sun-Ei;Hwang, Hee-Jin;Park, Yu-Myung;Kang, Su-Jin;Kim, Hye-Kyung;Ro, Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.594-603
    • /
    • 2008
  • A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis, was applied to characterize four samples collected at an underground shopping area connected to Dongdeamun subway station, in January and May 2006. Based on the analysis of their chemical compositions of the samples, many distinctive particle types are identified and the major chemical species are observed to be soil-derived particles, iron-containing particles. sulfates. nitrates, and carbonaceous particles. which are encountered both in coarse and fine fractions. Carbonaceous particles exist in carbon-rich and organic. Soil derived particles such as aluminosilicates, AlSi/C, $CaCO_3\;and\;SiO_2$ are more frequently encountered in spring samples than winter samples. Nitrate- and sulfate-con taming particles are more frequently encountered in winter samples, and those nitrate- and sulfate-containing particles mostly exist in the chemical forms of $Ca(CO_3,\;NO_3),\;Ca(NO_3,\;SO_4),\;(Na,\;Mg)NO_3\;and\;(Mg,\;Na)(NO_3,\;SO_4)$. Fe-containing particles which came from nearby subway platform are in the range of about 10% relative abundances for all the samples. It is observed that nitrate- and sulfate-containing particles and carbonaceous particles are much more frequently encountered in indoor aerosol samples than in outdoor aerosols, implying that $NO_x,\;SO_x$, and VOCs at the underground shopping area were more partitioned into aerosol phase.

Hydrogeological Characteristics of Seawater Intrusion in the Coastal Area (임해지역 주변에서의 해수침투특성)

  • 김천수;김경수;배대석;송승호
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.61-72
    • /
    • 1997
  • With increasing activities for groundwater withdrawal and for the construction of underground cavern in the coastal areas, the seaward flow of groundwater has been disturbed or even reversed, resulting in seawater intrusion in aquifers. This phenomenon would be attributed to the freshwater contamination and the corrosion of steel materials. The hydrogeological and geochemical investigations have performed to characterize the seawater intrusion into the underground caverns located in the coastal area. Assumimg the inland aquifer as unconfined one, we have found out that the theoretical interface of freshwater-seawater is far different from the pathways identified. In the study site, the main pathways of seawater intrusion into the underground cavern are characterized as the sub-horizontal fractures (zones). The seawater intrusion in granitic terrane would depend mainly on the characteristics of conductive fracture system developed along the coastal area.

  • PDF

A study on the concentration of formaldehyde in public Facilities in Cheon-An area (천안지역 일부 다중이용시설의 포름알데히드 농도에 관한 연구)

  • Jeon, Hye-li;Jo, Su-Yeon;Jo, Hye-Ran;Cho, Tae-Jin;Park, Jong-An;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • This study was conducted at a Terminal, a Parking Lot, an Underground shopping center, a Funeral hall and a Hospital waiting room of Cheon An area in August 2008 to examine the concentration level of HCHO(formaldehyde). The concentration level of the remodeled sites were $39.4\;{\pm}\;12.0\;{\mu}g/m^3$ in the terminal, $32.7\;{\pm}\;7.3\;{\mu}g/m^3$ in the parking, and $97.8\;{\pm}\;29.4\;{\mu}g/m^3$ in the underground shopping center. The underground shopping center had the highest level and followed by the terminal and the parking. On the contrary, the site remodeling had the level of $17.7\;{\pm}\;12.4\;{\mu}g/m^3$ in the funeral hall and $17.9\;{\pm}\;0.6\;{\mu}g/m^3$ in the hospital waiting room. The funeral hall had highest level than that of the hospital waiting room. Both the remodeled sites and the not remodeled site had concentration level of HCHO below the standard level, but it was higher in the remodeled sites. There were no relations among the HCHO, the temperature and the humidity in facilities of Cheon An area.

Detection of cavities in a karst area by means of a 3D electrical resistivity technique (3차원 전기비저항탐사에 의한 카르스트 지역에서의 공동탐지)

  • Park, Sam-Gyu;Kim, Chang-Ryol;Son, Jung-Sul;Yi, Myeong-Jong;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • In this study, we examined the applicability of a 3D electrical resistivity technique for the probing of underground cavities at a field test site in a karst area in Yongweol-ri, Muan-gun, in the south-western part of the Korean peninsula. At the test site, where the ground has subsided in the past, underground cavities are commonly found in the limestone bedrock, which is overlain with alluvial deposits. The limestone cavities at the test site are mostly filled with groundwater and clay; hence, they show levels of electrical resistivity that are significantly lower than those of the surrounding host bedrock. The results of this study demonstrate that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the site, and that our 3D electrical resistivity survey is a very effective tool for detecting and mapping underground cavities in a karst area.