• 제목/요약/키워드: Uncertainty measurement

검색결과 931건 처리시간 0.029초

필터 기반 블랙카본 측정에서의 보정과 불확실성에 대한 고찰 (Corrections and Artifacts Regarding Filter-based Measurements of Black Carbon)

  • 이정훈
    • 한국대기환경학회지
    • /
    • 제34권4호
    • /
    • pp.610-615
    • /
    • 2018
  • A filter-based optical technique is one of the representative ways for the measurement and quantification of black carbon (BC). Since the filter-based technique adopts a simple principle, it is easy to put into practical use and instrumental products have already been commercialized. In this study, however, the absorption coefficients of BC after the correction process was estimated to be approximately 3 times lower than those before the correction process. In addition, the difference between before and after corrections was also evident for the trend of increasing and decreasing absorption coefficient. When BC concentration is low, uncertainty may increase regardless of corrections due to the artifacts of filter. In this sense, techniques without using a filter are required, and uncertainties will be minimized if these techniques are used to further complement the filter-based black carbon measurements. Finally, this study is believed to help understand the uncertainty and correction of filter-based black carbon measurements.

부하변동에 강인한 DC/DC 승압 컨버터의 잔류 추정 (Robust Current Estimation of DC/DC Boost Converter against Load Variation)

  • 김인혁;정구종;손영익
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2038-2040
    • /
    • 2009
  • This paper studies the state estimation problem for the current of DC/DC boost converters with parasitic inductor resistance. The parasitic resistance increases the system uncertainty when the output load variation occurs. In order to enhance the observation performance of the Luenberger observer this paper includes the integral of the estimation error signal to the estimation algorithm. By using the proposed PI observer the converter current signal is successfully reconstructed with the voltage measurement regardless of the load uncertainty. Computer simulation has been carried out by using Simulink/Sim Power System. Simulation results show the proposed method maintains robust estimation performance against the model uncertainty.

통신케이블 차폐시험방법의 유효성 확인 및 측정불확도 추정 (Validation and Measurement Uncertainty Estimation in the Testing Method of Cable-harness Shielding Effectiveness)

  • 김종상;조남호
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권1호
    • /
    • pp.8-19
    • /
    • 2002
  • 시험기관은 표준화되지 않은 시험방법. 해당기관이 설계/개발한 방법 등에 의한 시험을 수행할 경우 방법의 유효성이 확인되어야만 사용할 수 있으며, 또한 측정값에 대한 불확도(Uncertainty)의 추정이 요구되고 있다. 따라서 케이블-하네스의 EMI 차폐효과시험방법에 대한 측정정밀도를 통계적 분석 방법 에 의거 검토하여 유효성을 확인하는 방법을 제시하고 시험결과에 대한 측정불확도를 추정하는 방법을 제시하였다.

  • PDF

삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement)

  • 이혁교;주지영;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

빅 데이터의 자율 속성 감축을 위한 확장된 정보 엔트로피 기반 상관척도 (Extended Information Entropy via Correlation for Autonomous Attribute Reduction of BigData)

  • 박인규
    • 한국게임학회 논문지
    • /
    • 제18권1호
    • /
    • pp.105-114
    • /
    • 2018
  • 고객 유형 분석에 쓰이는 다양한 데이터 분석 방법은 고객들을 위한 맞춤형 콘텐츠를 기획하고, 보다 편리한 서비스를 제공하기 위하여 고객들의 유형과 특성을 정확히 파악하는 것이 매우 중요하다. 본 논문에서는 정보의 손실을 줄이기 위한 일환으로 정보 엔트로피를 확장하여 속성의 불확실성을 이용한 k-modes 군집분석 알고리즘을 제안한다. 따라서 속성에 대한 유사도의 측정은 두 가지의 측면에서 고려되어진다. 하나는 각 분할의 중심에 대한 각 속성간의 불확실성을 측정하는 것이고, 다른 하나는 각 속성이 가지는 불확실성에 대한 확률적 분포에 대한 불확실성을 측정하는 것이다. 특히 속성내의 불확실성은 속성의 엔트로피를 확률적 정보로 변환하여 불확실성을 측정하기 때문에 최종적인 불확실성은 비확률적인 척도와 확률적인 척도에서 고려되어 진다. 여러 실험과 척도를 통하여 제안한 알고리즘의 정확도가 최적의 초기치를 기반으로 군집분석을 수행한 결과에 준수함을 보인다.

전압변성기용 부담특성 정밀분석용 자동평가시스템의 개발 (Development of an Automatic Evaluation System for the Precision Analysis of Potential Transformer Burden Characteristics)

  • 권성원;김문석;정재갑;이성하;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.457-464
    • /
    • 2005
  • Both ratio error and phase angle error in potential transformer(PT) are critically affected by used burden, connected in parallel to the secondary terminal of the PT. Thus precise measurement of burden value is very important for the evaluation of PT An automatic measurement system has been developed for the measurement of burden value and power factor of a burden. The ac voltage, current and power of the burden are measured precisely, and the burden value and power factor were calculated from these measured values. The resistance and inductance values of the tested burden are also calculated. The overall measurement uncertainties are calculated and reported with the burden value and power factor. The best measurement uncertainty for the burden measurement with the developed automatic measurement system was estimated to be 0.5 $\%$.

