초음파를 이용한 기체 유동장내 분진 모니터링 (Particle Monitoring Using Ultrasound in the Gas Flow)

  • 장경영;김주철;김홍준;황원호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.

초음파 의료영상에서 컴파운딩 기법을 이용한 초음파의 평균 음속도의 측정과 음속도 영상의 구현 (Measurement of the Average Speed of Ultrasound and Implementation of Its Imaging Using Compounding Technique in Medical Ultrasound Imaging)

  • 정목근;권성재;최민주
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.233-240
    • /
    • 2009
  • Using a spatial compound imaging technique in a medical ultrasound imaging system, the average speed of sound in a medium of interest is measured, and imaging of its distribution is implemented. When the brightness reaches the highest level in an ultrasonic image obtained as the speed of sound used in focusing is varied, it turns out that the focusing has been accomplished satisfactorily and that the speed of sound which has been adopted becomes the sought-after average speed of sound. Because spatial compound imaging provides many different views of the same object, the adverse effect of erroneous speed-of-sound estimation tends to be more severe in compound imaging than in plain B-mode imaging. Thus, in compound imaging, the average speed of sound even in the case of speckled images can be accurately estimated by observing the brightness change due to different speeds of sound employed. Using this new method that offers spatial diversity, we can construct an image of the speed of sound distribution in a phantom embedded with a 10-mm diameter plastic cylinder whose speed of sound is different from that of the background. The speed of sound in the cylinder is found to be different from that of the surrounding medium.

3차원 프린팅 적층가공 방식에서 매질 내부 충전이 초음파 속도와 감쇠에 미치는 영향 (Effects on Changes of the Speed of Sound and the Broadband Ultrasound Attenuation on the Medium's Infilling in Additive Manufacturing Method of 3D Printing)

  • 성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.53-60
    • /
    • 2018
  • The purpose of this study was investigating the effect of 3D printing technology that changes the speed of sound (SOS) and the broadband ultrasound attenuation (BUA) by controlling the density of the media phantom. We used 3D printers which called additive manufacturing (AM) by using material with polylactic acid (PLA). The inside of the medium phantom was filled crossly with 100%, 90%, 80%, 70%, 60%, and 50% of the material. The ultrasonic instrument measured the SOS and the BUA using a 0.55 MHz ultrasound output in opposing mode with a pair of transducers. As a result, the density of the medium phantoms with the SOS showed very high correlation (r = 0.944), but the SOS showed very low correlation (r = 0.500). It is expecting that the manufacturing and measurement method of the medium phantom using 3D printing technology will be used as basic data for ultrasonic bone mineral density.

완관절 초음파통과속도를 이용한 골연령 측정값과 X-ray영상을 이용한 골연령 측정값의 비교 (A study on growth and development of children by Ultrasound transonic velocity of inferior radiocarpal joint)

  • 고덕재;유한정;이진용;김덕곤;윤경희
    • 대한한방소아과학회지
    • /
    • 제19권2호
    • /
    • pp.165-174
    • /
    • 2005
  • Objectives : The purpose of this study was to suggest a new method for measurement of children's growth development Ultrasound transonic velocity of inferior radiocarpal joint has some advantages that it is harmless to human body and apply a new analysis algorithm, it can be used for the diagnosis of bone age. Methods: This clinical study have been carried out with the 117 case(male 68, female 49) of the children aged 5 to 16 years old who visited in Department of Pediatrics, ${\bigcirc}{\bigcirc}$ university Oriental Hospital. Bone maturity is measured by Ultrasound transonic velocity and X-ray image of growth plate in inferior radiocarpal joint. This study were designed to investigate the relationship of the bone age by Ultrasound transonic velocity and X-ray image. Result & Conclusion : The maturity of growth plate of inferior radiocarpal joint was correlated with age, height, weight, BMI in this study(P<0.001). The Ultrasound transonic velocity of inferior radiocarpal joint are sufficient diagnostic worth as an index to predict bone maturity.

