• Title/Summary/Keyword: Uncertainty measurement

Search Result 930, Processing Time 0.026 seconds

An Implementation of Time Code Generator for Sending Real Time Information (실 시각정보 전송을 위한 시각코드발생기 제작)

  • Kim, Young-Beom;Park, Young-Tae;Lee, Young-Kyu
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.6 no.3
    • /
    • pp.9-13
    • /
    • 2007
  • In this paper, we propose a system that can be used to provide the national standard time for the general public with ease by using the self-implemented independent time-code generator for transmitting standard time information through both the wired and the wireless networks. The newly proposed time code is different from conventional methods in the point that it has a structural advantage of having an ability of obtaining reliable data by repeatedly transmitting the same information. We observe that it is sufficiently possible to transmit the time information with a microsecond level because measurement result shows that the system uncertainty is about few nanosecond of time-error fluctuation through the self characteristic measurement of total system including the time-code generator and decoder system receiving time-information.

  • PDF

Development and Its Properties of Resistance Standards for Using Alternative Current (교류저항 표준기 제작과 그 특성)

  • Kim, Han-Jun;Lee, Sang-Hwa;Kang, Jeon-Hong;Yu, Kwang-Min;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.267-268
    • /
    • 2009
  • Resistance standards from 1 ${\Omega}$ to 100 $k{\Omega}$, with calculable frequency dependencies of up to 1 MHz, have been developed for the calibration of commercial inductance-capacitance-resistance (LCR) meters and impedance analyzers. The resistors are designed on the basis of single bifilar loops. The typical resistance change from dc to 1 MHz is from 200 to $800\;{\mu}{\Omega}/{\Omega}$. According to the measurement results, the frequency dependencies of the resistors are severaltimes lower than the measurement uncertainty of commercial LCR meters.

  • PDF

Measurement of Psychological Work Environment for Technology Innovation (기술혁신을 촉진하는 심리적 작업환경의 측정-척도의 신뢰성과 타당성 검증을 중심으로-)

  • 한인수;박경환
    • Journal of Technology Innovation
    • /
    • v.6 no.1
    • /
    • pp.163-186
    • /
    • 1998
  • The psychological work environments which facilitate technology innovations in organizations are divided into two dimensions of supportive work environments and uncertain work environments. The measurement variables have significant reliability. And the confirmatory factor analysis confirm the construct validity of two dimensional work environments. Two work environments have the significant effects on motivations to the technology innovations. So, simple and hierarchical regression analyses confirm criterion-related validity. Therefore, Both of the uncertain work environments(uncertainty of external-organizational environments and tasks) and the two important work environments(supporting idea, resource supply, job autonomy) are the two important psychological work environments which indicate technology innovations in organizations. Measures for innovative psychological work environments are provided.

  • PDF

Orthogonality Measurement of Square Plane Mirrors for Laser Interferometry (레이저 간섭계의 직각 평면거울에 대한 직각도 오차 측정)

  • 김태호;김승우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.169-179
    • /
    • 1998
  • Plane mirror type laser interferometers are popularly being used in many modern ultraprecision machines, as they can perform simultaneous measurements of multiple axis positions with nanometer resolution capabilities. One important issue in this application of laser interferometers is to provide a good level of alignment between the reflecting mirrors and the laser beams so that measurement errors due to undesirable coupling effects can be avoided in multiple axis measurements In this investigation, a thorough metrological analysis is given to develop an suitable mathematical model for a precision x-y stage in which the orthogonality misalignment between the reflecting mirrors significantly affects overall x-y mea-surement results. Then a noble calibration method is suggested in which two-dimensional displacement sensors of moire gratings of concentric circles are used to realize the reversal principle of orthogonality evaluation in situ. Finally, actual experimental results are discussed to verify that the suggested method can effectively calibrate the orthogonality error with an uncertainty of 0.2667 arcsec.