PIV를 이용한 3차원 속도계측에 의한 유동장의 공간 및 벽면압력 분포 추정에 관한연구 (A Study on Estimation of inner and Wall Pressure Distribution by 3-Dimensional velocity Measurement using PIV)

  • 이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.468-480
    • /
    • 1998
  • A flow measurement system which is able to measure the instantaneous three-dimensional velocity components and the pressure distribution of fluid flows is developed using a digital image processing system and the stereoscopic photogrammetry. This system consists of two TV cameras a digital image processor and a 32-bit microcomputer. The capability of the developed system is verified by a preliminary test in which three-dimensional displancements of moving particles arranged on a rotating plate are tracked automatically. The constructed system is through the measurement and spatial pressure distribution is also obtained. The measurement uncertainty of this system is evaluated quantitatively. The present technique is applicable to the measurement of an unsteady fluid phenomenon especially to the measurement of three-dimensional velocity field of a complex flow.

  • PDF

장애아 어머니의 불확실성, 사회적 지지 및 무력감 (Uncertainty, Social Support & Powerlessness in Mothers of Handicapped Children)

  • 박은숙;오원옥
    • Child Health Nursing Research
    • /
    • 제5권2호
    • /
    • pp.151-166
    • /
    • 1999
  • The purposes of this study were to measure the degree of perceived uncertainty, social support & powerlessness, to examine the relationship between the perceived uncertainty, social support & powerlessness and then to find the predictors of powerlessness in mother's of handicapped children. The subjects of this study consist of 102 mothers of handicapped children, registered at rehabilitation & handicapped children school. Data was collected from September 1998 to March 1999. The tools used in this study were Mishel's the Parents' Perception of Uncertainty Scale (28 item, 4 likert scale), Miller's Powerlessness measurement Scale(28 itewt 4 likert scale) & Cohen's Interpersonal Support Evaluation List (40 items, 4 likert scale). Data was analyzed by t-test, ANOVA, Duncan comparison, Pearson Correlation coefficient & Stepwise multiple regression Results of this study are summarized as follows : 1. Mothers perceived their uncertainty to be slightly high(Mn 2.50). The degree of perceived uncertainty by the four components were followed as : lack of clarity(2.69), unpredictability(2.56), ambiguity(2.56) & lack of information(2.46). The degree of perceived uncertainty of the mothers of handicapped children revealed to be influenced significantly by age of children, admission experience, disability types of children. 2. The degree of mothers' powerlessness was measured to be slightly high(Mn 2.14). The degree of perceived powerlessness of the mothers with handicapped children revealed to be influenced significantly by age of children, duration of illness admission experience,8E marital status of the mothers. 3. Mothers perceived their social support to be slightly high(Mn 2.71). The degree of perceived social support revealed to be influenced significantly by sex of children, married state of mothers. 4. Mothers' uncertainty was related positively to the mothers' powerlessness(r=.33, p=.0008). And also mothers' powerlessness was related inversely to social support(r=-.50, p=.0001). But, mothers' uncertainty was not related to social support significantly. 5. To analyze the variables which affect powerlessness, stepwise regression was implemented. As a result, about 61% of the powerlessness were explained by social support, marital status of the mothers and perceived uncertainty. Based upon these results, it is recommended that the nurses, who are caring handicapped children and their families, provide various support programs for them to overcome their difficulties. Also programs which decrease the uncertainty & powerlessness used social support multidimensionally & individually are recommended to be developed.

  • PDF

터보분자펌프(TMP) 배기속도 측정에 관한 고찰 (Study on the Measurement of TMP Pumping Speed)

  • 강상백;신진현;차덕준;고득용;정완섭;임종연
    • 한국진공학회지
    • /
    • 제19권4호
    • /
    • pp.249-255
    • /
    • 2010
  • 터보분자펌프(TMP)의 특성평가는 ISO, PNEUROP, DIN, JIS, AVS 등 세계 여러 나라의 표준제정기구에서 제정한 국제규격에 그 근거를 두고 있다. 한국표준과학연구원에서는 이러한 국제규격에 기반을 둔 터보분자펌프의 특성평가시스템을 자체 설계/제작하여 그 신뢰성을 확인하기 위해 개발품 및 상용품의 평가에 주력하고 있다. 터보분자펌프의 배기속도 측정방법으로서 기체흐름 영역에 따른 throughput method와 orifice method를 적용하고 있으나 측정게이지, 유량계 및 orifice conductance의 불확도 등 실질적으로 정확한 배기속도를 제시하기 위한 조건들의 제약 때문에 많은 측정오차를 포함하고 있다고 볼 수 있다. 이러한 배기속도의 측정오차를 줄이기 위한 하나의 고찰로서 본 논문에서는 $10^{-1}$ Pa-L/s 영역까지의 유량 주입범위를 가지는 기 구축된 정적법을 이용한 유량주입에 기반을 둔 throughput method를 이용하여 1000 L/s TMP의 측정 능력을 검증하고자 한다. 또한 분자류 영역인 orifice method를 사용할 경우 고진공영역, 미세유량 주입영역으로 진입할수록 커질 수밖에 없는 배기속도 측정 불확도를 최소화시키기 위해 검증된 유량을 이용한 conductance 값을 제시하여, 기 언급한 두 가지 배기 속도 측정 방법의 연속성을 유지하기 위한 실험적인 방법론을 제기하고자 한다.

대전류 분류기 저항의 정밀측정 (Precise Measurement of High Current Shunt Resistance)

  • 김규태;한권수;권성원;김문석;정주영;김익수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.403-406
    • /
    • 2005
  • Precise measurement of extremely low resistance shunt is important for characterization and calibration of high current instruments. We tested resistance measurement method for extremely high current shunt (up to 140 kA), where resistance is determined by precise measurement of voltage drop at 10 A test current in the frequency range of 40 Hz to 10 kHz. For the extremely low ac voltage to be precisely measured, a verification of the measurement method was also carried, where the inherent noise is systematically evaluated. The measurement uncertainty was estimated to be $1\;\%\;at\;95\;\%$ confidence level (k=2) for about 50 $\mu\Omega$.