• Title/Summary/Keyword: Uncertainty measurement

Search Result 936, Processing Time 0.025 seconds

The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance (전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

Measurement Range Extension of AC High Voltage using two 200 kV Capacitive Dividers (200 kV 용량형 분압기 2대를 이용한 교류 고전압 측정범위 확장)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Jeong, Jin-Hye;Han, Sang-Ok;Joung, Jong-Man
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • The output voltage value of AC high voltage source has been usually obtained by multiplying low voltage value measured at both terminals of low voltage resistor by the dividing ratio of the high voltage capacitive divider. From the dividing ratio determined of each 200 kV capacitive divider, we have developed step-up method for measuring the output voltage up to 400 kV using two same type of 200 kV capacitive dividers connected in series. The theoretical dividing ratio of 400 kV capacitive dividers connected in series coincides with that of manufacturer's certification within measurement uncertainty. Thus, this developed step-up method makes it possible to extend the range of output voltage from 200 kV to 400 kV. Furthermore, The dividing ratio of divider under test obtained using this step-up method is consistent with that obtained using one 200 kV high voltage divider within corresponding uncertainties.

Application of Geometry-Efficiency Variation Technique to Activity Measurement of $^{204}T1$ for 3-PM Liquid Scintillation Counting

  • Lee Hwa Yong;Seo Ji Suk;Kwak Ji Yeon;Hwang Han-Yull;Lee K. B.;Lee Jong Man;Park Tae Soon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • 3-PM liquid scintillation counting using the geometry-efficiency variation technique has been applied to the activity measurement of $^{204}T1$, which decays to $^{204}Hg\;and\;^{204}Pb\;by\;{\beta}^-$ and E.C., respectively. The TDCR values K have been derived over a wide range, 0.78 < K < 0.97, by displacing the detectors up to 50 mm away from an unquenched liquid scintillation sample $^{204}Tl$. The derived plots of the logic sums of double coincidences $N_D(K)$ very K vary linearly in the observed regions. The fractions of losses due to electron capture decay have been taken into account by employing a PENELOPE Monte Carlo simulation. The calibrated activity is 102.3 kBq at a reference date of July 1st, 2002 (UT) with a combined uncertainty of $0.63\%$. This is consistent with the value determined by means of the CIEMAT/NIST method at KRISS.

Ventilation Measurement with PFT in Three-storied Detached House (PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정)

  • Kim, Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

  • Kang, Ji Hwan;Kim, Yong Doo;Lee, Jinhong;Lee, Sangil
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.202-211
    • /
    • 2021
  • Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • Guo, Hui;Jin, Xin;Huo, Xingkai;Gu, Hanyang;Wu, Haicheng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3888-3896
    • /
    • 2022
  • Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1σ of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65% of relative errors that are less than 5% and 82% of relative errors that are less than 10%.

Comprehensive validation of silicon cross sections

  • Czakoj, Tomas;Kostal, Michal;Simon, Jan;Soltes, Jaroslav;Marecek, Martin;Capote, Roberto
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2717-2724
    • /
    • 2020
  • Silicon, especially silicon in the form of SiO2, is a major component of rocks. Final spent fuel storages, which are being designed, are located in suitable rock formations in the Earth's crust. Reduction of the uncertainty of silicon neutron scattering and capture is needed; improved silicon evaluations have been recently produced by the ORNL/IAEA collaboration within the INDEN project. This paper deals with the nuclear data validation of that evaluation performed at the LR-0 reactor by means of critical experiments and measurement of reaction rates. Large amounts of silicon were used both as pure crystalline silicon and SiO2 sand. The critical moderator level was measured for various core configurations. Reaction rates were determined in the largest core configuration. Simulations of the experimental setup were performed using the MCNP6.2 code. The obtained results show the improvement in silicon cross-sections in the INDEN evaluations compared to existing evaluations in major libraries. The new Thermal Scattering Law for SiO2 published in ENDF/B-VIII.0 additionally reduces the discrepancy between calculation and experiments. However, an unphysical peak is visible in the neutron spectrum in SiO2 obtained by calculation with the new Thermal Scattering Law.

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

CEFR control rod drop transient simulation using RAST-F code system

  • Tuan Quoc Tran;Xingkai Huo;Emil Fridman;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4491-4503
    • /
    • 2023
  • This study aimed to verify and validate the transient simulation capability of the hybrid code system RAST-F for fast reactor analysis. For this purpose, control rod (CR) drop experiments involving eight separate CRs and six CR groups in the China Experimental Fast Reactor (CEFR) start-up tests were utilized to simulate the CR drop transient. The RAST-F numerical solution, including the neutron population, time-dependent reactivity, and CR worth, was compared against the measurement values obtained from two out-of-core detectors. Moreover, the time-dependent reactivity and CR worth from RAST-F were verified against the results obtained by the Monte Carlo code Serpent using continuous energy nuclear data. A code-to-code comparison between Serpent and RAST-F showed good agreement in terms of time-dependent reactivity and CR worth. The discrepancy was less than 160 pcm for reactivity and less than 110 pcm for CR worth. RAST-F solution was almost identical to the measurement data in terms of neutron population and reactivity. All the calculated CR worth results agreed with experimental results within two standard deviations of experimental uncertainty for all CRs and CR groups. This work demonstrates that the RAST-F code system can be a potential tool for analyzing time-dependent phenomena in fast reactors.

The Fuzzy QFD Approach to Importance the Public Sector Information Performance Measurement Category (퍼지 QFD를 활용한 공공부문 정보화 성과 측정범주 중요도 도출)

  • Oh, Jin-Seok;Song, Young-Il
    • Information Systems Review
    • /
    • v.12 no.2
    • /
    • pp.189-203
    • /
    • 2010
  • Is presenting guidance of information performance measurement as government PRM version 2.0 these common reference models in public sector. Government PRM is consisted of assessment classification system and standard line of sight and performance management standard form. Through this, is sorting performance element and define cause-and effect. Government PRM is supplying measurement categories at assessment classification system, but relative importance for application standard by measurement categories is not presenting. In this study, importance for government PRM's measurement categories been applying by commonness Test of information performance measurement of public sector wishes to deduce estimation and priority. Research model used Fuzzy QFD, and designed so that can reflect well PRM's development purpose. I applied Fuzzy AHP and FPP method that graft together fuzzy theory to minimize uncertainty and ambiguity in that expert opinion. Is drawn to element that "Standard model offer for information department and management" is the most important in government PRM's development purpose. "Quality of service" is showing the highest priority in customer results in measurement category. Importance for government PRM's measurement categories can offer common valuation basis in government and public institution. Hereafter if examine closely quantitative cause-and effect for structure model of measurement classification system when study government PRM more objective and efficient reference model become.