DOI QR코드

DOI QR Code

Usefulness of ultrasound contrast media for cardiac output measurement with echocardiography

  • Yun, Je Woong (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Yeon, Seong Chan (Research Institute of Life Sciences, Gyeongsang National University) ;
  • Lee, Hee Chun (Research Institute of Life Sciences, Gyeongsang National University)
  • Received : 2014.11.17
  • Accepted : 2015.01.19
  • Published : 2015.03.31

Abstract

The purpose of this study was to determine if contrast media would enhance visualization of the endocardium for assessment of left ventricle (LV) function. In addition, differences between pre- and post-contrast evaluation for the cardiac output measurements including the modified Simpson's method and automated contour tracking (ACT) method were examined. Ten clinically healthy adult beagle dogs (three males and seven females) between 2~3 years old and weighing 6.6~10.8 kg were used. Echocardiographic examinations were performed to compare pre- and post-contrast LV endocardium visualization using a segmental scoring method. Two different methods for measuring cardiac output were also compared. LV visualization was significantly enhanced in post-contrast echocardiography (p < 0.01). Significant differences between pre- and post-contrast measurements for the modified Simpson's method (p < 0.05) were also observed. No significant difference was found for the ACT method. Contrast echocardiography provides better LV chamber opacification and significantly improves wall segment visualization. Furthermore, contrast echocardiography for measuring cardiac output is helpful for the modified Simpson's method.

