• Title/Summary/Keyword: Ultrasound measurement

Search Result 328, Processing Time 0.026 seconds

The Duplicate Effect of Thread-embedding Therapy on 5 Patients with Obesity (비만치료를 위한 매선요법의 중복시술 효과 5례)

  • Shin, Hwa-Young;Lim, Seong-Chul;Lee, Yun-Kyu;Kwon, Hyo-Jung;Jung, Tae-Young;Lee, Bong-Hyo;Kim, Jae-Su
    • Journal of Acupuncture Research
    • /
    • v.29 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the duplicate effect of thread-embedding therapy against obesity. Methods : 5 women from 20 to 30 with obesity were treated with thread-embedding therapy and compared the results with physical measurement, body composition tests and fat thickness measured by ultrasound. Results : The thread-embedding therapy locally reduced body size and fat thickness and had a cumulative effect, but showed the greatest effect in the abdominal region. It didn't affect to the overall change of body composition. Conclusions : The duplicate procedure of thread-embedding therapy for obesity had a cumulative effect, but it depended on the treatment region.

Effect of Cervical Manipulation on Blood Velocity and Flow in Subjects with Asymmetric Vertebral Artery (경추 도수교정이 추골동맥 비대칭군의 혈류속도와 혈류량에 미치는 영향)

  • Kim, Han-Il;Kim, Ho-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Background: The purpose of this study was to identify the effects of cervical manipulation for improve blood velocity and flow in the subjects with asymmetric vertebral artery. Methods: Twenty-four subjects on asymmetric vertebral artery with right side have less blood flow than left side participated in this study for apply to non-specific cervical manipulation on lower portion. Measurement method were using duplex ultrasound with colour doppler imaging for blood velocity and flow on left and right vertebral artery. Results: Compared changes of blood velocity and flow on unilateral after the cervical manipulation, the left blood velocity decreased significantly (p<.01) and the right blood velocity increased significantly (p<.01). The left blood flow no significant changes and the right blood flow increased significantly (p<.01). Compared changes of blood velocity and flow on bilateral, the left and right blood velocity and flow made significantly difference on pre-manipulation (p<.01). However, both side no significantly difference on post-manipulation. Conclusions: These findings suggest that the non-specific cervical manipulation took effect for improve blood velocity and flow in the subjects with asymmetric vertebral artery. Therefore, therapeutic approaches for improve to asymmetric vertebral artery should be consider non-specific cervical manipulation.

  • PDF

Usefulness of ultrasound contrast media for cardiac output measurement with echocardiography

  • Yun, Je Woong;Yeon, Seong Chan;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.1
    • /
    • pp.47-52
    • /
    • 2015
  • The purpose of this study was to determine if contrast media would enhance visualization of the endocardium for assessment of left ventricle (LV) function. In addition, differences between pre- and post-contrast evaluation for the cardiac output measurements including the modified Simpson's method and automated contour tracking (ACT) method were examined. Ten clinically healthy adult beagle dogs (three males and seven females) between 2~3 years old and weighing 6.6~10.8 kg were used. Echocardiographic examinations were performed to compare pre- and post-contrast LV endocardium visualization using a segmental scoring method. Two different methods for measuring cardiac output were also compared. LV visualization was significantly enhanced in post-contrast echocardiography (p < 0.01). Significant differences between pre- and post-contrast measurements for the modified Simpson's method (p < 0.05) were also observed. No significant difference was found for the ACT method. Contrast echocardiography provides better LV chamber opacification and significantly improves wall segment visualization. Furthermore, contrast echocardiography for measuring cardiac output is helpful for the modified Simpson's method.