  • PDF

Analysis of Discrete-Time Disturbance Observer for Second-Order Systems (2차 시스템에 대한 이산시간 외란 관측기의 분석)

  • 양광진;최영진;정완균
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.425-434
    • /
    • 2003
  • The disturbance observer(DOB) has been widely used in high speed and high precision motion control applications and the characteristics of DOB have been investigated in depth. Though most of DOB's have been implemented as the discrete-time form in digital devices, we are still short of the researches on discrete-time DOB (DDOB) in spite of rich references on continuous-time DOB. In this paper, we discuss about the disturbance rejection property and measurement noise effect of discrete-time DOB. Especially, we will focus on revealing the role of sampling time in designing the discrete-time DOB and show the validity of analysis through simulations and experiments for optical disk drive systems.

Performance Evaluation of the Samcheonpo Small-Hydro Power Plant (삼천포 해양소수력 성능평가)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kang, Geum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.617-620
    • /
    • 2007
  • The performance evaluation of the Samcheonpo small-hydropower plant constructed on the October 25th,2006, was carried out focused on the turbine and generator efficiency analysis by using the measurement data. The unreasonable and unrealistic efficiency results are occurred in some periods because of the data variability, uncertainty, and measurement errors and mistakes. Whereas, the big mismatch is the tidal elevation predicted in the design processes. The difference between the measured and estimated tidal elevation is obvious during the low water period. It should be considered and checked in depth on the efficiency analysis of the planned and constructing small-hydro power plants in other coastal areas.

  • PDF

The Development of an accurate, automated measurement system of high value resistors (고저항 정밀측정용 자동화 시스템의 제작)

  • Ryu, Je-Cheon;Kang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.806-808
    • /
    • 1999
  • An automatic measurement system of high value resistance standards($10M{\Omega}$ and $1G{\Omega}$) was developed. A system has been assembled with programmable do calibrators in two of the arms. An electrometer is used to measure the difference in currents flowing through the remaining two arms of the bridge consisting of unknown and standard resistors. Type A standard uncertainty was 2ppm in the $10M{\Omega}$, 1 ppm in the $1G{\Omega}$.

  • PDF

Error Analysis of Free-Form Artifact using 3D Measurement Data (3차원 측정 데이터를 이용한 자유곡면 가공물의 오차해석)

  • 김성돈;이성근;양승한;이재종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.439-442
    • /
    • 2001
  • The Accuracy of a free-form artifact is affected by machine tool errors, machining process errors, environmental causes and other uncertainty. This paper deals with methodological approach about machine tool errors that are defined the relationship between CMM and OMM inspections of the free-form artifact. In order to analyze the measurement data, Reverse engineering was used. In other words, Surface of Free-Form Artifact is generated by NURBS surface approximation method. Finally, Volumetric error map is made to compare surface of CMM data with that of OMM data.

  • PDF

A Study on the Ball-Bar Artifact for the Volumetric Error Calibration of Machine Tools (Machine Tools 공간오차 분석을 위한 Bal1-bar Artifact 연구)

  • Lee, Eung-Suk;Koo, Sang-Seo;Park, Dal-Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.986-991
    • /
    • 2004
  • For volumetric error measurement and calibration for machine tools, manufacturing machine or coordinate measuring machine (CMM), are studied using a Ball-bar artifact. A design of the Ball-bar is suggested manufactured by Invar, which is a low thermal expansion material, and precision steel balls. The uncertainty for the artifact method is discussed. A method of the Ball-bar artifact for obtaining 3-D position errors in CMM is proposed. The method of error vector measurement is shown using the Ball-bar artifact. Finally, the volumetric error is calculated from the error vectors and it can be used for Pitch error compensation in conventional NC machine and 3-D position Error map for calibration of NC machine tools.

Introduction and application of three sound visualization systems (3가지 음장가시화 시스템의 소개와 적용 예)

  • 김양한;남경욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1197-1202
    • /
    • 2001
  • Near-field acoustic holography is a powerful tool to visualize sound sources. This method requires pressure measurement at many points for a good hologram. Thus one has to measure carefully so that errors due to the uncertainty of position, sensor mismatch, and so on are reduced. A method to solve this problem is to use a well-designed measurement system. This paper introduces a sound visualization system at center for noise and vibration control (NOVIC), KAIST, and addresses the advantages in terms of the error reduction. The system consists of array microphones, array jigs, a system to control the position and the velocity of the jigs, a data acquisition system, and a monitoring system. This paper also shows some sound visualization results when the system is applied to a speaker and a computer. The results verifies that the sound visualization system is useful for identifying sound sources.

  • PDF