Keywords

References

  1. Abbott JA, MacLean HN. Comparison of Doppler-derived peak aortic velocities obtained from subcostal and apical transducer sites in healthy dogs. Vet Radiol Ultrasound 2003, 44, 695-698. https://doi.org/10.1111/j.1740-8261.2003.tb00533.x
  2. Averkiou M, Powers J, Skyba D, Bruce M, Jensen S. Ultrasound contrast imaging research. Ultrasound Q 2003, 19, 27-37. https://doi.org/10.1097/00013644-200303000-00004
  3. Beaulieu KE, Kerr CL, McDonel WN. Evaluation of a lithium dilution cardiac output technique as a method for measurement of cardiac output in anesthetized cats. Am J Vet Res 2005, 66, 1639-1645. https://doi.org/10.2460/ajvr.2005.66.1639
  4. Bennet DH, Rowlands DJ. Test of reliability of echocardiographic estimation of left ventricular dimensions and volumes. Br Heart J 1976, 38, 1133-1139. https://doi.org/10.1136/hrt.38.11.1133
  5. Boon JA. Evaluation of size, function, and hemodynamics. In: Boon JA (ed.). Manual of Veterinary Echocardiography. 2nd ed. pp. 206-207, Wiley-Blackwell, Ames, 2011.
  6. Cohen JL, Cheirif J, Segar DS, Gillam LD, Gottdiener JS, Hausnerova E, Bruns DE. Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent: results of a phase III multicenter trial. J Am Coll Cardiol 1998, 32, 746-752. https://doi.org/10.1016/S0735-1097(98)00311-8
  7. Crouse LJ, Cheirif J, Hanly DE, Kisslo JA, Labovitz AJ Raichlen JS, Schutz RW, Shah PM, Smith MD. Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the phase III albunex multicenter trial. J Am Coll Cardiol 1993, 22, 1494-1500. https://doi.org/10.1016/0735-1097(93)90562-F
  8. Crouse LJ, Kramer PH. Opacification and border delineation improvement in patients with suboptimal endocardial border definition on routine echocardiography: results of a phase III trial of sonicated albumin microspheres. Clin Cardiol 1991, 14 (Suppl 5), V19-22. https://doi.org/10.1002/clc.4960140705
  9. DeMaria AN, Bommer W, Kwan OL, Riggs K, Smith M, Waters J. In vivo correlation of thermodilution cardiac output and videodensitometric indicator-dilution curves obtained from contrast two-dimensional echocardiograms. J Am Coll Cardiol 1984, 3, 999-1004. https://doi.org/10.1016/S0735-1097(84)80359-9
  10. Feigenbaum H, Stone JM, Lee DA, Nasser WK, Chang S. Identification of ultrasound echoes from the left ventricle by use of intracardiac injections of indocyanine green. Circulation 1970, 41, 615-621. https://doi.org/10.1161/01.CIR.41.4.615
  11. Feinstein SB, Cheirif J, Ten Cate FJ, Silverman PR, Heidenreich PA, Dick C, Desir RM, Armstrong WF, Quinones MA, Shah PM. Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results. J Am Coll Cardiol 1990, 16, 316-324. https://doi.org/10.1016/0735-1097(90)90580-I
  12. Goldman ME, Mindich BP. Intraoperative cardioplegic contrast echocardiography for assessing myocardial perfusion during open heart surgery. J Am Coll Cardiol 1984, 4, 1029-1034. https://doi.org/10.1016/S0735-1097(84)80067-4
  13. Grayburn PA, Weiss JL, Hack TC, Klodas E, Raichlen JS, Vannan MA, Klein AL, Kitzman DW, Chrysant SG, Cohen JL, Abrahamson D, Foster E, Perez JE, Aurigemma GP, Panza JA, Picard MH, Byrd BF 3rd, Segar DS, Jacobson SA, Sahn DJ, DeMaria AN. Phase III multicenter trial comparing the efficacy of 2% dodecafluoropentane emulsion (EchoGen) and sonicated 5% human albumin (Albunex) as ultrasound contrast agents in patients with suboptimal echocardiograms. J Am Coll Cardiol 1998, 32, 230-236. https://doi.org/10.1016/S0735-1097(98)00219-8
  14. Hergan K, Schuster A, Fruhwald J, Mair M, Burger R, Topker M. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method. Eur J Radiol 2008, 65, 270-278. https://doi.org/10.1016/j.ejrad.2007.03.031
  15. Hofer CK, Ganter MT, Zollinger A. What technique should I use to measure cardiac output? Curr Opin Crit Care 2007, 13, 308-317. https://doi.org/10.1097/MCC.0b013e3280c56afb
  16. Hozumi T, Yoshida K, Yoshioka H, Yagi T, Akasaka T, Takagi T, Nishiura M, Watanabe M, Yoshikawa J. Echocardiographic estimation of left ventricular cavity area with a newly developed automated contour tracking method. J Am Soc Echocardiogr 1997, 10, 822-829. https://doi.org/10.1016/S0894-7317(97)70042-7
  17. Hundley WG, Kizilbash AM, Afridi I, Franco F, Peshock RM, Grayburn PA. Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging. J Am Coll Cardiol 1998, 32, 1426-1432. https://doi.org/10.1016/S0735-1097(98)00409-4
  18. Kasprzak JD, Paelinck B, Ten Cate FJ, Vletter WB, de Jong N, Poldermans D, Elhendy A, Bouakaz A, Roelandt JR. Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border. Am J Cardiol 1999, 83, 211-217.
