• 제목/요약/키워드: Unbalanced distribution system

검색결과 117건 처리시간 0.026초

분산형전원이 연계된 배전계통의 전압조정에 관한 연구 (Voltage Regulation Method at the Power Distribution System interconnected with DSG System)

  • 최준호;추동욱;김재철;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.250-252
    • /
    • 1997
  • This paper deals with voltage regulation at the power Distribution system interconnected with DSG. Modern distribution substation adopt LDC method as the voltage regulation method to deliver suitable voltages to many customers. However, the operations of DSG interconnected with distribution system, the customers' voltage violate the permissible voltage limits. Therefore, to deliver suitable voltage to many customers at the distribution substation, an advanced voltage regulation method is required. In this paper, the on line realtime MLDC (Multiple Line Drop compensation) method, considered daedband and hysterical tap changing of the ULTC, is proposed. The result from a simulation study shows that the proposed method can be practical applications for the voltage regulation at the distribution system interconnected with DSG and unbalanced load pattern among feeders.

  • PDF

BLDC 전동기의 전자기적 불평형력을 고려한 편심 회전자의 동적 거동 해석 (Dynamic Behavior Analysis of an Eccentric Rotor with Unbalanced Magnetic Forces in BLDC Motors)

  • 김태종;황상문;박노길
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.604-610
    • /
    • 1999
  • Vibration of a rotor-bearing system driven by an electric motor is a coupled phenomenon between mechanical characteristics and magnetic origins through the air-gap. With the advent of new high-energy magnets together with high precision motor applications, magnetic sources of vibration are becoming more serious. This paper investigates the transient whirl responses of a rotor system with purely mechanical origins and compares it with that of magnetically coupled origins. A perturbation method is applied to model the magnetic field associated with rotor eccentricity. Electromagnetic forces are obtained by the Maxwell stress method, which utilizes the analytical expression of radial flux density distribution. The FEM was applied to a rotor-motor system to illustrate magnetically coupled effects in rotor dynamics. Results show that magnetically coupled sources significantly affect the vibration of the rotor-motor system.

  • PDF

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

배전자동화 시스템의 단말장치(FRTU)로부터 취득되는 데이터를 이용한 방사상 배전계통 조류계산 방법에 관한 연구 (A Study on Power Flow Method of Radial Distribution System using a measured data from FRTU in Distribution Automation System)

  • 김형승;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.286-287
    • /
    • 2015
  • Currently, Studies on improving the reliability of power supply is becoming an important issue because of the increase in demand of the electric power system. Therefore necessity of automation in distribution system is increasing day by day. However, a measured voltage data from FRTU of distribution automation system is incorrect because of installation space limits. Therefore there is a need of system analysis method by considering the characteristics of the distribution system. For a distribution system, applying the power flow method of transmission system has some problems, as distribution is radial system and it has unbalanced load. Therefore power flow by considering the characteristics of the distribution system have been studied. Existing power flow analysis of the distribution system has different methods like direct analysis method, backward/forward sweep method, modified method of newton raphson etc. In this paper, an improved power flow analysis method based on backward/forward sweep method is proposed in order to efficiently operate the distribution automation system. The proposed method of power flow has been verified through the result of case study.

  • PDF

Power Factor Improvement of Distribution System with EV Chargers based on SMC Method for SVC

  • Farkoush, Saeid Gholami;Kim, Chang-Hwan;Jung, Ho-Chul;Lee, Sanghyuk;Theera-Umpon, Nipon;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1340-1347
    • /
    • 2017
  • Utilization of Electric Vehicles (EVs) have been growing popularity in recent years due to increment in fuel price and lack of natural resources. Random unexpected charging by home EV charger in distribution is predicted in the future. The power quality problems such as fluctuation of power factor in a residential distribution network was explored with random EV chargers. This paper proposes a high-performance nonlinear sliding mode controller (SMC) for an EV charging system to compensate voltage distortions and to enhance the power factor against the unbalanced EV chargers. For the verification of the proposed scheme, MATLAB-Simulink simulations are performed on 22.9-kV grid. The results show that the proposed scheme can improve the power factor of a smart grid due to the EV chargers on the grid.