The Influence of Microcurrent on Pain and Function of Patients with Chronic Back Pain (만성 요통 환자에게 미세전류의 적용이 통증 및 기능에 미치는 영향)

  • Park, Jang-Sung;Jung, Hwa-Su
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • Purpose : This research inquires into the effect of applying microcurrent (MC) according to various frequency levels on the pain and functional recovery of patients with chronic back pain. Methods : Thirty participants with chronic lower back pain disease were divided equally into three experimenta l groups. The MC frequency used in the first experimental group was 0.5Hz, the second experimental group was 50Hz, and the third experimental group was 100Hz for 20 minute sessions. A hot pack and ultrasound were applied to all groups as the general physical therapy. Measurements were taken using the visual analogue scale (VAS), the face pain rating scale (FPRS), and the Oswestry disability index (001). The analysis used the paired t-test in order to compare pretest and posttest results. A one-way ANOVA was performed to make comparisons with regards to frequency levels. Results : VAS, FPRS, and 001 showed significant pain decrease in all groups except for the 001 measurement in the 0.5 Hz group. There were no significant differences according to frequency levels. Conclusion: For chronic pain and functional recovery, a microcurrent produces an effect after treatment. However, results did not show a significant difference in change obtained from differing frequency levels.

Effect of Blood Flow on Carotid and Vertebral Artery During Forward Shift on Head: Case Study (머리의 전방 이동이 경동맥과 추골동맥 혈류량의 변화에 미치는 영향: 사례연구)

  • Ko, Do-hoon;Kim, Han-il;Kim, Myung-joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.43-47
    • /
    • 2015
  • Background: The purpose of this study was to identify the effects of the blood flow on carotid and vertebral artery during the forward shift on head. Methods: A 20-year female healthy subject participated in this study. This study was set up the forward shift on head at the 3cm and 6cm in a shoulder midline (acromion). Measurement method were using duplex ultrasound with colour doppler imaging for the blood flow on carotid and vertebral artery. Results: Carotid artery was increased the blood flow and vertebral artery was decreased the blood flow during forward shift on head. Conclusions: These findings suggest that carotid and vertebral artery changes to the blood flow during forward shift on head. Therefore, we should be consider that hemodynamic factor when apply to the therapeutic exercise for patients of forward head posture.

  • PDF

Ultrasonic Approach of Rayleigh Pitch-catch Contact Ultrasound Waves on CFRP Laminated Composites

  • Yang, In-Young;Im, Kwang-Hee;Heo, Uk;Hsu, David K.;Sim, Jae-Ki;Kim, Hak-Joon;Song, Sung-Jin
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.209-211
    • /
    • 2007
  • 최근에는 탄소섬유강화복합재료(CFRP)는 우수한 기계적인 물성치와 수월한 설계특성으로 인해 우주.민간 항공산업분야 뿐만 아니라 여러분야에 응용성이 매우 높다. 그러나 CFRP 복합적층판으로 제작된 구조물은 충격손상을 받을 시에는 50-75%치 강도가 낮아지는 취약성을 가지고 있다. 따라서 본 연구에는 CFRP복합재의 구조건전성 및 결함여부를 비파괴적으로 검사 및 탐상을 하기 위해서 시도하였다. 특히, C-scanner의 수침조에서 충격손상을 받은 시험편을 집어넣어 자동 데이터 획득 시스템을 구동하여 현장응용성이 가장 높은 일 방향 초음파측정 (one-sided ultrasonic measurement) 방법인 평가기법을 제안하였다. 본 연구에서 제안한 일방향 초음파 피치캐치방법이 CFRP 복합적층판내에서 일반 수직 초음파 탐상기법보다 훨씬 민감함을 알 수 있었다.

Case Study of Application on ADIM of Patient With Chronic Low Back Pain for Contraction Training of Transversus Abdominis (만성요통환자의 복횡근 수축훈련을 위한 ADIM 적용사례)