  • PDF

Comparison of real-time ultrasound imaging for manual lymphatic drainage on breast cancer-related lymphedema in individuals with breast cancer: a preliminary study

  • Seo, Dongkwon;Lee, Seungwon;Choi, Wonjae
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권1호
    • /
    • pp.43-48
    • /
    • 2020
  • Objective: Breast cancer-related lymphedema (BCRL) is a major sequela after surgery or radiotherarpy for breast cancer. Manual lymphatic drainage (MLD) is designed to reduce lymph swelling by facilitating lymphatic drainage. This study attempted to determine the histologic changes in the skin and subcutaneous layer, and the immediate effect of MLD in decreasing lymphedema using ultrasound imaging, which is the method used most commonly to eliminate BCRL. Design: A single-group experimental study. Methods: Five subjects who were diagnosed with hemiparetic upper extremity lymphedema more than six months after breast cancer surgery participated in the study. MLD was performed for 60 minutes in the order of the thorax, breast, axilla, and upper arm of the affected side. In order to determine the effect of MLD, ultrasound imaging and limb volume were assessed. Two measurement tools were used for asessing lymphedema thickness among the pretest, posttest, and 30-minute follow-up period. Results: Significant diferences in ultrasound imaging and upper limb volume were found between the affected side and non-affected side (p<0.05). On the affected side, although ultrasound imaging showed a significant decrease after MLD (p<0.05), there were no significant difference in upper limb volume when compared to the baseline. Conclusions: In this study, a significant decrease in lymphedema by MLD was demonstrated by ultrasound imaging, which is considered to be more useful in assessing histological changes than limb volume measurements. Further research on the protocol for eliminating lymphedema will be needed.

ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구 (A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom)

  • 박지혜;허영철;김연민;한동균
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.463-472
    • /
    • 2021
  • 산부인과 초음파 검사에서 골반 장기를 관찰하기 위해 고주파수의 경질 탐촉자를 이용한 검사의 수요가 증가하고 있다. 하지만 임상에서는 경질 탐촉자의 정도관리가 제대로 시행되고 있지 않으며 평가 기준이 확립되지 않은 실정이다. 따라서 현재 사용되고 있는 산부인과용 초음파 장치 20대를 대상으로 58개의 경질 탐촉자와 20개의 곡면 탐촉자를 ATS-539 표준팬텀에 적용하여 각각의 영상을 획득 한 후 정량과 정성적으로 측정하였다. 정량측정은 종측정, 횡측정, 국소영역, 정성측정은 불응영역, 축방향/외측방향 분해능, 예민도, 기능적 해상도, 회색조와 동적범위를 실시하였다. 정량적 통계 분석 결과 횡측정, 국소영역에서 두 탐촉자 간 유의한 차이가 있었으며,(p<0.05) 정성적 비교 분석 결과 예민도, 기능적 해상도에서 차이점을 확인 할 수 있었다. 이는 탐촉자 간 갖는 주파수의 차이와 탐촉자의 주사 기하학의 차이로 발생 한 것으로 사료된다. 위와 같은 실험 결과를 토대로 횡 거리 평가의 허용 범위는 10%(±8 mm)으로 상향, 예민도의 허용 범위는 삼사분위(75%) 수준인 12 cm깊이인 6개까지 관찰, 기능적 해상도의 평가의 허용 범위는 삼사분위(75%) 수준인 6개(12cm), 6개(12cm), 11개(11cm), 9개(9cm), 6개(6cm)까지 관찰, 회색조와 동적범위의 표적의 깊이를 4cm 깊이의 50%인 2 cm 깊이에서도 측정이 가능하게 표적을 추가하는 것이 타당하다고 사료된다. 연구 결과를 통해 산부인과용 경질 탐촉자의 정도관리 평가 기준을 제시하였으며 본 연구가 향후 경질 탐촉자 전용 팬텀 제작을 위한 기초자료로 활용될 것으로 기대한다.

Doppler ultrasound를 이용한 교정적 치아 이동 시 치수 혈류량의 변화의 측정- 예비실험 (Changes in pulpal blood flow during orthodontic tooth movement studied by Doppler ultrasound)

  • 임경섭;배영민;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권6호
    • /
    • pp.372-382
    • /
    • 2009
  • 교정적 치아 이동 시 지속되는 압력에 의해 혈류변화가 발생하게 되며, 이러한 변화양상에 있어서 선학들의 연구 방법 및 그 결과의 다양성이 존재하였다. 본 연구에서는 Doppler ultrasound를 이용하여, 교정치료 전과 교정치료 시작 3주, 6주 후 치수 혈류량의 연속적인 변화를 알아보고자 하였다. 만 15세 이상 환자 18명을 연구대상으로 Doppler ultrasound를 이용하여 상, 하악 6전치 중 경도의 총생(2 mm 미만)을 보이는 치아(총생측정: required space-available space)와 인접치아를 포함한 3개의 치아를 대상으로 치수 혈류량의 변화를 알아보았다. 연구결과 부위별(상, 하악), 치아별, 기간에 따른 치수 혈류량의 변화는 교정 치료 시작 전과 시작 후 3주, 6주 혈류량에 유의한 차이가 없었다. 또한 치수 생활력 상실의 내재적 위험성을 비교하고자 교정 치료 시작 전 치아별로 치수혈류량을 비교하였을 때, 상악에서는 측절치, 하악에서는 견치에서 통계학적으로 유의한 차이는 나타나지 않았지만, 모든 항목에서 적은 값을 나타냈다 (p > 0.05). 본 연구의 결과는 이후에 진행될 Doppler ultrasound의 치아이동유형, 환자의 연령을 고려한 세부적인 실험 시 방법론적인 기초 자료로서 뿐만 아니라, 교정치료 시 치수 생활력의 상실에 대한 참고 자료가 될 수 있을 것이다.