한전 실 배전계통 모델을 이용한 1단 장주 중성선 전류 계산 (Neutral Current Calculation of the One Step Type Pole using KEPCO's Distribution System)

  • 서훈철;박건우;김철환;정창수;유연표;임용훈;설일호
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.35-40
    • /
    • 2007
  • The one step type and two step type pole are used in distribution line. If the three phases are not balanced, the communication line can be damaged by induced voltage. This paper calculates the neutral current using KEPCO's distribution system model which is only composed by one step type pole. The used system model is modelled by using ATPDraw and the neutral current is calculated by using EMTP/MODELS. Many cases for abstracting the neutral current characteristics in KEPCO's distribution system are simulated and analyzed.

Source Current Control Strategy of Active Power Filters for Unbalanced Load Compensation in Three-Phase Four-Wire Distribution Networks

  • Wang, Lei;Han, Xiaoqing;Meng, Runquan;Ren, Chunguang;Wang, Qi;Zhang, Baifu
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1545-1554
    • /
    • 2018
  • This paper proposes a modified control strategy to improve the performance of three-phase four-leg shunt active power filters (APFs) for the compensation of three phase unbalanced loads. Unbalanced current cannot be obtained accurately by a harmonic detector due to the lower frequency. The proposed control strategy eliminates conventional harmonic detectors by directly regulating the source current. Therefore, the computational complexity is greatly reduced and the performance of the APF is improved. A mathematic model has been developed based on the source currents. The corresponding controllers have been designed based on the sinusoidal internal model principle. The proposed control strategy can guarantee excellent compensation performance and stable operation after an extreme disturbance such as a short circuit fault. In addition, the proposed technique can selectively compensate specific harmonics. A 50kVA prototype APF is implemented in the laboratory to validate the feasibility and performance of the proposed control strategy.

배전 SCADA 기능을 이용한 고장타입.고장위치 진단 전문가 시스템 (An Expery System for the Diagnosis of the Fault Type and Fault Loaction In the Distribution SCADA System)

  • 고윤석;신덕호;신현용;이기서
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1417-1423
    • /
    • 1999
  • Distribution system can experience the diverse events instantly and permanently. Also, it can experience high impedance fault or line drop under unbalanced situation, Accordingly, it is difficulty to identify the fault location because that data collected from distribution SCADA system may include uncertainty. This paper proposes an expert system, which can infer the faulted location the quickly and exactly for the diverse events in the distribution system. The expert system utilizes distribution SCADA function and collected data, especially, the monitoring mechanism for the normal open position switches is adopted newly in order to recognize the fault type exactly. Also, automated fault location diagnosis strategy is developed in order to minimize the spreading effect of fault obtained from the error of the system operator. The proposed strategy is implemented in C language. Especially, in order to prove the effectiveness of proposed expert system, the several scenario is simulated for the given model system. The real feeders are selected as model system for the simulation.

  • PDF

PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교 (The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA)

  • 신호전;김지호;강갑석;김재철;이향범
    • 전기학회논문지P
    • /
    • 제62권2호
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

자기회로 불평형을 고려한 가동 코일형 리니어 진동 엑츄에이터의 운전특성 개선 (Performance Improvement of Moving Coil Type Linear Oscillatory Actuator Considering Asymmetric Magnetic Circuit)

  • 김덕현;엄상준;강규홍;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권11호
    • /
    • pp.713-719
    • /
    • 2000
  • This paper presents an approach toward improving the performance of Moving Coil Type Linear Oscillatory Actuator (MC-LOA) with the application of Finite Element Method (FEM) to a simple control system. MC-LOA has an unbalanced magnetic circuit due to its asymmetric structure and there is a different flux distribution on the air-gap along the current direction. The interaction driven by two fluxes between the Permanent Magnet (PM) and the current causes the unbalanced thrust and interferes with the proper oscillation of MC-LOA. In order to solve the above problems and improve the driving performance, it is necessary to analyze the rate of the unbalanced thrust according to the current direction by using FEM. Then, the analysis results are used to determine the input currents for both directions. Controlling the input currents can be easily achieved by a simple control system, such as Pulse Width Modulation (PWM), without complex units. The validity of the approach is verified by the experimental results.

  • PDF