  19. Kerber RE, Kioschos JM, Lauer RM. Use of an ultrasonic contrast method in the diagnosis of valvular regurgitation and intracardiac shunts. Am J Cardiol 1974, 34, 722-727. https://doi.org/10.1016/0002-9149(74)90163-5
  20. Kienle RD, Thomas WP. Echocardiography. In: Nyland TG, Mattoon JS (eds.). Small Animal Diagnostic Ultrasound. 2nd ed. pp. 368, Saunders, Pensylvania, 2002.
  21. Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 1984, 70, 425-431. https://doi.org/10.1161/01.CIR.70.3.425
  22. Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T. Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 2004, 44, 1030-1035. https://doi.org/10.1016/j.jacc.2004.05.068
  23. Mor-Avi V, Shroff SG, Robinson KA, Ng AF, Cholley BP, Marcus RH, Lang RM. Effects of left ventricular pressure on sonicated albumin microbubbles: evaluation using an isolated rabbit heart model. J Am Coll Cardiol 1994, 24, 1779-1785. https://doi.org/10.1016/0735-1097(94)90187-2
  24. Nahar T, Croft L, Shapiro R, Fruchtman S, Diamond J, Henzlova M, Machac J, Buckley S, Goldman ME. Comparison of four echocardiographic techniques for measuring left ventricular ejection fraction. Am J Cardiol 2000, 86, 1358-1362. https://doi.org/10.1016/S0002-9149(00)01243-1
  25. Nguyen TT, Dhond MR, Sabapathy R, Bommer WJ. Contrast microbubbles improve diagnostic yield in ICU patients with poor echocardiographic windows. Chest 2001, 120, 1287-1292. https://doi.org/10.1378/chest.120.4.1287
  26. Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993, 40, 142-153. https://doi.org/10.1007/BF03011312
  27. O'Brien RT, Iani M, Matheson J, Delaney F, Young K. Contrast harmonic ultrasound of spontaneous liver nodules in 32 dogs. Vet Radiol Ultrasound 2004, 45, 547-553. https://doi.org/10.1111/j.1740-8261.2004.04094.x
  28. Otterstad JE, Froeland G, St John Sutton M, Holme I. Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. Eur Heart J 1997, 18, 507-513. https://doi.org/10.1093/oxfordjournals.eurheartj.a015273
  29. Parisi AF, Moynihan PF, Feldman CL, Folland ED. Approaches to determination of left ventricular volume and ejection fraction by real-time two-dimensional echocardiography. Clin Cardiol 1979, 2, 257-263. https://doi.org/10.1002/clc.4960020404
  30. Quaia E. Physical basis and principles of action of microbubble-based contrast agents. In: Quaia E (ed.). Contrast Media in Ultrasonography. Basic Principles and Clinical Applications. pp. 15-30, Springer, Berlin, 2005.
  31. Rezende ML, Pypendop BH, Ilkiw JE. Evaluation of transesophageal echo-Doppler ultrasonography for the measurement of aortic blood flow in anesthetized cats. Am J Vet Res 2008, 69, 1135-1140. https://doi.org/10.2460/ajvr.69.9.1135
  32. Rijsterborgh H, Romdoni R, Vletter W, Bom N, Roelandt J. Reference ranges of left ventricular cross-sectional echocardiographic measurements in adult men. J Am Soc Echocardiogr 1989, 2, 415-418. https://doi.org/10.1016/S0894-7317(89)80043-4
  33. Scansen BA, Bonagura JD, Schober KE, Muir WW. Evaluation of a commercial ultrasonographic hemodynamic recording system for the measurement of cardiac output in dogs. Am J Vet Res 2009, 70, 862-868. https://doi.org/10.2460/ajvr.70.7.862
  34. Schober KE, Fuentes VL, Bonagura JD. Comparison between invasive hemodynamic measurements and noninvasive assessment of left ventricular diastolic function by use of Doppler echocardiography in healthy anesthetized cats. Am J Vet Res 2003, 64, 93-103. https://doi.org/10.2460/ajvr.2003.64.93
  35. Spain MG, Smith MD, Grayburn PA, Harlamert EA, DeMaria AN. Quantitative assessment of mitral regurgitation by Doppler color flow imaging: angiographic and hemodynamic correlations. J Am Coll Cardiol 1989, 13, 585-590. https://doi.org/10.1016/0735-1097(89)90597-4
  36. Sugioka K, Hozumi T, Yagi T, Yamamuro A, Akasaka T, Takeuchi K, Homma S, Yishida K, Yoshikawa J. Automated quantification of left ventricular function by the automated contour tracking method. Echocardiography 2003, 20, 313-318. https://doi.org/10.1046/j.1540-8175.2003.03036.x
  37. Thomson HL, Basmadjian AJ, Rainbird AJ, Razavi M, Avierinos JF, Pellikka PA, Bailey KR, Breen JF, Enriques-Sarano M. Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: a prospective, randomly assigned, blinded study. J Am Coll Cardiol 2001, 38, 867-875. https://doi.org/10.1016/S0735-1097(01)01416-4
  38. Wahr DW, Wang YS, Schiller NB. Left ventricular volumes determined by two-dimensional echocardiography in a normal adult population. J Am Coll Cardiol 1983, 1, 863-868. https://doi.org/10.1016/S0735-1097(83)80200-9

Cited by

  1. Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles vol.20, pp.5, 2019, https://doi.org/10.4142/jvs.2019.20.e45