비침습적 초음파 조직 탄성도 측정 시스템 개발 (Development of a Non-invasive Ultrasonic Measurement System for tissue elasticity)

  • 이균정;최우혁;유재원;서종범;최서형;신태민
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.469-475
    • /
    • 2009
  • Diseases caused by indurate tissues of the internal organs are liver cirrhosis and abdominal sclerosis. The cause of chronic gastro-intestinal disease is a digestive system disorder and a defecation disorder. They impede peristaltic movement and digestive system with the symptom that indurate tissues. The purpose of the present study was to determine the disease grade quantitatively by measuring an indurated standard of tissues and organs. For the measurement of elasticity, we designed the system that measure the displacement of the substance and approved pressure using ultrasound transducer. For verification of developed system, we compared elasticity as results of experiment between the developed system and public elasticity measurement machine at individual plastic phantoms made by plastic hardener and softener. Elasticity of the plastic phantoms is averagely 0.007MPa lower measured by developed system than Micro-indenter, and less than 10% errors. Comparing with economical value and accuracy between developed system and Micro-indenter, the system is significant of measurement for tissue elasticity. Thus, it is possible to measure a elasticity at human tissue and organ. A chronic gastro-disease as well as grade could be decided objective validity using this system.

뜸 자극용 초음파 치료기기의 음향렌즈 설계를 위한 초음파 집속 특성 연구 (Study of Focusing Characteristics of Ultrasound for Designing Acoustic Lens in Ultrasonic Moxibustion Device)

  • 배재현;송성진;김학준;김기복
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.134-140
    • /
    • 2015
  • 전통적인 뜸 요법은 시술자의 주관적이고 정성적인 치료로 인해 환자의 피부에 강한 열 자극이 가해져 심한 통증을 주거나 화상을 입히는 문제점을 갖고 있다. 이러한 한계를 극복하기 위한 대안으로 객관성과 정량화가 가능한 초음파를 활용한 뜸 자극 치료기술이 주목받고 있다. 하지만, 초음파 에너지를 열에너지로 변환하기 위해서는 초음파 치료기기의 음향렌즈에 따른 초음파 집속 특성 분석이 필요하다. 따라서, 본 논문에서는 초음파 집속 특성에 영향을 주는 음향렌즈의 형태(오목렌즈, 계단형 렌즈)에 따른 집속 시뮬레이션을 통해 각 렌즈의 음압 분포, 음압의 크기, 초점의 위치를 계산하였으며, 설계한 렌즈를 제작하여 음압 측정 실험을 통해 음향렌즈의 집속 성능을 검증하였다.

발목 근 피로 시 테이핑, 스트레칭 그리고 초음파 중재가 융합적 균형에 미치는 효과 (The Effect of Taping, Stretching and Ultrasound Intervention on Convergent Balance with Ankle Muscle Fatigue)

  • 유은정;이수영
    • 한국융합학회논문지
    • /
    • 제9권10호
    • /
    • pp.141-147
    • /
    • 2018
  • 본 연구의 목적은 유도된 발목 근피로 시 테이핑, 스트레칭 그리고 초음파가 융합적 균형능력에 미치는 효과를 알아보는 데 있다. 건강한 성인 남녀 39명이 본 연구에 자발적으로 참여하였다. 발목 근피로 유발 이후 대상자들은 테이핑, 정적 스트레칭 또는 초음파 그룹으로 무작위 선정되었다. 그리고 각 그룹에 해당하는 중재방법이 적용되었다. 균형 능력은 Space Balance 3D를 이용하여 발목 근피로 전과 후 그리고 중재 후에 측정되었다. 균형능력은 그룹 간 유의한 차이는 없었지만(p>.05), 그룹 내 모두에서 유의하게 증가하였다(p<.001). 그러므로 발목 근 피로에 테이핑, 정적 스트레칭 그리고 초음파는 융합적 균형능력에 효과적일 것이다. 향후 연구에서는 다양한 측정변수 측정과 치료적 중재를 적용하여 치료적 효과를 증명할 필요가 있다.