  • Kim, Han-Il
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.49-55
    • /
    • 2011
  • Background: The purpose of this study was to identify the effects of the abdominal drawing-in maneuver (ADIM) for contraction training of transversus abdominis (TrA) to the patient with chronic low back pain (CLBP). Methods: A 37-year female patient with CLBP participated in study. This study was fix to method of ADIM that maintain to draw in lower abdomen in sitting position on chair and fix 1 time protocol that perform rest for 1-min and ADIM for 1-min during 10-min. Hereunder the subject performed 2 times protocol during 30-min. Measurement method were visual analogue scale (VAS), Korean version of Oswestry disability index (KODI) and using ultrasound imaging. Results: VAS was decreased 5cm to 1cm after intervention 3 weeks, KODI was decreased 22% to 9% after intervention 3 weeks and changes in thickness of the TrA were increased 32% to 68% during ADIM. Conclusions: These findings suggest that performed the ADIM took effect for decreased pain and functional disability level with increased changes in thickness of the TrA. Therefore, patients with CLBP should be use for training of deep abdominal muscles apply to the ADIM.

  • PDF

A study on ultrasound analysis of the transformer strange signal (변압기 이상음의 초음파 분석에 관한 연구)

  • 백화종;지석근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.835-838
    • /
    • 2002
  • A running high voltage equipments produce ultrasonic wave that has unique sound by the specific characteristics of the electricity. The generation of the ultrasonic wave is made by the electric transform like arcing, corona, and tracking so on. The mechanical losses and fatal human damages are happened by the electric failure of high voltage equipments. To prevent and diagnose the obstacle factors of the high voltage equipments, the measurement of the ultrasonic wave became to be prominent. However standardized data have been a deficient situation by now. This paper measures the ultrasonic wave coming from the real running transformer equipments and transforms it as an audio frequency. Measured data represents as frequency and time domain through the FFT(Fast Fourier Transform) transform. In conclusion, the purpose of this paper is to standardize the analyzed data.

  • PDF

The activity of factor VIII and IX of cord blood at mid-trimester in fetuses without hemophilia

  • Choe, David Kwang Yong;Oh, Jeong Won;Jun, Jong Kwan;Choi, Young Min
    • Journal of Genetic Medicine
    • /
    • v.13 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Purpose: Molecular genetic analysis is the main approach used for prenatal diagnosis of hemophilia A and B. However, in certain cases, such analysis is uninformative. In such situations, direct measurement of fetal coagulation factor levels is still the best option, and it may be the only option in some cases. This study was conducted to determine the normal ranges of mid-trimester cord blood factor VIII (FVIII) and IX (FIX) in a Korean population. Materials and Methods: Twenty-six FVIII samples and 29 FIX samples were assayed in fetal cord blood acquired by ultrasound-guided cordocentesis. Sampling was conducted during gestational ages of 19-24 weeks. Results: The mean and standard deviations for FVIII and FIX activity were $45.5{\pm}30.5%$ and $19.9{\pm}12.2%$, respectively. Ranges for FVIII and FIX were 1.5-125.0% and 6.0-52.0%, respectively. Conclusion: Our study revealed the normal ranges and lowest level of factor VIII and factor IX in non-affected normal fetus by fetal cord blood sampling during the mid-trimester in a Korea population. The factor assay of the fetal cord blood is invasive but feasible and provides important basic data related to hemophilia.

Transrectal Ultrasound Scanning for Detecting the Early Pregnancy in Korean Black Goats

  • Shin, H.G.;Choi, Y.S.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.4
    • /
    • pp.209-212
    • /
    • 2007
  • This study was performed to establish the early pregnancy diagnosis with evaluation of size of embryonic vesicles and change of crown-rump length (CRL) by transrectal ultrasonography in the Korean black goats. Early pregnancy diagnosis was performed in the 114 goats from 19 to 35 days after coitus by transrectal 5.0 MHz transducer. Embryonic vesicles and CRL in the 142 goats from 19 to 42 days was measured to establish the correlation between gestational age and these parameters. The early pregnancy diagnosis achieved 80% accuracy after days 25 and 100% accuracy after days 28 after breeding. Diameters of embryonic vesicle and CRL were significantly increased with the gestational age. In these facts, early pregnancy diagnosis is possible on Days 25 after breeding and measurement of embryonic vesicles and CRL were useful to predict the gestational age in Korean black goat.